Lucene search
+L

240 matches found

EUVD
EUVD
added 2025/10/03 8:07 p.m.9 views

EUVD-2024-17069

Malicious code in bioql PyPI...

7.5CVSS7.5AI score0.00988EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.12 views

EUVD-2025-16143

Malicious code in bioql PyPI...

7.5CVSS6.8AI score0.07662EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.11 views

EUVD-2025-16123

Malicious code in bioql PyPI...

5.3CVSS6.6AI score0.0028EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.8 views

EUVD-2025-16125

Malicious code in bioql PyPI...

9.8CVSS6.6AI score0.00321EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.11 views

EUVD-2025-16121

Malicious code in bioql PyPI...

9.8CVSS6.8AI score0.00322EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.9 views

EUVD-2025-16127

Malicious code in bioql PyPI...

9.8CVSS6.8AI score0.00476EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.11 views

EUVD-2025-16142

Malicious code in bioql PyPI...

7.5CVSS6.8AI score0.07662EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.12 views

EUVD-2025-16124

Malicious code in bioql PyPI...

5.3CVSS6.6AI score0.0028EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.12 views

EUVD-2025-16122

Malicious code in bioql PyPI...

9.8CVSS6.8AI score0.00322EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/03 8:07 p.m.8 views

EUVD-2025-16131

Malicious code in bioql PyPI...

7.5CVSS6.6AI score0.00255EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2025/08/01 12:00 a.m.13 views

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption within the Niagara Framework, along with the Niagara Enterprise Security tools for access control and security, stems from incorrect processing of alternative data streams. This allows attackers to compromise the confidentiality, integrity, and accessibility of protected information.

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption in the Niagara Framework, along with the access control and security measures, is related to incorrect handling of alternative data streams. Exploiting this...

10CVSS5.8AI score0.00476EPSS
SaveExploits0References5Affected Software2
BDU FSTEC
BDU FSTEC
added 2025/08/01 12:00 a.m.10 views

The vulnerability of the device management platform for systems related to heating, ventilation, and air conditioning, lighting, and energy consumption within the Niagara Framework, as well as the Niagara Enterprise Security tools for access control and security, stems from the absence of necessary encryption steps. This allows attackers to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the device management platform for systems for heating, ventilation, and air conditioning, lighting, and energy consumption, as well as the Niagara Framework and the access control and security measures, is related to the absence of the necessary encryption step. Exploiting...

10CVSS5.8AI score0.00322EPSS
SaveExploits0References5Affected Software2
BDU FSTEC
BDU FSTEC
added 2025/08/01 12:00 a.m.10 views

The vulnerability of the device management platform for systems related to heating, ventilation, and air conditioning, lighting, and energy consumption within the Niagara Framework, as well as the Niagara Enterprise Security tools for access control and security, stems from the ability to disclose information through a query string, allowing attackers to compromise the confidentiality of protected information.

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption, as well as the Niagara Framework and its access control and security measures, is related to the disclosure of information through query strings. Exploitin...

7.8CVSS5.8AI score0.07662EPSS
SaveExploits0References5Affected Software2
BDU FSTEC
BDU FSTEC
added 2025/07/29 12:00 a.m.11 views

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption control within the Niagara Framework, along with the Niagara Enterprise Security tools for access control and security, can be exploited due to improper handling of argument separators in commands. This allows attackers to trigger service failures.

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption control within the Niagara Framework, along with the access control and security measures, is related to improper elimination of argument separators in the...

9CVSS5.8AI score0.00601EPSS
SaveExploits0References4Affected Software2
BDU FSTEC
BDU FSTEC
added 2025/07/29 12:00 a.m.12 views

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption within the Niagara Framework, along with the access control and security measures of Niagara Enterprise Security, arises from the improper assignment of permissions to critical resources. This allows attackers to compromise the confidentiality, integrity, and accessibility of protected information.

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption control within the Niagara Framework, along with the access control and security measures of Niagara Enterprise Security, is related to the incorrect...

10CVSS8AI score0.00371EPSS
SaveExploits0References5Affected Software2
BDU FSTEC
BDU FSTEC
added 2025/07/29 12:00 a.m.12 views

The vulnerability of the device management platform for systems involving heating, ventilation, and air conditioning, lighting, and energy consumption within the Niagara Framework, along with the Niagara Enterprise Security tools for access control and security, stems from incorrect assignment of permissions to critical resources. This allows attackers to gain unauthorized access to protected information, enhance their privileges, and execute arbitrary code.

The vulnerability of the device management platform for heating, ventilation, and air conditioning systems, lighting, and energy consumption control within the Niagara Framework, along with the access control and security measures, is related to the lack of proper protection for the...

9CVSS6.1AI score0.00486EPSS
SaveExploits0References4Affected Software2
BDU FSTEC
BDU FSTEC
added 2025/07/29 12:00 a.m.26 views

The vulnerability of the device management platform for systems involving heating, ventilation, and air conditioning, lighting, and energy consumption within the Niagara Framework, along with the Niagara Enterprise Security tools for access control and security, stems from insufficient calculation of password hashes. This allows attackers to gain access to the device.

The vulnerability of the device management platform for systems involving heating, ventilation, and air conditioning, lighting, and energy consumption, as well as the Niagara Framework and the access control and security measures, is related to insufficient calculation of password hashes...

10CVSS7.9AI score0.0032EPSS
SaveExploits0References5Affected Software2
The Hacker News
The Hacker News
added 2025/07/28 4:12 a.m.22 views

Critical Flaws in Niagara Framework Threaten Smart Buildings and Industrial Systems Worldwide

Cybersecurity researchers have discovered over a dozen security vulnerabilities impacting Tridium's Niagara Framework that could allow an attacker on the same network to compromise the system under certain circumstances. "These vulnerabilities are fully exploitable if a Niagara system is...

9.8CVSS8.2AI score0.07662EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2025/05/22 4:20 p.m.12 views

CVE-2020-14483

A timeout during a TLS handshake can result in the connection failing to terminate. This can result in a Niagara thread hanging and requires a manual restart of Niagara Versions 4.6.96.28, 4.7.109.20, 4.7.110.32, 4.8.0.110 and Niagara Enterprise Security Versions 2.4.31, 2.4.45, 4.8.0.35 to corre...

4.3CVSS6.8AI score0.0042EPSS
SaveExploits0
OSV
OSV
added 2025/05/22 1:15 p.m.9 views

CVE-2025-3944

Incorrect Permission Assignment for Critical Resource vulnerability in Tridium Niagara Framework on QNX, Tridium Niagara Enterprise Security on QNX allows File Manipulation. This issue affects Niagara Framework: before 4.14.2, before 4.15.1, before 4.10.11; Niagara Enterprise Security: before...

9.8CVSS5.8AI score0.00486EPSS
SaveExploits0References2