Lucene search
+L

1034 matches found

Prion
Prion
added 2020/06/29 2:15 p.m.17 views

Hardcoded credentials

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings...

3.6CVSS5.8AI score0.00247EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.29 views

CVE-2020-12035

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings...

5.1AI score0.00247EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:49 p.m.62 views

CVE-2020-12035

CVE-2020-12035 affects Baxter PrismaFlex (all versions) and PrisMax (all versions prior to 3.x). Root cause is a hard-coded service password that grants access to biomedical information, device settings, calibration settings, and network configuration, enabling an attacker to modify device settin...

4.9CVSS5.1AI score0.00247EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2020/06/29 1:45 p.m.68 views

CVE-2020-12039

CVE-2020-12039 affects Baxter Sigma Spectrum Infusion System v6.x (35700BAX) and v8.x (35700BAX2); hard-coded passwords entered via keypad grant access to biomedical menus, including device settings, calibration values, and WBM network configuration. This is a local/physical-access issue with pub...

2.4CVSS4.1AI score0.00333EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:45 p.m.29 views

CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

3.8AI score0.00333EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.13 views

Baxter Sigma Spectrum Infusion System and Spectrum Infusion System Trust Management Issues Vulnerabilities

The Baxter Sigma Spectrum Infusion System and the Baxter Spectrum Infusion System are both infusion pumps from Baxter, Inc. A trust management issue vulnerability exists in the Baxter Sigma Spectrum Infusion System version 6.x model 35700BAX and the Baxter Spectrum Infusion System version 8.x mod...

2.4CVSS6.8AI score0.00333EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/04 4:15 p.m.20 views

CVE-2020-9462

An issue was discovered in all Athom Homey and Homey Pro devices up to the current version 4.2.0. An attacker within RF range can obtain a cleartext copy of the network configuration of the device, including the Wi-Fi PSK, during device setup. Upon success, the attacker is able to further...

4.3CVSS4.7AI score0.00317EPSS
SaveExploits0References1
Prion
Prion
added 2020/06/04 4:15 p.m.20 views

Design/Logic Flaw

An issue was discovered in all Athom Homey and Homey Pro devices up to the current version 4.2.0. An attacker within RF range can obtain a cleartext copy of the network configuration of the device, including the Wi-Fi PSK, during device setup. Upon success, the attacker is able to further...

3.3CVSS4.7AI score0.00317EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2020/06/04 3:49 p.m.30 views

CVE-2020-9462

An issue was discovered in all Athom Homey and Homey Pro devices up to the current version 4.2.0. An attacker within RF range can obtain a cleartext copy of the network configuration of the device, including the Wi-Fi PSK, during device setup. Upon success, the attacker is able to further...

4.7AI score0.00317EPSS
SaveExploits0References1
NVD
NVD
added 2020/05/14 5:15 p.m.14 views

CVE-2019-13022

Bond JetSelect all versions has an issue in the Java class ENCtool.jar and corresponding password generation algorithm used to set initial passwords upon first installation. It XORs the plaintext into the 'encrypted' password that is then stored within the database. These steps are able to be...

10CVSS7.5AI score0.01306EPSS
SaveExploits1References1
Prion
Prion
added 2020/05/14 5:15 p.m.16 views

Design/Logic Flaw

Bond JetSelect all versions has an issue in the Java class ENCtool.jar and corresponding password generation algorithm used to set initial passwords upon first installation. It XORs the plaintext into the 'encrypted' password that is then stored within the database. These steps are able to be...

10CVSS7.7AI score0.01306EPSS
SaveExploits2References1
Virtuozzo
Virtuozzo
added 2020/04/29 12:00 a.m.69 views

Product release: Virtuozzo Infrastructure Platform 3.5 Update 3 (3.5.3-18)

This update provides bug fixes and improvements. Vulnerability id: VSTOR-33034 Assigning tier 0 to a cache disk makes no effect. The disk does not receive the "journaltier" parameter and can be used by storage disks of other tiers. Vulnerability id: VSTOR-33032 S3 cluster creation fails with a...

2.2AI score
SaveExploits0
Citrix
Citrix
added 2020/04/14 12:00 a.m.10 views

Error: "The operation could not be performed because a redo log is enabled on the Pool"

After upgradingSDX to 12.0 build, the user is gettingerror while trying to configure network settings for XenServer using LOM...

7.1AI score
SaveExploits0
CNVD
CNVD
added 2020/04/08 12:00 a.m.11 views

Synergy Systems & Solutions HUSKY RTU 6049-E70 Access Control Error Vulnerability (CNVD-2020-25373)

Synergy Systems & Solutions HUSKY RTU 6049-E70 is a Remote Terminal Unit RTU from Synergy Systems & Solutions, India. The Synergy Systems & Solutions HUSKY RTU 6049-E70 is vulnerable to an access control error that can be exploited by an attacker to view the network configuration via SNMP...

5.3CVSS6.9AI score0.00898EPSS
SaveExploits0References1
NVD
NVD
added 2020/04/02 5:15 p.m.17 views

CVE-2020-8423

A buffer overflow in the httpd daemon on TP-Link TL-WR841N V10 firmware version 3.16.9 devices allows an authenticated remote attacker to execute arbitrary code via a GET request to the page for the configuration of the Wi-Fi network...

9CVSS7.5AI score0.09345EPSS
SaveExploits1References2
Talos
Talos
added 2020/03/09 12:00 a.m.188 views

WAGO PFC200 iocheckd service "I/O-Check" cache Multiple Code Execution Vulnerabilities

Summary An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service “I/O-Check” functionality of WAGO PFC 200. A specially crafted XML cache file written to a specific location on the device can cause a stack buffer overflow, resulting in code execution. An...

7.8CVSS6.8AI score0.00656EPSS
SaveExploits3
NVD
NVD
added 2020/02/25 4:15 p.m.25 views

CVE-2019-5142

An exploitable command injection vulnerability exists in the hostname functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted entry to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker ca...

9CVSS7.3AI score0.06625EPSS
SaveExploits1References1
Prion
Prion
added 2020/02/25 4:15 p.m.36 views

Command injection

An exploitable command injection vulnerability exists in the hostname functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted entry to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker ca...

9CVSS7.2AI score0.06625EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2020/02/25 3:28 p.m.84 views

CVE-2019-5142

CVE-2019-5142 affects the Moxa AWK-3131A Series (firmware v1.13). The vulnerability is an OS command injection in the WAP hostname handling: a specially crafted entry to network configuration information can cause arbitrary system commands to execute, giving an attacker full control of the device...

9CVSS7.1AI score0.06625EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
added 2020/02/25 3:28 p.m.34 views

CVE-2019-5142

An exploitable command injection vulnerability exists in the hostname functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted entry to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker ca...

7.2CVSS7.1AI score0.06625EPSS
SaveExploits1References1
Rows per page