15 matches found
CVE-2025-59693
The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allows a physically proximate attacker to obtain debug access and escalate privileges by bypassing the tamper label and opening the chassis without leaving evidence, and accessing th...
CVE-2025-59703
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from t...
EUVD-2025-200271
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow an attacker to gain access the the BIOS menu because is has no password...
CVE-2025-59703
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from t...
CVE-2025-59703
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from t...
EUVD-2025-200252
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components...
CVE-2025-59695
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a user with OS root access to alter firmware on the Chassis Management Board without Authentication. This is called F04...
CVE-2025-59701
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to read and modify the Appliance SSD contents because they are unencrypted...
CVE-2025-59700
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with root access to modify the Recovery Partition because of a lack of integrity protection...
PT-2025-48692
Name of the Vulnerable Software and Affected Versions Entrust nShield Connect XC versions through 13.6.11 Entrust nShield 5c versions through 13.6.11 Entrust nShield HSMi versions through 13.6.11 Entrust nShield Connect XC version 13.7 Entrust nShield 5c version 13.7 Entrust nShield HSMi version...
EUVD-2025-200253
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to read and modify the Appliance SSD contents because they are unencrypted...
CVE-2025-59698
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, might allow a physically proximate attacker to gain access to the EOL legacy bootloader...
PT-2025-48701
Name of the Vulnerable Software and Affected Versions Entrust nShield Connect XC versions through 13.6.11 Entrust nShield 5c versions through 13.6.11 Entrust nShield HSMi versions through 13.6.11 Entrust nShield Connect XC version 13.7 Entrust nShield 5c version 13.7 Entrust nShield HSMi version...
CVE-2025-59702
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components...
CVE-2025-59703
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from t...