Lucene search
K

12 matches found

RedhatCVE
RedhatCVE
added 2025/12/03 5:2 p.m.1 views

CVE-2025-59701

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to read and modify the Appliance SSD contents because they are unencrypted...

4.1CVSS6.8AI score0.00016EPSS
Exploits1References1
RedhatCVE
RedhatCVE
added 2025/12/03 5:1 p.m.3 views

CVE-2025-59702

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components...

7.2CVSS6.9AI score0.00035EPSS
Exploits1References1
EUVD
EUVD
added 2025/12/02 3:30 p.m.2 views

EUVD-2025-200254

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with root access to modify the Recovery Partition because of a lack of integrity protection...

6.4AI score0.00003EPSS
Exploits1References3
OSV
OSV
added 2025/12/02 3:15 p.m.2 views

CVE-2025-59696

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker to modify or erase tamper events via the Chassis management board...

3.2CVSS5.8AI score0.00142EPSS
Exploits8References2
CVE
CVE
added 2025/12/02 12:0 a.m.6 views

CVE-2025-59705

CVE-2025-59705 affects Entrust nShield Connect XC, nShield 5c, and nShield HSMi up to 13.6.11 or 13.7. The issue is a privilege-escalation path via enabling the USB interface by inserting a chassis probe during system boot, described as "Unauthorized Reactivation of the USB interface" (F01). The ...

6.8CVSS6.5AI score0.00041EPSS
Exploits1References2Affected Software1
CVE
CVE
added 2025/12/02 12:0 a.m.8 views

CVE-2025-59697

Entrust nShield devices are affected: Connect XC, nShield 5c, and nShield HSMi up to v13.6.11 and 13.7 allow a physically proximate attacker to escalate privileges by editing the Legacy GRUB bootloader configuration to boot a root shell on host OS start (F06). The underlying issue is a boot-time ...

7.2CVSS6.8AI score0.00035EPSS
Exploits1References2Affected Software1
CVE
CVE
added 2025/12/02 12:0 a.m.8 views

CVE-2025-59702

Affected products: Entrust nShield Connect XC, nShield 5c, and nShield HSMi up to and including version 13.6.11, and version 13.7. The issue allows a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components. Root cause details are not provid...

7.2CVSS6.5AI score0.00035EPSS
Exploits1References2Affected Software1
Positive Technologies
Positive Technologies
added 2025/12/02 12:0 a.m.2 views

PT-2025-48707

Name of the Vulnerable Software and Affected Versions Entrust nShield Connect XC versions through 13.6.11 Entrust nShield 5c versions through 13.6.11 Entrust nShield HSMi versions through 13.6.11 Entrust nShield Connect XC version 13.7 Entrust nShield 5c version 13.7 Entrust nShield HSMi version...

7.8CVSS7AI score0.00006EPSS
Exploits1References7
CVE
CVE
added 2025/12/02 12:0 a.m.5 views

CVE-2025-59701

Summary: CVE-2025-59701 affects Entrust nShield Connect XC, nShield 5c, and nShield HSMi up to version 13.6.11 or 13.7. The vulnerability arises because the Appliance SSDs are unencrypted, allowing a physically proximate attacker with elevated privileges to read and modify SSD contents. The avail...

4.1CVSS6.4AI score0.00016EPSS
Exploits1References2Affected Software1
Vulnrichment
Vulnrichment
added 2025/12/02 12:0 a.m.3 views

CVE-2025-59704

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow an attacker to gain access the the BIOS menu because is has no password...

6.8AI score0.00006EPSS
Exploits1References2
Positive Technologies
Positive Technologies
added 2025/12/02 12:0 a.m.3 views

PT-2025-48695

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, might allow a physically proximate attacker to gain access to the EOL legacy bootloader...

7.1AI score0.00041EPSS
Exploits1References3
Cvelist
Cvelist
added 2025/12/02 12:0 a.m.4 views

CVE-2025-59701

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to read and modify the Appliance SSD contents because they are unencrypted...

0.00016EPSS
Exploits1References2
Rows per page
Query Builder