28 matches found
EUVD-2018-7358
Malware in sbrugna...
EUVD-2018-7355
Malware in sbrugna...
EUVD-2018-7356
Malware in sbrugna...
EUVD-2018-7354
Malware in sbrugna...
EUVD-2018-7357
Malware in sbrugna...
CVE-2018-15476
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The SSL/TLS server certificate in the device to cloud communication...
CVE-2018-15477
myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...
CVE-2018-15476
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The SSL/TLS server certificate in the device to cloud communication...
CVE-2018-15479
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. Devices did not authenticate themselves to the cloud in device to...
CVE-2018-15480
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated...
CVE-2018-15477
myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...
CVE-2018-15478
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based o...
CVE-2018-15479
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. Devices did not authenticate themselves to the cloud in device to...
CVE-2018-15478
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based o...
CVE-2018-15480
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated...
Design/Logic Flaw
myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device...
Authentication flaw
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. Devices did not authenticate themselves to the cloud in device to...
Design/Logic Flaw
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated...
CVE-2018-15477
The CVE set concerns myStrom WiFi Switch family with multiple issues in 2018. CVE-2018-15477 (and related CVEs 15476–15480) describe: a command-injection and OS-command execution risk in MyStrom devices where an unsanitized cloud parameter could be used to run commands on the device; affected: my...
CVE-2018-15476
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The SSL/TLS server certificate in the device to cloud communication...