added 2025/10/07 12:30 a.m.4 views

EUVD-2018-20478

Malware in sbrugna...

7.2CVSS6.6AI score0.00362EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.4 views

EUVD-2018-20476

Malware in sbrugna...

6.9CVSS6.5AI score0.00333EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/03 8:7 p.m.4 views

EUVD-2025-22480

Malicious code in bioql PyPI...

6.8CVSS6.6AI score0.0027EPSS
Exploits0References1
ATTACKERKB
ATTACKERKB
added 2025/07/24 3:26 a.m.3 views

CVE-2025-4394

Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS5.9AI score0.00188EPSS
Exploits0References4
CNNVD
CNNVD
added 2025/07/24 12:0 a.m.3 views

Medtronic MyCareLink Patient Monitor 安全漏洞

Medtronic MyCareLink Patient Monitor is an open source monitoring system for remote patient monitoring from Medtronic in the United States. A security vulnerability exists in Medtronic MyCareLink Patient Monitor versions prior to 2025.6.25, which stems from the use of an empty password for the...

6.8CVSS6.8AI score0.0027EPSS
Exploits0References1
CVE
CVE
added 2019/03/25 9:26 p.m.73 views

CVE-2019-6538

CVE-2019-6538 concerns Medtronic Conexus radio telemetry protocol lacking authentication/authorization. Connected sources (ICS advisory and coverage) specify the affected devices include MyCareLink Monitor (versions 24950/24952), CareLink Monitor (2490C), CareLink 2090 Programmer, and multiple Me...

9.3CVSS6.4AI score0.00844EPSS
Exploits0References2Affected Software1
CNVD
CNVD
added 2019/03/25 12:0 a.m.3 views

Access Control Error Vulnerability in Multiple Medtronic Products

MyCareLink Monitor and others are products developed by Medtronic. An Access Control Error vulnerability exists in multiple Medtronic products that stems from a failure of the Conexus telemetry protocol to perform authorization or authentication, which could be exploited by an attacker to inject,...

9.3CVSS7AI score0.00844EPSS
Exploits0References1
CNVD
CNVD
added 2019/03/25 12:0 a.m.3 views

Access Control Error Vulnerability in Multiple Medtronic Products (CNVD-2019-09066)

MyCareLink Monitor and others are products developed by Medtronic. An access control error vulnerability exists in multiple Medtronic products that stems from a failure of the Conexus telemetry protocol to perform encryption, which could be exploited by an attacker to listen in on communications...

6.5CVSS6.9AI score0.00195EPSS
Exploits0References1
BDU FSTEC
BDU FSTEC
added 2018/08/14 12:0 a.m.8 views

The vulnerability of Medtronic MyCareLink Patient Monitor’s medical equipment lies in the storage of passwords in a reversible format, which allows an intruder to disclose protected information.

The vulnerability of Medtronic MyCareLink Patient Monitor relates to the storage of passwords in a reversible format. Exploiting this vulnerability could allow an intruder to disclose protected information...

4.9CVSS5.4AI score0.00361EPSS
Exploits0References3
NVD
NVD
added 2018/07/03 1:29 a.m.25 views

CVE-2018-8870

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...

7.2CVSS6.6AI score0.00362EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2018/07/03 1:29 a.m.4 views

CVE-2018-8870

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...

7.2CVSS5.5AI score0.00362EPSS
Exploits0References3