Lucene search
K

91 matches found

RedhatCVE
RedhatCVE
added yesterday2 views

CVE-2025-4397

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data...

6.8CVSS5.5AI score0.0001EPSS
Exploits0References1
EUVD
EUVD
added 2026/05/07 6:30 p.m.4 views

EUVD-2025-209728

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data...

6.8CVSS5.8AI score0.0001EPSS
Exploits0References5
EUVD
EUVD
added 2026/05/07 6:30 p.m.4 views

EUVD-2025-209726

Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​...

6.8CVSS5.8AI score0.00024EPSS
Exploits0References3
NVD
NVD
added 2026/05/07 4:16 p.m.8 views

CVE-2025-4397

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data...

6.8CVSS0.0001EPSS
Exploits0References4
NVD
NVD
added 2026/05/07 4:16 p.m.9 views

CVE-2025-4386

Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​...

6.8CVSS0.00024EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2026/05/07 3:3 p.m.4 views

CVE-2025-4397

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data...

6.8CVSS5.8AI score0.0001EPSS
Exploits0References5
Vulnrichment
Vulnrichment
added 2026/05/07 3:3 p.m.3 views

CVE-2025-4397 Medtronic MyCareLink Patient Monitor Data Encryption Weakness

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data...

6.8CVSS5.8AI score0.0001EPSS
Exploits0References4
CVE
CVE
added 2026/05/07 3:3 p.m.7 views

CVE-2025-4397

CVE-2025-4397 affects Medtronic MyCareLink Patient Monitor. The issue is that per‑product credentials are stored in a recoverable format, allowing an attacker to use these credentials to modify encrypted drive data. The description indicates physical access as the attack vector and a high impact ...

6.8CVSS5.8AI score0.0001EPSS
Exploits0References4
Vulnrichment
Vulnrichment
added 2026/05/07 3:0 p.m.5 views

CVE-2025-4386 Medtronic MyCareLink Patient Monitor Hardware Debug Port

Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​...

6.8CVSS5.8AI score0.00024EPSS
Exploits0References2
CVE
CVE
added 2026/05/07 3:0 p.m.11 views

CVE-2025-4386

CVE-2025-4386 concerns the Medtronic MyCareLink Patient Monitor, which exposes an internal serial interface that can be accessed by an attacker with physical access to reach a UART login prompt. The CVSSv3.1 vector (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) yields a base score of 6.8 (MEDIUM). The att...

6.8CVSS5.8AI score0.00024EPSS
Exploits0References2
Cvelist
Cvelist
added 2026/05/07 3:0 p.m.27 views

CVE-2025-4386 Medtronic MyCareLink Patient Monitor Hardware Debug Port

Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​...

6.8CVSS0.00024EPSS
Exploits0References2
CNNVD
CNNVD
added 2026/05/07 12:0 a.m.4 views

Medtronic MyCareLink Patient Monitor 安全漏洞

Medtronic MyCareLink Patient Monitor is an open-source monitoring system developed by Medtronic in the United States. The Medtronic MyCareLink Patient Monitor has a security vulnerability, which stems from the use of product credentials stored in a recoverable format. This vulnerability could all...

6.8CVSS5.8AI score0.0001EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2026/05/07 12:0 a.m.6 views

PT-2026-38447

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data...

6.8CVSS5.8AI score0.0001EPSS
Exploits0References5
RedhatCVE
RedhatCVE
added 2026/01/09 9:22 a.m.2 views

CVE-2018-10622

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data...

7.1CVSS7.1AI score0.00075EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-19765

Malware in sbrugna...

9.3CVSS8AI score0.00598EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2018-20476

Malware in sbrugna...

6.9CVSS6.5AI score0.00048EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2018-20478

Malware in sbrugna...

7.2CVSS6.6AI score0.00044EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2020-17874

Malware in sbrugna...

8.8CVSS8.6AI score0.00103EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-17878

Malware in sbrugna...

10CVSS9.2AI score0.01274EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2018-2694

Malware in sbrugna...

7.1CVSS7AI score0.00075EPSS
Exploits0References5
Rows per page