201 matches found
EUVD-2019-8096
Malware in sbrugna...
EUVD-2022-46945
Malicious code in bioql PyPI...
CVE-2022-43975
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
CVE-2022-43976
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...
CVE-2022-43977
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2019-18300
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server can trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290,...
CVE-2019-18297
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with local access to the MS3000 Server and low privileges could gain root privileges by sending specifically crafted packets to a named pipe. Please note that an attacker needs to have local access...
CVE-2019-18312
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server could be able to enumerate running RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this...
CVE-2019-18290
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18291,...
CVE-2019-18307
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290,...
CVE-2022-43977
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2022-43977
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2022-43975
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
CVE-2022-43976
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...
CVE-2022-43976
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...
Authentication flaw
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...
Directory traversal
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
Improper access control
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2022-43977
GE Grid Solutions MS3000 devices are affected (versions before 3.7.6.25p0_3.2.2.17p0_4.7p0). The issue is an access-control flaw in the qconn TCP debug port, allowing unauthenticated network access to the debug interface. The root cause is lack of access control on the debug port, per multiple so...