77 matches found
CVE-2019-18296
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This...
CVE-2019-18305
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290,...
CVE-2019-18291
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290,...
CVE-2019-18297
CVE-2019-18297 affects Siemens SPPA-T3000 MS3000 Migration Server (all versions). An attacker with local access and low privileges can gain root privileges by sending specially crafted packets to a named pipe. The vulnerability requires local access to exploit; no public exploits are noted in the...
CVE-2019-18296
Summary: CVE-2019-18296 affects the SPPA-T3000 MS3000 Migration Server (all versions). The issue allows a network-remote attacker to cause a Denial-of-Service and potentially achieve remote code execution by sending specially crafted packets to port 5010/tcp. This vulnerability is stated as indep...
CVE-2019-18294
Affected product : SPPA-T3000 MS3000 Migration Server (All versions). Vulnerability : Denial-of-Service via specially crafted packets sent to port 5010/tcp. Root cause/impact : Processing crafted packets can trigger a DoS condition when the attacker has network access to the MS3000 server. Scope ...
CVE-2019-18293
SPPA-T3000 MS3000 Migration Server (all versions) is affected by CVE-2019-18293. The vulnerability allows a network-accessible attacker to trigger a Denial-of-Service and potentially achieve remote code execution by sending specially crafted packets to port 5010/tcp. Root cause details are not fu...
CVE-2019-18303
Summary (CVE-2019-18303, 18305, 18301, 18302, 18304, 18306, 18307, 18291, 18292, 18294, 18299, 18300, 18304, 18303, 18305, 18301, 18302 – SPPA-T3000 MS3000 Migration Server) : Affected product is the SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access can trigger a ...
CVE-2019-18290
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server All versions. An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18291,...
Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45417)
SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with loc...
Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45411)
SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...
Siemens SPPA-T3000 MS3000 Migration Server File Upload Vulnerability
SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with network access ...
Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45410)
SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...
Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability
SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...
Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability (CNVD-2019-45423)
SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...
Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability
SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...
Siemens SPPA-T3000 (Update A)
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SPPA-T3000 Vulnerabilities: Improper Input Validation, Deserialization of Untrusted Data, Improper Authentication, Cleartext Transmission of Sensitive Information, Unrestricted...