12 matches found
EUVD-2022-46945
Malicious code in bioql PyPI...
CVE-2022-43975
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
CVE-2022-43976
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...
CVE-2022-43977
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2022-43977
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2022-43975
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
CVE-2022-43976
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...
Improper access control
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
Directory traversal
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
CVE-2022-43977
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2022-43975
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
CVE-2022-43976
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...