11747 matches found
Unleashing Agentic AI for Superior Threat-Informed Risk Prioritization with Agent Nyra
The cybersecurity landscape evolves relentlessly, with new adversaries and threats emerging daily. For organizations navigating these challenges, reactive responses are no longer enough. It’s about moving from complex, disconnected data streams to proactive, autonomous solutions with actionable...
Aide security vulnerabilities
Aide is a tool for monitoring file system changes. It can be used to detect unauthorized monitored files and directories. A security vulnerability exists in versions prior to Aide 0.19.2, which stems from improper output neutralization and could lead to bypassing detection...
PT-2025-33108
Name of the Vulnerable Software and Affected Versions: Centreon web versions 23.10.0 through 23.10.26 Centreon web versions 24.04.0 through 24.04.16 Centreon web versions 24.10.0 through 24.10.9 Description: The web application is susceptible to SQL Injection due to improper neutralization of...
EcoStruxure Power Monitoring Expert Deserialization
The vulnerability of the EcoStruxure Power Monitoring Expert and Power Operation software is related to deficiencies in the deserialization mechanism. Exploiting this vulnerability could allow a remote attacker to compromise the confidentiality, integrity, and accessibility of the protected...
IBM Tivoli Monitoring Buffer Overflow
The vulnerability of the IBM Tivoli Monitoring information infrastructure lies in the overflow of buffers in the dynamic memory. Exploiting this vulnerability could allow a malicious actor to execute arbitrary code or cause server failures...
IBM Tivoli Monitoring Buffer Overflow
The vulnerability of the IBM Tivoli Monitoring information infrastructure lies in the overflow of buffers in the dynamic memory. Exploiting this vulnerability could allow a malicious actor to execute arbitrary code or cause server failures...
Extending the OWASP Multi-Agentic System Threat Modeling Guide: Insights from Multi-Agent Security Research
We propose an extension to the OWASP Multi-Agentic System MAS Threat Modeling Guide, translating recent anticipatory research in multi-agent security MASEC into practical guidance for addressing challenges unique to large language model LLM-driven multi-agent architectures. Although OWASP's...
CVE-2025-40770
A vulnerability has been identified in SINEC Traffic Analyzer 6GK8822-1BG01-0BA0 All versions. The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks...
CVE-2025-40770
A vulnerability has been identified in SINEC Traffic Analyzer 6GK8822-1BG01-0BA0 All versions. The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks...
CVE-2025-40770
CVE-2025-40770 affects Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0, all versions). The vulnerability stems from a monitoring interface that is not operated in a strictly passive mode, allowing interaction with the interface and enabling man‑in‑the‑middle attacks. Impact is rated HIGH (conf...
Schneider Electric EcoStruxure Power Monitoring Expert
RISK EVALUATION Successful exploitation of these vulnerabilities could allow a remote attacker to read arbitrary files from the target machine, or to access internal services directly. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...
PT-2025-32665 · Siemens · Sinec Traffic Analyzer
Name of the Vulnerable Software and Affected Versions: SINEC Traffic Analyzer affected versions not specified Description: The application uses a monitoring interface that is not operating in a strictly passive mode, potentially allowing an attacker to interact with the interface and conduct...
PT-2025-32893 · Schneider Electric · Ecostruxure Power Monitoring Expert
Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: This issue is a directory traversal information disclosure vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert. The...
PT-2025-32891 · Schneider Electric · Ecostruxure Power Monitoring Expert
Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: This issue is a server-side request forgery SSRF information disclosure vulnerability within the GetPagesAsImages functionality of Schneider...
PT-2025-32894 · Schneider Electric · Ecostruxure Power Monitoring Expert
Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: This issue involves a directory traversal vulnerability within the HttpPostedFile functionality of Schneider Electric EcoStruxure Power...
CVE-2025-40770: Channel Accessible by Non-Endpoint
A vulnerability has been identified in SINEC Traffic Analyzer 6GK8822-1BG01-0BA0 All versions. The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks...
PT-2025-32890 · Schneider Electric · Ecostruxure Power Monitoring Expert
Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: The software contains a deserialization of untrusted data flaw within the GetFilteredSinkProvider component, potentially leading to remote cod...
Siemens SINEC Traffic Analyzer security vulnerabilities
Siemens SINEC Traffic Analyzer is a network traffic analysis tool from Siemens Germany. A security vulnerability exists in Siemens SINEC Traffic Analyzer, which stems from a non-strictly passive mode of the monitoring interface and could lead to a man-in-the-middle attack...
(0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetPagesAsImages Server-Side Request Forgery Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is not required to exploit this vulnerability. The specific flaw exists within the GetPagesAsImages method. The issue...
(0Day) Schneider Electric EcoStruxure Power Monitoring Expert HttpPostedFile Directory Traversal Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The specific flaw exists within the HttpPostedFile module. The issue results from the...