Lucene search
+L

10008 matches found

CVE
CVE
added 2025/12/22 11:7 a.m.17 views

CVE-2025-54890

Summary: Stored XSS in Centreon Infra Monitoring for the Hostgroup configuration page due to improper input neutralization. Affected software: Centreon Infra Monitoring. Vulnerable versions (per sources): 23.10.0–23.10.29, 24.04.0–24.04.19, 24.10.0–24.10.15. Impact (as stated): Stored XSS by user...

6.8CVSS5.6AI score0.0017EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2025/12/22 11:7 a.m.5 views

CVE-2025-54890 A user with elevated privileges can inject XSS in the Hostgroups configuration page

Improper Neutralization of Input During Web Page Generation XSS or 'Cross-site Scripting' vulnerability in Centreon Infra Monitoring Hostgroup configuration page allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.15, from 24.04.0...

6.8CVSS5.6AI score0.0017EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2025/12/22 10:59 a.m.37 views

CVE-2025-12514 A user with elevated privileges is able to introduce a SQL Injection using the Open-tickets Notification rules configuration parameters

Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Centreon Infra Monitoring - Open-tickets Notification rules configuration parameters, Open tickets modules allows SQL Injection to user with elevated privileges.This issue affects Infra Monitoring ...

7.2CVSS0.0028EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2025/12/22 10:59 a.m.6 views

CVE-2025-12514 A user with elevated privileges is able to introduce a SQL Injection using the Open-tickets Notification rules configuration parameters

Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Centreon Infra Monitoring - Open-tickets Notification rules configuration parameters, Open tickets modules allows SQL Injection to user with elevated privileges.This issue affects Infra Monitoring ...

7.2CVSS7.4AI score0.0028EPSS
SaveExploits0References2
OSV
OSV
added 2025/12/22 10:59 a.m.8 views

CVE-2025-12514 A user with elevated privileges is able to introduce a SQL Injection using the Open-tickets Notification rules configuration parameters

Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Centreon Infra Monitoring - Open-tickets Notification rules configuration parameters, Open tickets modules allows SQL Injection to user with elevated privileges.This issue affects Infra Monitoring ...

7.2CVSS7.7AI score
SaveExploits0References4
EUVD
EUVD
added 2025/12/22 10:59 a.m.10 views

EUVD-2025-204709

Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Centreon Infra Monitoring - Open-tickets Notification rules configuration parameters, Open tickets modules allows SQL Injection to user with elevated privileges.This issue affects Infra Monitoring ...

7.2CVSS7.3AI score0.0028EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2025/12/22 10:55 a.m.29 views

CVE-2025-8460 A user with elevated privileges can inject XSS in the Notification rules configuration page

Improper Neutralization of Input During Web Page Generation XSS or 'Cross-site Scripting' vulnerability in Centreon Infra Monitoring Notification rules, Open tickets module allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.5, from...

6.8CVSS0.0021EPSS
SaveExploits0References2
EUVD
EUVD
added 2025/12/22 10:55 a.m.25 views

EUVD-2025-204710

Improper Neutralization of Input During Web Page Generation XSS or 'Cross-site Scripting' vulnerability in Centreon Infra Monitoring Notification rules, Open tickets module allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.5, from...

6.8CVSS5.6AI score0.0021EPSS
SaveExploits0References2
CVE
CVE
added 2025/12/22 10:55 a.m.17 views

CVE-2025-8460

Centreon Infra Monitoring (Notification rules, Open tickets module) has a stored XSS vulnerability (CVE-2025-8460). Affected versions are 23.10.0–23.10.4, 24.04.0–24.04.5, and 24.10.0–24.10.5. Root cause: improper neutralization of user input in web page generation. Remediation per linked sources...

6.8CVSS5.7AI score0.0021EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2025/12/22 10:55 a.m.4 views

CVE-2025-8460 A user with elevated privileges can inject XSS in the Notification rules configuration page

Improper Neutralization of Input During Web Page Generation XSS or 'Cross-site Scripting' vulnerability in Centreon Infra Monitoring Notification rules, Open tickets module allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.5, from...

6.8CVSS5.7AI score0.0021EPSS
SaveExploits0References2
OSV
OSV
added 2025/12/22 10:55 a.m.12 views

CVE-2025-8460 A user with elevated privileges can inject XSS in the Notification rules configuration page

Improper Neutralization of Input During Web Page Generation XSS or 'Cross-site Scripting' vulnerability in Centreon Infra Monitoring Notification rules, Open tickets module allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.5, from...

6.8CVSS6AI score
SaveExploits0References4
CNNVD
CNNVD
added 2025/12/22 12:0 a.m.10 views

Centreon 安全漏洞

Centreon is a set of open source system monitoring tools from the French company Centreon . The product provides monitoring capabilities for network, system and application resources. A security vulnerability exists in Centreon version 24.10.0 up to and including version 24.10.5, version 24.04.0 ...

7.2CVSS7.6AI score0.0028EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2025/12/22 12:0 a.m.9 views

PT-2025-52644

Name of the Vulnerable Software and Affected Versions Centreon Infra Monitoring versions 23.10.0 through 23.10.29 Centreon Infra Monitoring versions 24.04.0 through 24.04.19 Centreon Infra Monitoring versions 24.10.0 through 24.10.15 Description The software contains an Improper Neutralization of...

6.8CVSS5.2AI score0.0017EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2025/12/22 12:0 a.m.8 views

PT-2025-52645

Name of the Vulnerable Software and Affected Versions Centreon Infra Monitoring versions 23.10.0 through 23.10.4 Centreon Infra Monitoring versions 24.04.0 through 24.04.5 Centreon Infra Monitoring versions 24.10.0 through 24.10.5 Description The software contains an Improper Neutralization of...

6.8CVSS5.8AI score0.0021EPSS
SaveExploits0References5
Packet Storm News
Packet Storm News
added 2025/12/22 12:0 a.m.9 views

Anti-Malicious ISAC: How to Jointly Monitor and Disrupt Your Foes?

Integrated sensing and communication ISAC systems are key enablers of future networks but raise significant security concerns. In this realm, the emergence of malicious ISAC systems has amplified the need for authorized parties to legitimately monitor suspicious communication links and protect...

6.9AI score
SaveExploits0
Positive Technologies
Positive Technologies
added 2025/12/22 12:0 a.m.13 views

PT-2025-52643

Name of the Vulnerable Software and Affected Versions Centreon Infra Monitoring - Open-tickets versions 23.10.0 through 23.10.4 Centreon Infra Monitoring - Open-tickets versions 24.04.0 through 24.04.5 Centreon Infra Monitoring - Open-tickets versions 24.10.0 through 24.10.5 Description A flaw...

7.2CVSS7.5AI score0.0028EPSS
SaveExploits0References6
HPE Security Bulletins
HPE Security Bulletins
added 2025/12/19 12:0 a.m.8 views

HPESBNW04989 rev.1 - HPE Unified OSS Console Assurance Monitoring (UOCAM), Multiple Vulnerabilities

Potential Security Impact: Local: URL Redirection; Remote: Creation and Deletion of Arbitrary Files, Multiple Vulnerabilities SUPPORTED SOFTWARE VERSIONS: ONLY impacted versions are listed. HPE Unified OSS Console UOC - Prior to UOCAM Version 3.1.19 CVSS Scores: | CVE | CVSS Vector | Base Score |...

7.5CVSS6.8AI score0.66535EPSS
SaveExploits4
ATTACKERKB
ATTACKERKB
added 2025/12/18 8:32 p.m.8 views

CVE-2025-62001

BullWall Ransomware Containment supports configurable file and directory exclusions such as '$RECYCLE.BIN' to balance monitoring scope and performance. Certain exclusion patterns could allow an authenticated attacker to rename directories in a way that avoids monitoring. Fixed in 4.6.1.14 and...

8.8CVSS5.5AI score0.00359EPSS
SaveExploits0References4Affected Software1
CNNVD
CNNVD
added 2025/12/18 12:0 a.m.8 views

Inductive Automation Ignition 安全漏洞

Inductive Automation Ignition is an integrated software platform for SCADA systems from Inductive Automation, USA. The platform supports SCADA Data Acquisition and Monitoring Systems, HMI Human Machine Interface and more. A security vulnerability exists in Inductive Automation Ignition that stems...

7.3CVSS6.5AI score0.00247EPSS
SaveExploits0References3
Malwarebytes
Malwarebytes
added 2025/12/16 11:10 a.m.13 views

Google is discontinuing its dark web report: why it matters

Google has announced that early next year they are discontinuing the dark web report, which was meant to monitor breach data that’s circulating on the dark web. The news raised some eyebrows, but Google says it’s ending the feature because feedback showed the reports didn’t provide “helpful next...

6.6AI score
SaveExploits0
Rows per page
Query Builder