Lucene search
+L

7231 matches found

IBM Security Bulletins
IBM Security Bulletins
added 2018/07/16 10:15 a.m.40 views

Security Bulletin: IBM InfoSphere Guardium Database Activity Monitor is affected by CVE-2014-0221, CVE-2014-0224, CVE-2014-0195, CVE-2014-0198, CVE-2010-5298, CVE-2014-3470

Summary Guardium appliance is RHEL 5.8 based and uses OpenSSL from Red Hat for communications between appliances. Vulnerability Details CVE-2014-0224 OpenSSL is vulnerable to a man-in-the-middle attack, caused by the use of weak keying material in SSL/TLS clients and servers. A remote attacker...

7.4CVSS1.4AI score0.99977EPSS
SaveExploits13Affected Software1
ATTACKERKB
ATTACKERKB
added 2018/07/11 6:29 p.m.5 views

Junos OS: Kernel crash (vmcore) during broadcast storm after enabling 'monitor traffic interface fxp0'

While experiencing a broadcast storm, placing the fxp0 interface into promiscuous mode via the 'monitor traffic interface fxp0' can cause the system to crash and restart vmcore. This issue only affects Junos OS 15.1 and later releases, and affects both single core and multi-core REs. Releases pri...

6.5CVSS5.5AI score0.0056EPSS
SaveExploits0References3Affected Software1
RedHat Linux
RedHat Linux
added 2018/07/11 6:21 p.m.17 views

ceph: ceph-mon does not perform authorization on OSD pool ops

A flaw was found in the way ceph mon handles user requests. Any authenticated ceph user having read access to ceph can delete and corrupt snapshot images...

8.1CVSS5.7AI score0.03249EPSS
SaveExploits0References4
RedHat Linux
RedHat Linux
added 2018/07/11 6:11 p.m.18 views

ceph: ceph-mon does not perform authorization on OSD pool ops

A flaw was found in the way ceph mon handles user requests. Any authenticated ceph user having read access to ceph can delete and corrupt snapshot images...

8.1CVSS5.7AI score0.03249EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2018/07/11 6:0 p.m.24 views

CVE-2018-0029 Junos OS: Kernel crash (vmcore) during broadcast storm after enabling 'monitor traffic interface fxp0'

While experiencing a broadcast storm, placing the fxp0 interface into promiscuous mode via the 'monitor traffic interface fxp0' can cause the system to crash and restart vmcore. This issue only affects Junos OS 15.1 and later releases, and affects both single core and multi-core REs. Releases pri...

5.7CVSS6.5AI score0.0056EPSS
SaveExploits0References2
OSV
OSV
added 2018/07/10 2:29 p.m.2 views

DEBIAN-CVE-2018-10861

A flaw was found in the way ceph mon handles user requests. Any authenticated ceph user having read access to ceph can delete, create ceph storage pools and corrupt snapshot images. Ceph branches master, mimic, luminous and jewel are believed to be affected...

8.1CVSS6.3AI score0.03249EPSS
SaveExploits0References1
OSV
OSV
added 2018/07/10 2:29 p.m.4 views

UBUNTU-CVE-2018-10861

A flaw was found in the way ceph mon handles user requests. Any authenticated ceph user having read access to ceph can delete, create ceph storage pools and corrupt snapshot images. Ceph branches master, mimic, luminous and jewel are believed to be affected...

8.1CVSS6.8AI score0.03249EPSS
SaveExploits0References2
IBM Security Bulletins
IBM Security Bulletins
added 2018/07/06 12:22 a.m.35 views

Security Bulletin: A security vulnerability has been identified in IBM WebSphere Application Server shipped with IBM Business Monitor (CVE-2012-5783)

Summary IBM WebSphere Application Server is shipped as components of Business Monitor. Information about a security vulnerability affecting WebSphere Application Server has been published in a security bulletin. Vulnerability Details Consult the Security Bulletin Information disclosure in Apache...

5.8CVSS1.3AI score0.09254EPSS
SaveExploits0Affected Software1
IBM Security Bulletins
IBM Security Bulletins
added 2018/07/06 12:17 a.m.23 views

Security Bulletin: A security vulnerability has been identified in IBM WebSphere Application Server shipped with IBM Business Monitor (CVE-2018-1614)

Summary IBM WebSphere Application Server is shipped as components of Business Monitor. Information about a security vulnerability affecting WebSphere Application Server has been published in a security bulletin. Vulnerability Details Consult the Security Bulletin Security Bulletin: Information...

7.5CVSS2.3AI score0.02902EPSS
SaveExploits0Affected Software1
IBM Security Bulletins
IBM Security Bulletins
added 2018/07/06 12:11 a.m.22 views

Security Bulletin: A security vulnerability has been identified in IBM WebSphere Application Server shipped with IBM Business Monitor (CVE-2018-1621)

Summary IBM WebSphere Application Server is shipped as a component of Business Monitor. Information about a security vulnerability affecting WebSphere Application Server has been published in a security bulletin. Vulnerability Details Consult the Security Bulletin Information Disclosure in...

6.7CVSS2.4AI score0.00265EPSS
SaveExploits0Affected Software1
CNVD
CNVD
added 2018/07/04 12:0 a.m.5 views

Motorola MBP853 Certificate Validation Vulnerability

The Motorola MBP853 is a baby monitoring device from Motorola USA. A security vulnerability exists in the firmware of the Motorola MBP853, which stems from the program failing to properly validate the server certificate. An attacker could use this vulnerability to conduct a man-in-the-middle atta...

7.4CVSS6.8AI score0.00482EPSS
SaveExploits0References1
NVD
NVD
added 2018/07/03 1:29 a.m.19 views

CVE-2018-8868

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit oth...

6.9CVSS6.6AI score0.00333EPSS
SaveExploits0References2
NVD
NVD
added 2018/07/03 1:29 a.m.30 views

CVE-2018-8870

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...

7.2CVSS6.6AI score0.00362EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2018/07/03 1:29 a.m.4 views

CVE-2018-8870

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...

7.2CVSS5.5AI score0.00362EPSS
SaveExploits0References3
Prion
Prion
added 2018/07/03 1:29 a.m.21 views

Input validation

Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An...

6.9CVSS6.6AI score0.00333EPSS
SaveExploits0References1
Prion
Prion
added 2018/07/03 1:29 a.m.16 views

Hardcoded credentials

Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain...

7.2CVSS6.7AI score0.00362EPSS
SaveExploits0References1
CVE
CVE
added 2018/07/02 6:0 p.m.61 views

CVE-2018-8868

Medtronic MyCareLink Monitor devices (24950 and 24952) contain debug code that enables reading/writing arbitrary memory on implantable devices via short-range wireless interfaces. The vulnerability CVE-2018-8868 arises from an exposed dangerous function debugging path, allowing near-physically pr...

6.9CVSS6.6AI score0.00333EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2018/07/02 6:0 p.m.29 views

CVE-2018-8868 Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit oth...

6.2CVSS6.6AI score0.00333EPSS
SaveExploits0References2
CVE
CVE
added 2018/07/02 6:0 p.m.57 views

CVE-2018-8870

CVE-2018-8870 affects Medtronic MyCareLink Monitors (models 24950 and 24952). The vulnerability is a hard-coded operating system password, enabling a physically proximate attacker who can open the device and connect via a debug port to gain privileged OS access. The ICS-CERT advisory corroborates...

7.2CVSS6.5AI score0.00362EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2018/07/02 6:0 p.m.21 views

CVE-2018-8870 Medtronic MyCareLink Patient Monitor Use of Hard-coded Password

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...

6.4CVSS6.7AI score0.00362EPSS
SaveExploits0References2
Rows per page
Query Builder