Lucene search
+L

9660 matches found

Patchstack
Patchstack
•added 2025/02/03 4:12 p.m.•14 views

WordPress WP Keyword Monitor Plugin <=1.0.5 - CSRF to Stored XSS vulnerability

CSRF to Stored XSS vulnerability discovered by 0xd4rk5id3 in WordPress Plugin WP Keyword Monitor versions = 1.0.5...

7.1CVSS6.2AI score0.00155EPSS
SaveExploits0Affected Software1
osv_mal
osv_mal
•added 2025/02/03 9:01 a.m.•10 views

MAL-2025-1109 Malicious code in deribit-arbitrage-monitor (npm)

--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware 64bc92786b02e2d413eda2df2dae650fcd3c651e901b32f32ba4fb5c27bbd258 Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...

7AI score
SaveExploits0References3
OSSF Malicious Packages
OSSF Malicious Packages
•added 2025/02/03 9:01 a.m.•10 views

Malicious code in deribit-arbitrage-monitor (npm)

--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware 64bc92786b02e2d413eda2df2dae650fcd3c651e901b32f32ba4fb5c27bbd258 Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...

6.9AI score
SaveExploits0References3
BDU FSTEC
BDU FSTEC
•added 2025/02/03 12:00 a.m.•11 views

Linux kernel drop_monitor DoS

The vulnerability of the dropmonitor component in the Linux operating system’s kernel is related to improper locking mechanisms. Exploiting this vulnerability can allow an attacker to cause a service failure...

5.5CVSS6.4AI score0.00757EPSS
SaveExploits0References44Affected Software9
BDU FSTEC
BDU FSTEC
•added 2025/02/03 12:00 a.m.•17 views

batman-adv DoS

The vulnerability of the dropmonitor component in the Linux operating system’s kernel is related to improper locking mechanisms. Exploiting this vulnerability can allow an attacker to cause a service failure...

5.5CVSS6.5AI score0.00231EPSS
SaveExploits0References45Affected Software8
vulnersOsv
vulnersOsv
•added 2025/01/31 5:34 p.m.•2 views

org.hawkular.agent:hawkular-dmr-client (>=0.1.0, <=0.3.0), org.hawkular.agent:hawkular-monitor (>=0.1.0, <=0.3.0) +38 more potentially affected by CVE-2025-23367 via org.wildfly.core:wildfly-server (1.0.0.cr6)

org.wildfly.core:wildfly-server MAVEN version 1.0.0.cr6 is affected by a known vulnerability. The following packages have a transitive dependency on org.wildfly.core:wildfly-server and may be impacted: - org.hawkular.agent:hawkular-dmr-client =0.1.0, =0.1.0, =0.1.0, =0.1.0, =1.3.0.final,...

6.5CVSS0.00774EPSS
SaveExploits0
vulnersOsv
vulnersOsv
•added 2025/01/31 5:34 p.m.•2 views

com.bertoncelj.wildflysingletonservice:wildfly-singleton-service (1.0.1), org.hawkular.agent:hawkular-dmr-client (>=0.6.0.final, <=0.14.0.final) +50 more potentially affected by CVE-2025-23367 via org.wildfly.core:wildfly-server (1.0.1.final)

org.wildfly.core:wildfly-server MAVEN version 1.0.1.final is affected by a known vulnerability. The following packages have a transitive dependency on org.wildfly.core:wildfly-server and may be impacted: - com.bertoncelj.wildflysingletonservice:wildfly-singleton-service 1.0.1 -...

6.5CVSS0.00774EPSS
SaveExploits0
Positive Technologies
Positive Technologies
•added 2025/01/31 12:00 a.m.•1 views

PT-2025-14290

Name of the Vulnerable Software and Affected Versions Linux kernel affected versions not specified Description A vulnerability in the Linux kernel has been resolved, related to the wifi and nl80211 components. The issue arises when both MONITOR FLAG COOK FRAMES and MONITOR FLAG ACTIVE flags are s...

5.5CVSS0.00167EPSS
SaveExploits0
CVE
CVE
•added 2025/01/30 6:17 p.m.•90 views

CVE-2025-0683

The CVE-2025-0683 entry affects Contec Health CMS8000 Patient Monitor. In its default configuration, it transmits plain-text patient data to a hard-coded public IP address, enabling potential data leakage to any device on that IP and enabling MITM-like interception. Public advisories (CISA ICS wa...

8.2CVSS6AI score0.00792EPSS
SaveIn wildExploits0References4
Vulnrichment
Vulnrichment
•added 2025/01/30 6:17 p.m.•9 views

CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS7.7AI score0.01149EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2025/01/30 6:17 p.m.•54 views

CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS0.01149EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2025/01/30 6:17 p.m.•61 views

CVE-2024-12248 Out-of-bounds Write vulnerability in Contec Health CMS8000 Patient Monitor

Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution...

9.8CVSS0.01299EPSS
SaveExploits0References2
CVE
CVE
•added 2025/01/30 6:17 p.m.•109 views

CVE-2024-12248

The CVE-2024-12248 issue affects Contec Health CMS8000 Patient Monitor. It is an out-of-bounds write vulnerability allowing an attacker to craft UDP requests to write arbitrary data, potentially enabling remote code execution. Connected documents confirm the affected product family (CMS8000 CMS a...

9.8CVSS9.8AI score0.01299EPSS
SaveIn wildExploits0References2
Snyk
Snyk
•added 2025/01/30 3:31 p.m.•10 views

Missing Authorization

Overview Affected versions of this package are vulnerable to Missing Authorization in the execute functions in ServerSuspendHandler.java and ServerResumeHandler.java, which do not perform sufficient checks for the authorization of the running user. This allows a user with the Monitor or Auditor...

7.1CVSS6.9AI score0.00774EPSS
SaveExploits0References2
attackerkb
attackerkb
•added 2025/01/30 3:15 p.m.•15 views

CVE-2025-23367

A flaw was found in the Wildfly Server Role Based Access Control RBAC provider. When authorization to control management operations is secured using the Role Based Access Control provider, a user without the required privileges can suspend or resume the server. A user with a Monitor or Auditor ro...

6.5CVSS5.4AI score0.00774EPSS
SaveExploits0References13Affected Software14
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/30 12:00 a.m.•9 views

CVE-2025-0683: Exposure of Private Personal Information to an Unauthorized Actor

In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text patient data to a hard-coded public IP address when a patient is hooked up to the monitor. This could lead to a leakage of confidential patient data to any device with that IP address or an attacker in a...

8.2CVSS8.1AI score0.00792EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/30 12:00 a.m.•4 views

CVE-2025-0626: Hidden Functionality

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS8.2AI score0.01149EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/01/30 12:00 a.m.•19 views

Contec Health CMS8000 Patient Monitor has a security vulnerability

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker could exploit the vulnerability to upload and overwrite files on the device...

7.7CVSS9.4AI score0.01149EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2025/01/30 12:00 a.m.•20 views

Contec Health CMS8000 Patient Monitor has a security vulnerability

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor that originates from allowing the transmission of plain text patient data to a hard-coded public IP address...

8.2CVSS9.4AI score0.00792EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2025/01/30 12:00 a.m.•15 views

Contec Health CMS8000 Patient Monitor has a security vulnerability

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker can exploit the vulnerability to send specially formatted UDP requests to write arbitrary data...

9.8CVSS9.5AI score0.01299EPSS
SaveExploits0References2
Rows per page
Query Builder