8984 matches found
Linux kernel drop_monitor DoS
The vulnerability of the dropmonitor component in the Linux operating system’s kernel is related to improper locking mechanisms. Exploiting this vulnerability can allow an attacker to cause a service failure...
org.hawkular.agent:hawkular-dmr-client (>=0.1.0, <=0.3.0), org.hawkular.agent:hawkular-monitor (>=0.1.0, <=0.3.0) +38 more potentially affected by CVE-2025-23367 via org.wildfly.core:wildfly-server (1.0.0.cr6)
org.wildfly.core:wildfly-server MAVEN version 1.0.0.cr6 is affected by a known vulnerability. The following packages have a transitive dependency on org.wildfly.core:wildfly-server and may be impacted: - org.hawkular.agent:hawkular-dmr-client =0.1.0, =0.1.0, =0.1.0, =0.1.0, =1.3.0.final,...
PT-2025-14290
Name of the Vulnerable Software and Affected Versions Linux kernel affected versions not specified Description A vulnerability in the Linux kernel has been resolved, related to the wifi and nl80211 components. The issue arises when both MONITOR FLAG COOK FRAMES and MONITOR FLAG ACTIVE flags are s...
CVE-2025-0683
The CVE-2025-0683 entry affects Contec Health CMS8000 Patient Monitor. In its default configuration, it transmits plain-text patient data to a hard-coded public IP address, enabling potential data leakage to any device on that IP and enabling MITM-like interception. Public advisories (CISA ICS wa...
CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor
The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...
CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor
The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...
CVE-2024-12248 Out-of-bounds Write vulnerability in Contec Health CMS8000 Patient Monitor
Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution...
CVE-2024-12248
The CVE-2024-12248 issue affects Contec Health CMS8000 Patient Monitor. It is an out-of-bounds write vulnerability allowing an attacker to craft UDP requests to write arbitrary data, potentially enabling remote code execution. Connected documents confirm the affected product family (CMS8000 CMS a...
Missing Authorization
Overview Affected versions of this package are vulnerable to Missing Authorization in the execute functions in ServerSuspendHandler.java and ServerResumeHandler.java, which do not perform sufficient checks for the authorization of the running user. This allows a user with the Monitor or Auditor...
CVE-2025-23367
A flaw was found in the Wildfly Server Role Based Access Control RBAC provider. When authorization to control management operations is secured using the Role Based Access Control provider, a user without the required privileges can suspend or resume the server. A user with a Monitor or Auditor ro...
CVE-2025-0626: Hidden Functionality
The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...
CVE-2024-12248: Out-of-bounds Write
Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution...
Contec Health CMS8000 Patient Monitor 安全漏洞
Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker can exploit the vulnerability to send specially formatted UDP requests to write arbitrary data...
CVE-2025-0683: Exposure of Private Personal Information to an Unauthorized Actor
In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text patient data to a hard-coded public IP address when a patient is hooked up to the monitor. This could lead to a leakage of confidential patient data to any device with that IP address or an attacker in a...
Contec Health CMS8000 Patient Monitor 安全漏洞
Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker could exploit the vulnerability to upload and overwrite files on the device...
Contec Health CMS8000 Patient Monitor 安全漏洞
Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor that originates from allowing the transmission of plain text patient data to a hard-coded public IP address...
wifi: cfg80211: clear wdev->cqm_config pointer on free
...
RuoYi 安全漏洞
RuoYi is a backend management system for individual developers of RuoYi in China. A security vulnerability exists in RuoYi version v4.8.0, which originates from allowing an unauthorized attacker to view an administrator's session ID in System Monitor...
CVE-2024-57437: Improper Neutralization of Special Elements used in an SQL Command
RuoYi v4.8.0 was discovered to contain a SQL injection vulnerability via the orderby parameter at /monitor/online/list...