Lucene search
+L

7436 matches found

OSSF Malicious Packages
OSSF Malicious Packages
added 2025/02/03 9:01 a.m.7 views

Malicious code in deribit-arbitrage-monitor (npm)

--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware 64bc92786b02e2d413eda2df2dae650fcd3c651e901b32f32ba4fb5c27bbd258 Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...

6.9AI score
SaveExploits0References3
OSV
OSV
added 2025/02/03 9:01 a.m.5 views

MAL-2025-1109 Malicious code in deribit-arbitrage-monitor (npm)

--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware 64bc92786b02e2d413eda2df2dae650fcd3c651e901b32f32ba4fb5c27bbd258 Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...

7AI score
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2025/02/03 12:00 a.m.7 views

The vulnerability of the drop_monitor component in the Linux operating system’s kernel allows a hacker to trigger a service failure.

The vulnerability of the dropmonitor component in the Linux operating system’s kernel is related to improper locking mechanisms. Exploiting this vulnerability can allow an attacker to cause a service failure...

5.5CVSS6.4AI score0.00757EPSS
SaveExploits0References44Affected Software9
BDU FSTEC
BDU FSTEC
added 2025/02/03 12:00 a.m.11 views

The vulnerability of the batman-adv component in the Linux operating system, which allows a hacker to cause a service failure.

The vulnerability of the dropmonitor component in the Linux operating system’s kernel is related to improper locking mechanisms. Exploiting this vulnerability can allow an attacker to cause a service failure...

5.5CVSS6.5AI score0.00231EPSS
SaveExploits0References45Affected Software8
CVE
CVE
added 2025/01/30 6:17 p.m.77 views

CVE-2025-0683

The CVE-2025-0683 entry affects Contec Health CMS8000 Patient Monitor. In its default configuration, it transmits plain-text patient data to a hard-coded public IP address, enabling potential data leakage to any device on that IP and enabling MITM-like interception. Public advisories (CISA ICS wa...

8.2CVSS6AI score0.00792EPSS
SaveIn wildExploits0References4
Cvelist
Cvelist
added 2025/01/30 6:17 p.m.38 views

CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS0.01158EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2025/01/30 6:17 p.m.9 views

CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS7.7AI score0.01158EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2025/01/30 6:17 p.m.51 views

CVE-2024-12248 Out-of-bounds Write vulnerability in Contec Health CMS8000 Patient Monitor

Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution...

9.8CVSS0.01299EPSS
SaveExploits0References2
CVE
CVE
added 2025/01/30 6:17 p.m.92 views

CVE-2024-12248

The CVE-2024-12248 issue affects Contec Health CMS8000 Patient Monitor. It is an out-of-bounds write vulnerability allowing an attacker to craft UDP requests to write arbitrary data, potentially enabling remote code execution. Connected documents confirm the affected product family (CMS8000 CMS a...

9.8CVSS9.8AI score0.01299EPSS
SaveIn wildExploits0References2
Snyk
Snyk
added 2025/01/30 3:31 p.m.6 views

Missing Authorization

Overview Affected versions of this package are vulnerable to Missing Authorization in the execute functions in ServerSuspendHandler.java and ServerResumeHandler.java, which do not perform sufficient checks for the authorization of the running user. This allows a user with the Monitor or Auditor...

7.1CVSS6.9AI score0.00678EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2025/01/30 3:15 p.m.6 views

CVE-2025-23367

A flaw was found in the Wildfly Server Role Based Access Control RBAC provider. When authorization to control management operations is secured using the Role Based Access Control provider, a user without the required privileges can suspend or resume the server. A user with a Monitor or Auditor ro...

6.5CVSS5.4AI score0.00678EPSS
SaveExploits0References13Affected Software14
CNNVD
CNNVD
added 2025/01/30 12:00 a.m.14 views

Contec Health CMS8000 Patient Monitor 安全漏洞

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor that originates from allowing the transmission of plain text patient data to a hard-coded public IP address...

8.2CVSS9.4AI score0.00792EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2025/01/30 12:00 a.m.6 views

Contec Health CMS8000 Patient Monitor 安全漏洞

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker can exploit the vulnerability to send specially formatted UDP requests to write arbitrary data...

9.8CVSS9.5AI score0.01299EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2025/01/30 12:00 a.m.8 views

Contec Health CMS8000 Patient Monitor 安全漏洞

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker could exploit the vulnerability to upload and overwrite files on the device...

7.7CVSS9.4AI score0.01158EPSS
SaveExploits0References5
Microsoft CVE
Microsoft CVE
added 2025/01/29 8:00 a.m.7 views

wifi: cfg80211: clear wdev->cqm_config pointer on free

...

7.8CVSS7.3AI score0.00244EPSS
SaveExploits0
CNNVD
CNNVD
added 2025/01/29 12:00 a.m.9 views

RuoYi 安全漏洞

RuoYi is a backend management system by the individual developer RuoYi in China. A security vulnerability exists in RuoYi v4.8.0, which is caused by an SQL injection via the orderby parameter in /monitor/online/list...

6.5CVSS7.7AI score0.00493EPSS
SaveExploits1References4
CNNVD
CNNVD
added 2025/01/29 12:00 a.m.13 views

RuoYi 安全漏洞

RuoYi is a backend management system for individual developers of RuoYi in China. A security vulnerability exists in RuoYi version v4.8.0, which originates from allowing an unauthorized attacker to view an administrator's session ID in System Monitor...

7.2CVSS6.4AI score0.00644EPSS
SaveExploits1References3
OSV
OSV
added 2025/01/29 12:00 a.m.10 views

CVE-2024-57437

RuoYi v4.8.0 was discovered to contain a SQL injection vulnerability via the orderby parameter at /monitor/online/list...

6.5CVSS8.2AI score
SaveExploits0References6
IBM Security Bulletins
IBM Security Bulletins
added 2025/01/28 10:08 p.m.33 views

Security Bulletin: IBM Maximo Application Suite - Monitor Component is vulnerable to requests-2.31.0-py3-none-any.whl CVE-2024-35195

Summary IBM Maximo Application Suite - Monitor Component is vulnerable to requests-2.31.0-py3-none-any.whl CVE-2024-35195. This bulletin identifies the steps to take to address the vulnerabilities. Vulnerability Details CVEID:CVE-2024-35195 DESCRIPTION: Psf Requests could allow a local...

5.6CVSS6.2AI score0.0034EPSS
SaveExploits0Affected Software1
IBM Security Bulletins
IBM Security Bulletins
added 2025/01/28 10:08 p.m.11 views

Security Bulletin: IBM Maximo Application Suite - Monitor Component is vulnerable to ipp-3.15.0-py3-none-any.whl CVE-2024-5569

Summary IBM Maximo Application Suite - Monitor Component is vulnerable to ipp-3.15.0-py3-none-any.whl CVE-2024-5569. This bulletin identifies the steps to take to address the vulnerabilities. Vulnerability Details CVEID:CVE-2024-5569 DESCRIPTION: zipp is vulnerable to a denial of service, caused ...

6.2CVSS6.2AI score0.00236EPSS
SaveExploits0Affected Software1
Rows per page
Query Builder