7353 matches found
CVE-2025-40830
A vulnerability has been identified in SINEC Security Monitor All versions V4.10.0. The affected application does not have proper authorization checks for the filetransfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any...
DEBIAN-CVE-2023-53828
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hcisync: Avoid use-after-free in dbg for hciaddadvmonitor KSAN reports use-after-free in hciaddadvmonitor. While adding an adv monitor, hciaddadvmonitor calls - msftaddmonitorpattern calls - msftaddmonitorsync calls -...
CVE-2023-53828
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hcisync: Avoid use-after-free in dbg for hciaddadvmonitor KSAN reports use-after-free in hciaddadvmonitor. While adding an adv monitor, hciaddadvmonitor calls - msftaddmonitorpattern calls - msftaddmonitorsync calls -...
UBUNTU-CVE-2023-53828
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hcisync: Avoid use-after-free in dbg for hciaddadvmonitor KSAN reports use-after-free in hciaddadvmonitor. While adding an adv monitor, hciaddadvmonitor calls - msftaddmonitorpattern calls - msftaddmonitorsync calls -...
Security Bulletin: IBM Maximo Application Suite - Monitor Component uses form-data-4.0.0.tgz, form-data-4.0.1.tgz, form-data-4.0.3.tgz which are vulnerable to CVE-2025-7783.
Summary IBM Maximo Application Suite - Monitor Component uses form-data-4.0.0.tgz, form-data-4.0.1.tgz, form-data-4.0.3.tgz which are vulnerable to CVE-2025-7783. This bulletin contains information addressing the vulnerability. Vulnerability Details CVEID:CVE-2025-7783 DESCRIPTION: Use of...
CVE-2025-40831
A vulnerability has been identified in SINEC Security Monitor All versions V4.10.0. The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report...
CVE-2025-40831
A vulnerability has been identified in SINEC Security Monitor All versions V4.10.0. The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report...
CVE-2025-40831
SINEC Security Monitor prior to V4.10.0 is affected by an input validation flaw in the date parameter of the report generation function. This could allow an authenticated, low-priv attacker to cause a denial-of-service condition in the report feature. Mitigation: upgrade to V4.10.0 or later (per ...
CVE-2025-40830
A vulnerability has been identified in SINEC Security Monitor All versions V4.10.0. The affected application does not have proper authorization checks for the filetransfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any...
CVE-2025-40830
A vulnerability has been identified in SINEC Security Monitor All versions V4.10.0. The affected application does not have proper authorization checks for the filetransfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any...
CVE-2025-40830
CVE-2025-40830 affects Siemens SINEC Security Monitor before version 4.10.0. The issue is missing authorization checks for the file_transfer feature in ssmctl-client, enabling an authenticated, low-priv local attacker to read or write arbitrary files on the server or sensor. Mitigation: upgrade t...
Windows Camera Frame Server Monitor Information Disclosure Vulnerability
Improper access control in Windows Camera Frame Server Monitor allows an authorized attacker to disclose information locally...
Azure Monitor Agent Remote Code Execution Vulnerability
Out-of-bounds write in Azure Monitor Agent allows an authorized attacker to execute code over a network...
CVE-2023-53828
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hcisync: Avoid use-after-free in dbg for hciaddadvmonitor KSAN reports use-after-free in hciaddadvmonitor. While adding an adv monitor, hciaddadvmonitor calls - msftaddmonitorpattern calls - msftaddmonitorsync calls -...
CVE-2023-53828
CVE-2023-53828 affects the Linux kernel Bluetooth subsystem (net/bluetooth/hci_core.c) where hci_add_adv_monitor() triggers a use-after-free via a path through msft_add_monitor_pattern(), msft_add_monitor_sync(), and msft_le_monitor_advertisement_cb() in error handling. KSAN reported the use-afte...
CVE-2023-53828 Bluetooth: hci_sync: Avoid use-after-free in dbg for hci_add_adv_monitor()
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hcisync: Avoid use-after-free in dbg for hciaddadvmonitor KSAN reports use-after-free in hciaddadvmonitor. While adding an adv monitor, hciaddadvmonitor calls - msftaddmonitorpattern calls - msftaddmonitorsync calls -...
CVE-2023-53828 Bluetooth: hci_sync: Avoid use-after-free in dbg for hci_add_adv_monitor()
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hcisync: Avoid use-after-free in dbg for hciaddadvmonitor KSAN reports use-after-free in hciaddadvmonitor. While adding an adv monitor, hciaddadvmonitor calls - msftaddmonitorpattern calls - msftaddmonitorsync calls -...
SUSE CVE-2022-50627
In the Linux kernel, the following vulnerability has been resolved: wifi: ath11k: fix monitor mode bringup crash When the interface is brought up in monitor mode, it leads to NULL pointer dereference crash. This crash happens when the packet type is extracted for a SKB. This extraction which is...
SUSE CVE-2025-40294
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: MGMT: Fix OOB access in parseadvmonitorpattern In the parseadvmonitorpattern function, the value of the 'length' variable is currently limited to HCIMAXEXTADLENGTH251. The size of the 'value' array in the mgmtadvpatter...
Siemens SINEC Security Monitor 输入验证错误漏洞
Siemens SINEC Security Monitor is an industrial security monitor from Siemens Germany. An input validation error vulnerability exists in Siemens SINEC Security Monitor versions prior to V4.10.0, which stems from a lack of input validation for the date parameter in the report generation function,...