Lucene search
+L

1693 matches found

Prion
Prion
added 2014/10/03 6:55 p.m.23 views

Directory traversal

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103...

10CVSS7.2AI score0.08978EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2014/10/03 6:0 p.m.51 views

CVE-2014-0754 Schneider Electric

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103...

10CVSS6.7AI score0.08978EPSS
SaveExploits0References3
CVE
CVE
added 2014/10/03 6:0 p.m.106 views

CVE-2014-0754

CVE-2014-0754 is a directory traversal vulnerability in Schneider Electric Modicon PLC Ethernet modules (SchneiderWEB). Affected Exec firmware/versions include 140CPU65x before 5.5, 140NOC78x before 1.62, 140NOE77x before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x before 6.0,...

10CVSS6.9AI score0.08978EPSS
SaveExploits0References5Affected Software1
Positive Technologies
Positive Technologies
added 2014/10/03 12:0 a.m.12 views

PT-2014-3817 · Schneider Electric · Modicon Plc Ethernet Modules +1

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec versions prior to 5.5 Schneider Electric Modicon PLC Ethernet modules 140NOC78x Exec versions prior to 1.62 Schneider Electric Modicon PLC Ethernet modules 140NOE77x Exec versions...

10CVSS7.3AI score0.08978EPSS
SaveExploits0References8
Tenable Nessus
Tenable Nessus
added 2014/03/25 12:0 a.m.46 views

Default FTP Credentials (ntpupdate / ntpupdate)

It is possible to log into the remote FTP server by providing default credentials. A remote attacker could exploit this to gain access to the remote server. These credentials are known to apply to Schneider Electric Modicon M340 for Ethernet devices; however, they may apply to other FTP services ...

5.5AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2014/02/26 12:0 a.m.19 views

Modicon Modbus/TCP Programming Function Code Access (SCADA) (deprecated)

Binary data 3852.prm...

7.3AI score
SaveExploits0References1
ICS
ICS
added 2013/12/20 7:0 a.m.36 views

Schneider Electric PLCs Vulnerabilities

OVERVIEW --------- Begin Update B Part 1 of 2 -------- This updated advisory is a follow-up to the previous advisory update titled ICSA-13-077-01A Schneider Electric PLCs Vulnerabilities Update A that was published March 20, 2013, on the ICS-CERT Web page. It is also a follow-up to the updated...

7.4AI score
SaveExploits0References10
OpenVAS
OpenVAS
added 2013/12/16 12:0 a.m.13 views

Schneider Electric Modicon M340 Detection (HTTP)

HTTP based detection of Schneider Electric Modicon M340 devices. SPDX-FileCopyrightText: 2013 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...

7.4AI score
SaveExploits0References1
OpenVAS
OpenVAS
added 2013/12/16 12:0 a.m.18 views

Schneider Modicon M340 Device Default Credentials (HTTP)

The remote Schneider Modicon M340 device is using known default credentials. SPDX-FileCopyrightText: 2013 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only CPE =...

7.5AI score
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2013/05/15 12:0 a.m.9 views

PT-2013-1323 · Schneider Electric · Modicon M340 +2

Name of the Vulnerable Software and Affected Versions: Modicon M340 versions affected versions not specified Modicon Quantum versions affected versions not specified Modicon Premium versions affected versions not specified Description: The issue is related to errors in security mechanisms, which...

5.3CVSS6.8AI score0.00898EPSS
SaveExploits0References23
Check Point Advisories
Check Point Advisories
added 2012/12/27 12:0 a.m.7 views

Schneider Modicon SCADA Ladder Logic Upload/Download

A vulnerability has been reported in Schneider Electric Modicon Quantum. The vulnerability is due to the use of unauthenticated administrative function...

7.1AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2012/12/27 12:0 a.m.6 views

Schneider Modicon SCADA Remote START/STOP Command

A vulnerability has been reported in Schneider Electric Modicon Quantum. The vulnerability is due to the use of unauthenticated administrative function...

7.1AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2012/12/26 12:0 a.m.3 views

SCADA Schneider Modicon Quantum Password Recovery

...

7AI score
SaveExploits0
Metasploit
Metasploit
added 2012/04/05 12:0 a.m.46 views

Schneider Modicon Ladder Logic Upload/Download

The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to send and receive ladder logic. The protocol is unauthenticated, and allows a rogue host to retrieve the existing logic and to upload new logic. Two modes are supported: "SEND" and "RECV," which behave as one might...

5.5AI score
SaveExploits0
Metasploit
Metasploit
added 2012/04/05 12:0 a.m.51 views

Schneider Modicon Remote START/STOP Command

The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to perform administrative commands without authentication. This module allows a remote user to change the state of the PLC between STOP and RUN, allowing an attacker to end process control by the PLC. This module is...

5.5AI score
SaveExploits0
NVD
NVD
added 2012/01/28 1:55 a.m.13 views

CVE-2012-0929

Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the 1 FTP server or 2 HTTP server...

7.8CVSS7.6AI score0.04928EPSS
SaveExploits0References6
NVD
NVD
added 2012/01/28 1:55 a.m.18 views

CVE-2012-0930

Cross-site scripting XSS vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...

6.1CVSS6AI score0.02242EPSS
SaveExploits0References5
NVD
NVD
added 2012/01/28 1:55 a.m.19 views

CVE-2012-0931

Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors...

9.8CVSS10AI score0.04922EPSS
SaveExploits0References5
Prion
Prion
added 2012/01/28 1:55 a.m.21 views

Cross site scripting

Cross-site scripting XSS vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...

4.3CVSS6.1AI score0.02242EPSS
SaveExploits0References5
Prion
Prion
added 2012/01/28 1:55 a.m.17 views

Authentication flaw

Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors...

7.5CVSS8.9AI score0.04922EPSS
SaveExploits0References5
Rows per page
Query Builder