CVE-2018-7831
This entry documents CVE-2018-7831, affecting Schneider Electric Modicon embedded web servers in M340, Premium, Quantum PLCs and BMXNOR0200. The vulnerability is an improper neutralization of script-related HTML tags (Basic XSS) that can be exploited by sending a specially crafted URL to a curren...
CVE-2018-7831
An Improper Neutralization of Script-Related HTML Tags in a Web Page Basic XSS vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a...
CVE-2018-7809
The CVE-2018-7809 issue affects Schneider Electric Modicon embedded Web servers in M340, Premium, Quantum PLCs and BMXNOR0200. The root cause is an Unverified Password Change vulnerability that allows an unauthenticated remote attacker to access the password delete function via the web server. Im...
CVE-2018-7809
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete function of the web server...
CVE-2018-7810
An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browse...
CVE-2018-7810
CVE-2018-7810 is an XSS vulnerability in the embedded web servers of Schneider Electric Modicon M340, Premium, Quantum PLCs and BMXNOR0200. The root cause is improper neutralization of input during web page generation, allowing an attacker to craft a URL containing JavaScript that will be execute...
CVE-2018-7830: Improper Neutralization of CRLF Sequences in HTTP Headers
Improper Neutralization of CRLF Sequences in HTTP Headers 'HTTP Response Splitting' vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a denial of service can occur for 1 minute by sending a specially crafted HTTP request...
CVE-2018-7810: Improper Neutralization of Input During Web Page Generation
An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browse...
CVE-2018-7831: Improper Neutralization of Input During Web Page Generation
An Improper Neutralization of Script-Related HTML Tags in a Web Page Basic XSS vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a...
CVE-2018-7811: Weak Password Recovery Mechanism for Forgotten Password
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password function of the web server...
CVE-2018-7809: Weak Password Recovery Mechanism for Forgotten Password
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete function of the web server...
Denial of Service Vulnerability in Multiple Schneider Electric Products (CNVD-2018-24634)
Schneider Electric Modicon M340, etc. are programmable logic controller products of Schneider Electric France. A denial of service vulnerability exists in the embedded web server in several Schneider Electric products, which can be exploited by an attacker to cause a denial of service by sending ...
Cross-site scripting vulnerability in multiple Schneider Electric products (CNVD-2018-25428)
Schneider Electric Modicon M340, etc. are programmable logic controller products of Schneider Electric France. A cross-site scripting vulnerability exists in the embedded web server in several Schneider Electric products, which can be exploited by remote attackers to execute JavaScript code in a...
Cross-site scripting vulnerability in multiple Schneider Electric products (CNVD-2018-25427)
Schneider Electric Modicon M340, etc. are programmable logic controller products of Schneider Electric France. A cross-site scripting vulnerability exists in the embedded web server in several Schneider Electric products, which can be exploited by remote attackers to change passwords on the web...
PT-2018-2169
Name of the Vulnerable Software and Affected Versions Modicon M340, Premium, Quantum PLCs and BMXNOR0200 affected versions not specified Description The issue is related to an Improper Neutralization of Input During Web Page Generation, also known as Cross-site Scripting. This allows an attacker ...
PT-2018-2170
Name of the Vulnerable Software and Affected Versions Modicon M340, Premium, Quantum PLCs versions affected versions not specified BMXNOR0200 versions affected versions not specified Description The issue is related to the lack of necessary checks when changing passwords in the programmable logic...
Modicon Quantum HTTP Server 'formTest' 'name' Parameter XSS
Binary data scadamodiconformtestxss.nbin...
PT-2018-2172
Name of the Vulnerable Software and Affected Versions Modicon M340, Premium, Quantum PLCs and BMXNOR0200 affected versions not specified Description The issue is related to an improper neutralization of script-related HTML tags in a web page, which can be exploited to execute a password change on...
PT-2018-2168
Name of the Vulnerable Software and Affected Versions Modicon M340, Premium, Quantum PLCs and BMXNOR0200 affected versions not specified Description The issue is related to an Unverified Password Change vulnerability in the embedded web servers. This could allow an unauthenticated remote user to...
PT-2018-2171
Name of the Vulnerable Software and Affected Versions Modicon M340, Premium, Quantum PLCs and BMXNOR0200 affected versions not specified Description The issue is related to improper neutralization of CRLF sequences in HTTP headers, also known as 'HTTP Response Splitting'. This can lead to a denia...