Lucene search
K

10 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2017-15100

Malware in sbrugna...

5.3CVSS5.9AI score0.00153EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2017-15102

Malware in sbrugna...

9.8CVSS9.5AI score0.00098EPSS
Exploits0References3
ATTACKERKB
ATTACKERKB
added 2017/06/30 3:29 a.m.3 views

CVE-2017-6034

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

9.8CVSS7.2AI score0.00098EPSS
Exploits0References5
Prion
Prion
added 2017/06/30 3:29 a.m.9 views

Authentication flaw

An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

7.5CVSS9.2AI score0.00098EPSS
Exploits0References2
Prion
Prion
added 2017/06/30 3:29 a.m.11 views

Design/Logic Flaw

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...

5CVSS6.1AI score0.00153EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2017/06/30 2:35 a.m.2 views

CVE-2017-6034 Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

7.2AI score0.00098EPSS
Exploits0References4
CVE
CVE
added 2017/06/30 2:35 a.m.44 views

CVE-2017-6034

CVE-2017-6034 affects Schneider Electric Modicon Modbus Protocol. The vulnerability is an Authentication Bypass by Capture-Replay, enabling an attacker to replay sensitive Modbus commands (run/stop/upload/download) with cleartext traffic and network access. The issue is associated with the Modico...

9.8CVSS7.2AI score0.00098EPSS
Exploits0References4Affected Software1
Positive Technologies
Positive Technologies
added 2017/04/11 12:0 a.m.3 views

PT-2017-3786

Name of the Vulnerable Software and Affected Versions Schneider Electric Modicon Modbus Protocol affected versions not specified Description An Authentication Bypass by Capture-Replay issue was discovered, where sensitive information is transmitted in cleartext in the Modicon Modbus protocol. Thi...

10CVSS7.3AI score0.00098EPSS
Exploits0References5
ICS
ICS
added 2017/04/11 12:0 a.m.84 views

Schneider Electric Modicon Modbus Protocol

CVSS v3 10.0 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Modicon Modbus Protocol Vulnerabilities: Authentication Bypass by Capture-Replay, Violation of Secure Design Principles AFFECTED PRODUCTS The following versions of Modicon Modbus protoco...

9.8CVSS7.3AI score0.00153EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2017/02/28 12:0 a.m.24 views

Modicon Modbus/TCP UnityPro Programming Function Code Access

Binary data scadamodbusmodiconproject.nbin...

7.3AI score
Exploits0
Rows per page