CVE-2017-7905

A Weak Cryptography for Passwords issue was discovered in General Electric GE Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Versio...

9.8CVSS5.8AI score0.01281EPSS
Exploits0References2
Prion
Prion
added 2017/06/30 3:29 a.m.16 views

Authentication flaw

An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

7.5CVSS9.2AI score0.05139EPSS
Exploits0References2
Prion
Prion
added 2017/06/30 3:29 a.m.15 views

Design/Logic Flaw

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...

5CVSS6.1AI score0.0165EPSS
Exploits0References2
NVD
NVD
added 2017/06/30 3:29 a.m.23 views

CVE-2017-6032

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...

5.3CVSS6.2AI score0.0165EPSS
Exploits0References2
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.34 views

CVE-2017-6034 Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

9.3AI score0.05139EPSS
Exploits0References4
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.29 views

CVE-2017-6032

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...

5.2AI score0.0165EPSS
Exploits0References2
CVE
CVE
added 2017/06/30 2:35 a.m.60 views

CVE-2017-6032

CVE-2017-6032 concerns Schneider Electric Modicon Modbus Protocol: a session-related weakness in Modbus that may allow brute-force-style access. Affected component: Modbus protocol in Schneider Electric Modicon PLCs; impact described as potential exposure of control commands with low to moderate ...

5.3CVSS5.2AI score0.0165EPSS
Exploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2017/06/30 2:35 a.m.6 views

CVE-2017-6034 Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

7.2AI score0.05139EPSS
Exploits0References4
CVE
CVE
added 2017/06/30 2:35 a.m.53 views

CVE-2017-6034

CVE-2017-6034 affects Schneider Electric Modicon Modbus Protocol. The vulnerability is an Authentication Bypass by Capture-Replay, enabling an attacker to replay sensitive Modbus commands (run/stop/upload/download) with cleartext traffic and network access. The issue is associated with the Modico...

9.8CVSS7.2AI score0.05139EPSS
Exploits0References4Affected Software1
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.23 views

CVE-2017-7905

A Weak Cryptography for Passwords issue was discovered in General Electric GE Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Versio...

9.3AI score0.01281EPSS
Exploits0References2
VulnCheck KEV
VulnCheck KEV
added 2017/06/12 12:0 a.m.3 views

VulnCheck KEV: CVE-2015-5374

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant...

7.8CVSS7.3AI score0.74323EPSS
Exploits7References1
OpenVAS
OpenVAS
added 2017/06/02 12:0 a.m.15 views

Advantech MESR901 Detection

Detection of Advantech MESR901 Industrial Modbus Copper Ethernet to Serial Gateway. The script sends a connection request to the server and attempts to detect Advantech MESR901 Modbus Gateway devices and to extract its firmware version. SPDX-FileCopyrightText: 2017 Greenbone AG Some text...

7AI score
Exploits0References1
CNVD
CNVD
added 2017/05/03 12:0 a.m.4 views

Advantech B + B SmartWorx MESR901 Authentication Bypass Vulnerability

Advantech B + B SmartWorx MESR901 is a Modbus gateway. An authentication bypass vulnerability exists in Advantech B + B SmartWorx MESR901. An attacker can exploit the vulnerability to carry out authentication mechanisms and perform unauthorized operations, leading to further attacks...

9.8CVSS7.1AI score0.02616EPSS
Exploits0References1
ICS
ICS
added 2017/05/02 12:0 a.m.38 views

Advantech B+B SmartWorx MESR901

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Advantech B+B SmartWorx Equipment: MESR901 Vulnerability: Use of Client-Side Authentication AFFECTED PRODUCTS The following versions of MESR901, a Modbus gateway, are affected: MESR901 firmware versions 1.5.2 and prio...

9.8CVSS10AI score0.02616EPSS
Exploits0References3
CNVD
CNVD
added 2017/05/01 12:0 a.m.3 views

GE Multilin SR Relay Unauthorized Access Vulnerability

The 750 Feeder/760 Feeder/469 Motor/489 Generator/745 Transformer/369 Motor are all a GE relay. An unauthorized access vulnerability exists in the GE Multilin SR relays, which could allow an attacker to gain unauthorized access to the GE MultilinSR series of relay products by brute-force cracking...

8.8CVSS8.8AI score0.01603EPSS
Exploits1References1
ICS
ICS
added 2017/04/27 12:0 a.m.68 views

GE Multilin SR, UR, and URplus Protective Relays (Update B)

CVSS v3 8.1 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: Multilin SR, UR, and URplus Protective Relays Vulnerabilities: Weak Cryptography for Passwords UPDATED INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-17-117-01A GE...

9.8CVSS9.9AI score0.01281EPSS
Exploits0References3
CNVD
CNVD
added 2017/04/18 12:0 a.m.4 views

Schneider Electric Modicon TM221CE16R Information Disclosure Vulnerability

The Schneider Electric Modicon TM221CE16R is a programmable controller from Schneider Electric France. A security vulnerability exists in the Schneider Electric Modicon TM221CE16R version 1.3.3.3. A remote attacker can exploit this vulnerability by sending a...

9.8CVSS7.2AI score0.03981EPSS
Exploits1References1
Positive Technologies
Positive Technologies
added 2017/04/11 12:0 a.m.16 views

PT-2017-3786

Name of the Vulnerable Software and Affected Versions Schneider Electric Modicon Modbus Protocol affected versions not specified Description An Authentication Bypass by Capture-Replay issue was discovered, where sensitive information is transmitted in cleartext in the Modicon Modbus protocol. Thi...

10CVSS7.3AI score0.05139EPSS
Exploits0References8
0day.today
0day.today
added 2017/04/11 12:0 a.m.108 views

Anybus Modbus Gateway - Authenticated Directory Traversal Vulnerability

The cgi-bin/read.cgi CGI script in the cgi-bin folder on the devices webserver is vulnerable to directly traversal by directly including any file. It typically includes files from the /home/httpd/jjs directoy but you can access files outside of the main webserver directory. There's 67 of these...

7AI score
Exploits0
ICS
ICS
added 2017/04/11 12:0 a.m.95 views

Schneider Electric Modicon Modbus Protocol

CVSS v3 10.0 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Modicon Modbus Protocol Vulnerabilities: Authentication Bypass by Capture-Replay, Violation of Secure Design Principles AFFECTED PRODUCTS The following versions of Modicon Modbus protoco...

9.8CVSS7.3AI score0.05139EPSS
Exploits0References3