Lucene search
+L

1724 matches found

Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.28 views

Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7542)

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

7.5CVSS7.4AI score0.01322EPSS
SaveExploits0References2
NVD
NVD
added 2022/02/04 11:15 p.m.32 views

CVE-2022-22724

A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 HTTP and 502 Modbus, when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 All Versions...

7.5CVSS0.0093EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/04 11:15 p.m.23 views

CVE-2021-21964

A denial of service vulnerability exists in the Modbus configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger this vulnerability...

8.6CVSS0.00711EPSS
SaveExploits1References1
OSV
OSV
added 2022/02/04 11:15 p.m.9 views

CVE-2021-21964

A denial of service vulnerability exists in the Modbus configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger this vulnerability...

7.4CVSS5.8AI score0.00711EPSS
SaveExploits1References1
Prion
Prion
added 2022/02/04 11:15 p.m.22 views

Denial of service

A denial of service vulnerability exists in the Modbus configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger this vulnerability...

7.1CVSS7.4AI score0.00711EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2022/02/04 10:29 p.m.86 views

CVE-2022-22724

CVE-2022-22724 affects Schneider Electric Modicon M340 BMXP34 controllers (all versions). The root cause is CWE-400 Uncontrolled Resource Consumption, enabling a denial of service by flooding TCP ports 80 (HTTP) and 502 (Modbus) with a large number of RST/FIN packets to any open TCP port. Documen...

7.5CVSS7.4AI score0.0093EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/02/04 10:29 p.m.36 views

CVE-2022-22724

A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 HTTP and 502 Modbus, when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 All Versions...

7.6AI score0.0093EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/02/04 10:29 p.m.48 views

CVE-2021-21964

A denial of service vulnerability exists in the Modbus configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger this vulnerability...

8.6CVSS7.7AI score0.00711EPSS
SaveExploits1References1
CVE
CVE
added 2022/02/04 10:29 p.m.72 views

CVE-2021-21964

SeaConnect 370W v1.3.34 is affected by CVE-2021-21964. TALOS details two denial-of-service vectors in Modbus/SeaMAX Remote Configuration: unauthenticated Modbus over TCP (port 502) and SeaMAX API over UDP (port 30718). An attacker can remotely trigger reboot or alter configuration through crafted...

8.6CVSS7.2AI score0.00711EPSS
SaveExploits1References1Affected Software1
Positive Technologies
Positive Technologies
added 2022/02/04 12:0 a.m.11 views

PT-2022-9218 · Unknown · Seaconnect 370W

Name of the Vulnerable Software and Affected Versions: SeaConnect 370W version 1.3.34 Description: A denial of service issue exists in the Modbus configuration functionality. Specially-crafted network packets can cause a denial of service. An attacker can send a malicious packet to trigger this...

8.6CVSS7.6AI score0.00711EPSS
SaveExploits1References2
CNNVD
CNNVD
added 2022/02/04 12:0 a.m.10 views

Schneider Electric Modicon M340 资源管理错误漏洞

Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. The vulnerability can be exploited to send a large number of TCP RST or FIN packets to any open TCP port of the PLC, resulting in a denial ...

7.5CVSS5.7AI score0.0093EPSS
SaveExploits0References2
Talos
Talos
added 2022/02/01 12:0 a.m.62 views

Sealevel Systems, Inc. SeaConnect 370W Modbus/SeaMAX Remote Configuration denial of service vulnerabilities

Summary Two denial of service vulnerabilities exist in the Modbus/SeaMAX Remote Configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger these vulnerabilities...

9.3CVSS8.4AI score0.01021EPSS
SaveExploits2
Talos
Talos
added 2022/02/01 12:0 a.m.55 views

Sealevel Systems, Inc. SeaConnect 370W OTA update task file overwrite vulnerability

Summary A file write vulnerability exists in the OTA update task functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. A specially-crafted MQTT payload can lead to arbitrary file overwrite. An attacker can perform a man-in-the-middle attack to trigger this vulnerability. Tested Version...

8.3CVSS8.2AI score0.00952EPSS
SaveExploits1
OSV
OSV
added 2022/01/28 8:15 p.m.9 views

CVE-2021-22816

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...

7.5CVSS5.8AI score0.00947EPSS
SaveExploits0References1
NVD
NVD
added 2022/01/28 8:15 p.m.17 views

CVE-2021-22816

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...

7.8CVSS0.00947EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2022/01/28 8:15 p.m.5 views

CVE-2021-22816

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...

7.8CVSS7.1AI score0.00947EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2022/01/28 7:9 p.m.29 views

CVE-2021-22816

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...

7.7AI score0.00947EPSS
SaveExploits0References1
CVE
CVE
added 2022/01/28 7:9 p.m.63 views

CVE-2021-22816

The CVE-2021-22816 issue affects Schneider Electric SCADAPack RTUs (models 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E, 357E) running firmware 8.18.1 and earlier. The root cause is an improper check for unusual or exceptional conditions (CWE-754) that can lead to a Denial of Service when the R...

7.8CVSS7.5AI score0.00947EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/01/28 12:0 a.m.10 views

SCADAPack 代码问题漏洞

SCADAPack is a Schneider-electric intelligent field controller that combines the monitoring and communication capabilities of a Remote Terminal Unit RTU with the processing and data logging capabilities of a Programmable Logic Controller PLC to provide superior functionality for remote processes...

7.8CVSS7.5AI score0.00947EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2022/01/27 12:0 a.m.60 views

Cisco Firepower Threat Defense Snort Modbus DoS (cisco-sa-snort-dos-9D3hJLuj)

According to its self-reported version, Cisco FTD Software is affected by a denial of service DoS vulnerability in its Snort Modbus component due to an integer overflow. An unauthenticated, remote attacker can exploit this issue to cause the Snort process to stop responding. Please see the includ...

7.5CVSS6.2AI score0.01386EPSS
SaveExploits0References6
Rows per page