Lucene search
+L

21 matches found

Positive Technologies
Positive Technologies
•added 2026/08/11 12:00 a.m.•7 views

PT-2026-80494

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

9.8CVSS6AI score0.00562EPSS
SaveExploits0References6
EUVD
EUVD
•added 2025/10/03 8:07 p.m.•12 views

EUVD-2021-8411

Malicious code in bioql PyPI...

7.5CVSS7AI score0.00961EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/05/22 10:30 p.m.•21 views

CVE-2022-24322

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data...

5.9CVSS6.8AI score0.00644EPSS
SaveExploits0References1
NVD
NVD
•added 2025/02/27 12:15 p.m.•21 views

CVE-2024-10918

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

9.8CVSS0.00562EPSS
SaveExploits0References3
osv_ubuntu
osv_ubuntu
•added 2025/02/27 12:15 p.m.•24 views

UBUNTU-CVE-2024-10918

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

9.8CVSS6AI score0.00562EPSS
SaveExploits0References6
CVE
CVE
•added 2025/02/27 11:44 a.m.•121 views

CVE-2024-10918

CVE-2024-10918 is a stack-based buffer overflow in libmodbus (v3.1.10) that can occur when replying to a Modbus request with an unexpected length, overflowing the buffer allocated for the response. The vulnerability is confirmed in multiple sources (NVD/NVD-listed, Debian DLA 4084-1, and related ...

9.8CVSS5.5AI score0.00562EPSS
SaveExploits0References3Affected Software1
Vulnrichment
Vulnrichment
•added 2025/02/27 11:44 a.m.•13 views

CVE-2024-10918 Stack-based Buffer Overflow in libmodbus library

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

4.8CVSS5.4AI score0.00562EPSS
SaveExploits0References1
osv_cve
osv_cve
•added 2025/02/27 11:44 a.m.•27 views

CVE-2024-10918 Stack-based Buffer Overflow in libmodbus library

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

4.8CVSS6.1AI score0.00562EPSS
SaveExploits0References7
Mend
Mend
•added 2025/02/27 11:44 a.m.•3 views

CVE-2024-10918

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

9.8CVSS0.00562EPSS
SaveExploits0References8
Cvelist
Cvelist
•added 2025/02/27 11:44 a.m.•58 views

CVE-2024-10918 Stack-based Buffer Overflow in libmodbus library

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

4.8CVSS0.00562EPSS
SaveExploits0References1
AlpineLinux
AlpineLinux
•added 2025/02/27 11:44 a.m.•23 views

CVE-2024-10918

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

9.8CVSS7.7AI score0.00562EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/02/27 12:00 a.m.•2 views

CVE-2024-10918: Stack-based Buffer Overflow

Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length...

9.8CVSS5.9AI score0.00562EPSS
SaveExploits0References4
NVD
NVD
•added 2022/03/09 11:15 p.m.•32 views

CVE-2022-24323

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product:...

5.9CVSS0.0086EPSS
SaveExploits0References1
Prion
Prion
•added 2022/03/09 11:15 p.m.•32 views

Design/Logic Flaw

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product:...

4.3CVSS5.7AI score0.0086EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
•added 2022/03/09 11:05 p.m.•45 views

CVE-2022-24322

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data...

5.3CVSS5.9AI score0.00644EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2022/03/09 12:00 a.m.•7 views

PT-2022-16607

Name of the Vulnerable Software and Affected Versions EcoStruxure Control Expert versions V15.0 SP1 and prior Description A memory buffer issue exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept a...

5.9CVSS0.00644EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/03/09 12:00 a.m.•11 views

CVE-2022-24322: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data...

5.9CVSS6.1AI score0.00644EPSS
SaveExploits0References3
NVD
NVD
•added 2011/01/28 4:00 p.m.•25 views

CVE-2010-4709

Heap-based buffer overflow in Automated Solutions Modbus/TCP Master OPC Server before 3.0.2 allows remote attackers to cause a denial of service crash and possibly execute arbitrary code via a MODBUS response packet with a crafted length field...

7.6CVSS8.1AI score0.16195EPSS
SaveExploits2References8
Prion
Prion
•added 2011/01/28 4:00 p.m.•23 views

Heap overflow

Heap-based buffer overflow in Automated Solutions Modbus/TCP Master OPC Server before 3.0.2 allows remote attackers to cause a denial of service crash and possibly execute arbitrary code via a MODBUS response packet with a crafted length field...

7.6CVSS8.7AI score0.16195EPSS
SaveExploits2References8Affected Software1
Positive Technologies
Positive Technologies
•added 2011/01/28 12:00 a.m.•9 views

PT-2011-1659

Name of the Vulnerable Software and Affected Versions Automated Solutions Modbus/TCP Master OPC Server versions prior to 3.0.2 Description The issue is related to a heap-based buffer overflow that can be triggered by a MODBUS response packet with a crafted length field. This can cause a denial of...

7.6CVSS0.16195EPSS
SaveExploits2References10
Rows per page
Query Builder