Lucene search
+L

236 matches found

CNVD
CNVD
•added 2018/04/13 12:00 a.m.•8 views

Denial of Service Vulnerability in the Hologic LE5109L PLC

HELISE Group is a professional automation company integrating R&D, production, sales and technical service. With integrated Ethernet, PROFIBUS-DP, RS232 and RS485 interfaces, HELISE's PLCs have been widely used in electric power, chemical industry, metallurgy, energy and other fields. A denial of...

6.8AI score
SaveExploits0
CNVD
CNVD
•added 2018/04/13 12:00 a.m.•9 views

Information Disclosure Vulnerability in Hologic LE5109L PLCs

HELISE Group is a professional automation company integrating R&D, production, sales and technical service. With integrated Ethernet, PROFIBUS-DP, RS232 and RS485 interfaces, HELISE's PLCs have been widely used in electric power, chemical industry, metallurgy, energy and other fields. An...

6.4AI score
SaveExploits0
CNVD
CNVD
•added 2017/11/21 12:00 a.m.•19 views

Belden Hirschmann Tofino Xenon Security Appliance Protocol Filter Evasion Vulnerability

The Tofino Xenon security appliance is the ideal solution for segmenting control networks into secure zones. A protocol filter evasion vulnerability exists in the Tofino Xenon security appliance prior to version 03.2.00. The vulnerability arises because the ModBus DPI filter improperly handles th...

9.8CVSS7AI score0.01397EPSS
SaveExploits0References1
OSV
OSV
•added 2017/11/20 3:29 p.m.•18 views

CVE-2017-11401

An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Improper handling of the mbap.length field of ModBus packets in the ModBus DPI filter allows an attacker to send malformed/crafted packets to a protected asset, bypassing function code filtering...

9.8CVSS5.8AI score0.01397EPSS
SaveExploits0References2
NVD
NVD
•added 2017/06/30 3:29 a.m.•33 views

CVE-2017-6032

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...

5.3CVSS6.2AI score0.0165EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2017/06/30 2:35 a.m.•46 views

CVE-2017-6034 Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

9.3AI score0.05181EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2017/06/30 2:35 a.m.•43 views

CVE-2017-6032

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...

5.2AI score0.0165EPSS
SaveExploits0References2
CVE
CVE
•added 2017/06/30 2:35 a.m.•75 views

CVE-2017-6032

CVE-2017-6032 concerns Schneider Electric Modicon Modbus Protocol: a session-related weakness in Modbus that may allow brute-force-style access. Affected component: Modbus protocol in Schneider Electric Modicon PLCs; impact described as potential exposure of control commands with low to moderate ...

5.3CVSS5.2AI score0.0165EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/06/30 12:00 a.m.•6 views

CVE-2017-6034: Authentication Bypass by Capture-replay

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...

9.8CVSS8.1AI score0.05181EPSS
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/06/30 12:00 a.m.•8 views

CVE-2017-6032: Violation of Secure Design Principles

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...

5.3CVSS6.4AI score0.0165EPSS
SaveExploits0References3
VulnCheck KEV
VulnCheck KEV
•added 2017/06/12 12:00 a.m.•10 views

VulnCheck KEV: CVE-2015-5374

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

7.8CVSS7AI score0.74497EPSS
SaveIn wildExploits7References4
OpenVAS
OpenVAS
•added 2017/01/26 12:00 a.m.•35 views

Schneider Electric Devices Detection (Modbus)

Modbus protocol based detection of Schneider Electric devices. SPDX-FileCopyrightText: 2017 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

5.8AI score
SaveExploits0References1
CNVD
CNVD
•added 2016/08/20 12:00 a.m.•5 views

Shanghai Xunrao X2Cloud Cloud Gateway Denial of Service Vulnerability

X2Cloud cloud gateway is a cloud gateway product of Shanghai Xunrao Company. The gateway collects data and then stores the data to the cloud platform, which sends the data to the outside through Modbus TCP interface or its own Web interface. Shanghai Xunrao X2Cloud cloud gateway denial of service...

6.8AI score
SaveExploits0
Fedora
Fedora
•added 2016/03/09 8:19 p.m.•20 views

[SECURITY] Fedora 23 Update: libmodbus-3.0.6-1.fc23

libmodbus is a C library designed to provide a fast and robust implementati on of the Modbus protocol. It runs on Linux, Mac OS X, FreeBSD, QNX and Windows. This package contains the libmodbus shared library...

2.8AI score
SaveExploits0
Fedora
Fedora
•added 2016/03/09 8:15 p.m.•20 views

[SECURITY] Fedora 22 Update: libmodbus-3.0.6-1.fc22

libmodbus is a C library designed to provide a fast and robust implementati on of the Modbus protocol. It runs on Linux, Mac OS X, FreeBSD, QNX and Windows. This package contains the libmodbus shared library...

2.8AI score
SaveExploits0
Metasploit
Metasploit
•added 2013/08/30 9:28 p.m.•93 views

Modbus Client Utility

This module allows reading and writing data to a PLC using the Modbus protocol. This module is based on the 'modiconstop.rb' Basecamp module from DigitalBond, as well as the mbtget perl script. This module requires Metasploit: https://metasploit.com/download Current source:...

7.2AI score
SaveExploits0
Rows per page