6911 matches found
CVE-2021-22805
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...
CVE-2021-22823
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...
CVE-2021-22805
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...
Authentication flaw
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...
CVE-2021-22823
CVE-2021-22823 affects Schneider Electric IGSS Interactive Graphical SCADA System Data Collector (dc.exe) on v15.0.0.21320 and earlier. It is a CWE-306 Missing Authentication for Critical Function vulnerability caused by lack of validation of network messages, which could lead to deletion of arbi...
PT-2022-9291
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Collector dc.exe version 15.0.0.21320 and prior Description A Missing Authentication for Critical Function issue exists due to lack of validation of network messages, which could cause deletion of...
CVE-2021-22823: Missing Authentication for Critical Function
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...
CVE-2021-22805: Missing Authentication for Critical Function
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...
CVE-2022-24111: Missing Authentication for Critical Function
In Mahara 21.04 before 21.04.3 and 21.10 before 21.10.1, portfolios created in groups that have not been shared with non-group members and portfolios created on the site and institution levels can be viewed without requiring a login if the URL to these portfolios is known...
CVE-2021-31814: Missing Authentication for Critical Function
In Stormshield 1.1.0, and 2.1.0 through 2.9.0, an attacker can block a client from accessing the VPN and can obtain sensitive information through the SN VPN SSL Client...
CVE-2022-22809
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk V2.6.2 and prior, Wiser for KNX formerly...
CVE-2022-22809
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk V2.6.2 and prior, Wiser for KNX formerly...
Authentication flaw
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk V2.6.2 and prior, Wiser for KNX formerly...
CVE-2022-21660
Gin-vue-admin is a backstage management system based on vue and gin. In versions prior to 2.4.7 low privilege users are able to modify higher privilege users. Authentication is missing on the "setUserInfo" function. Users are advised to update as soon as possible. There are no known workarounds...
CVE-2022-22809
CVE-2022-22809 describes a CWE-306 Missing Authentication for Critical Function affecting Schneider Electric spaceLYnk, Wiser for KNX (formerly homeLYnk), and fellerLYnk, all with version 2.6.2 and prior. The issue allows unauthorized modification of touch configurations due to missing authentica...
CVE-2022-22809: Missing Authentication for Critical Function
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk V2.6.2 and prior, Wiser for KNX formerly...
Siemens SICAM MMU, SICAM T, and SICAM SGU Missing Authentication For Critical Function (CVE-2020-10038)
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the device's web server might be able to execute administrative commands without authentication. This plugin only works with Tenable.ot. Please visit...
Siemens SICAM MMU, SICAM T, and SICAM SGU Missing Authentication For Critical Function (CVE-2020-10044)
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the network could be able to install specially crafted firmware to the device. This plugin only works with Tenable.ot. Please visit...
Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module Missing Authentication For Critical Function (CVE-2018-4840)
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
The vulnerability of the configuration of software solutions for Zoho ManageEngine ServiceDesk Plus, Zoho ManageEngine ServiceDesk Plus MSP, and Zoho ManageEngine SupportCenter Plus lies in the absence of authentication procedures, which allow attackers to execute arbitrary code.
The vulnerability of the configuration of software solutions for Zoho ManageEngine ServiceDesk Plus, Zoho ManageEngine ServiceDesk Plus MSP, and Zoho ManageEngine SupportCenter Plus lies in the absence of authentication procedures. Exploiting this vulnerability allows a malicious actor to execute...