Lucene search
K

9 matches found

Tenable Nessus
Tenable Nessus
added 2025/11/18 12:0 a.m.5 views

Network Mirroring in Siemens RUGGEDCOM Incorrect Provision of Specified Functionality (CVE-2023-24845)

The affected products insufficiently block data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior. This plugin onl...

9.8CVSS7.2AI score0.00261EPSS
Exploits0References5
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2019-16128

Malware in sbrugna...

9.1CVSS9AI score0.00508EPSS
Exploits0References2
Cvelist
Cvelist
added 2023/08/08 9:20 a.m.11 views

CVE-2023-24845

A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969...

9.1CVSS9.5AI score0.00261EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2023/08/08 12:0 a.m.2 views

PT-2023-4773 · Siemens · Ruggedcom Rs900 +27

Name of the Vulnerable Software and Affected Versions: RUGGEDCOM i800 versions RUGGEDCOM i801 versions RUGGEDCOM i802 versions RUGGEDCOM i803 versions RUGGEDCOM M2100 versions RUGGEDCOM M2200 versions RUGGEDCOM M969 versions RUGGEDCOM RMC30 versions RUGGEDCOM RMC8388 versions 4.X through 5.X...

9.8CVSS9.3AI score0.00261EPSS
Exploits0References5
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:0 a.m.44 views

Siemens SCALANCE X Expected Behavior Violation (CVE-2019-6569)

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime...

9.1CVSS8.3AI score0.00508EPSS
Exploits0References3
OSV
OSV
added 2019/03/26 10:29 p.m.0 views

CVE-2019-6569

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime...

9.1CVSS7.3AI score0.00508EPSS
Exploits0References1
NVD
NVD
added 2019/03/26 10:29 p.m.9 views

CVE-2019-6569

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime...

9.1CVSS9.3AI score0.00508EPSS
Exploits0References1
Cvelist
Cvelist
added 2019/03/26 9:12 p.m.13 views

CVE-2019-6569

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime...

9.2AI score0.00508EPSS
Exploits0References1
CVE
CVE
added 2019/03/26 9:12 p.m.74 views

CVE-2019-6569

CVE-2019-6569 affects Siemens SCALANCE X switches. The vulnerability (CWE-440) arises from the monitor barrier failing to block data on the mirror port, allowing data from the traffic-receiving network to be forwarded into the mirrored network and potentially influence configuration and runtime b...

9.1CVSS9.1AI score0.00508EPSS
Exploits0References1Affected Software1
Rows per page
Query Builder