added 2026/04/23 6:0 a.m.6 views

SpiceJet Online Booking System

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all...

5.5AI score
Exploits0References13
ICS
ICS
added 2026/04/21 6:0 a.m.9 views

SenseLive X3050

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to take complete control of the device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all...

5.7AI score
Exploits0References13
ICS
ICS
added 2026/03/12 6:0 a.m.8 views

Inductive Automation Ignition Software

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute malicious code with OS application service account permissions that the authenticated, privileged application user did not intend on running. 2. RECOMMENDED PRACTICES CISA recommends users take...

6.8CVSS5.9AI score0.00345EPSS
Exploits0References13
ICS
ICS
added 2026/03/03 6:0 a.m.6 views

Everon OCPP Backends

RISK EVALUATION Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. 2. RECOMMENDED PRACTICES CISA recommends users take defensive...

6AI score
Exploits0References11
ICS
ICS
added 2026/02/10 8:0 a.m.4 views

Schneider Electric SCADAPack and RemoteConnect

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access...

6.1AI score
Exploits0References11
ICS
ICS
added 2025/12/09 8:0 a.m.3 views

Schneider Electric EcoStruxure Foxboro DCS (Update A)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access...

5.9CVSS7.3AI score0.01566EPSS
Exploits0References11
ICS
ICS
added 2025/11/13 7:0 a.m.3 views

Rockwell Automation FactoryTalk Policy Manager

RISK EVALUATION Successful exploitation of this vulnerability could lead to resource exhaustion and denial of service. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all...

7.5CVSS7.4AI score0.03168EPSS
Exploits0References13
ICS
ICS
added 2025/11/13 7:0 a.m.4 views

Siemens SICAM P850 family and SICAM P855 family

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of...

6.1AI score
Exploits0References13
ICS
ICS
added 2025/09/09 6:0 a.m.4 views

Rockwell Automation CompactLogix® 5480

RISK EVALUATION Successful exploitation of this vulnerability could result in arbitrary code execution. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system...

7CVSS7.3AI score0.00188EPSS
Exploits0References10
ICS
ICS
added 2025/08/14 6:0 a.m.5 views

Rockwell Automation ArmorBlock 5000 I/O - Webserver

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to predict session numbers or perform privileged actions. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:...

7.2AI score
Exploits0References10
ICS
ICS
added 2025/08/14 6:0 a.m.10 views

Rockwell Automation Micro800

RISK EVALUATION Successful exploitation of these vulnerabilities could result in remote code execution or may lead to privilege escalation. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize...

8.5AI score
Exploits0References10
ICS
ICS
added 2025/08/12 12:0 a.m.9 views

Siemens SIMATIC RTLS Locating Manager

SUMMARY Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate...

7.7AI score
Exploits0References10