Lucene search
+L

142 matches found

CVE
CVE
added 2019/12/12 7:8 p.m.64 views

CVE-2019-18300

Summary: CVE-2019-18300 family (SPPA-T3000 MS3000 Migration Server, all versions) can be abused by a network-reachable attacker who sends specially crafted packets to port 5010/tcp to trigger a Denial-of-Service. Red Hat advisories for related CVEs (CVE-2019-18301, 18302, 18303, 18304, 18305, 183...

7.5CVSS7.1AI score0.02475EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2019/12/12 7:8 p.m.60 views

CVE-2019-18301

Summary of CVE-2019-18301 / related RH advisories : The SPPA-T3000 MS3000 Migration Server (all versions) is vulnerable to a network-based Denial-of-Service. An attacker with network access can trigger the condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is s...

7.5CVSS7.1AI score0.02475EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2019/12/12 7:8 p.m.68 views

CVE-2019-18289

Summary (CVE-2019-18289 / related CVEs): SPPA-T3000 MS3000 Migration Server (all versions) is vulnerable to a network-accessible issue on 5010/tcp. A crafted packet could cause a Denial-of-Service and may lead to remote code execution. Attacker requires network access; no user interaction. Connec...

9.8CVSS9.5AI score0.04926EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2019/12/12 7:8 p.m.71 views

CVE-2019-18290

CVE-2019-18303 (and related CVEs) describe a Denial-of-Service vulnerability in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access can trigger a DoS by sending specially crafted packets to port 5010/tcp. The Red Hat advisories confirm the issue is independent of ot...

7.5CVSS7.1AI score0.02475EPSS
Exploits0References2Affected Software1
CNVD
CNVD
added 2019/12/11 12:0 a.m.4 views

Siemens SPPA-T3000 MS3000 Migration Server Incorrect Access Control Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. It allows an attacker with local...

7.8CVSS6.8AI score0.00315EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.1 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability (CNVD-2019-45423)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02475EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.2 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45411)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...

9.8CVSS8.2AI score0.04926EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.5 views

Siemens SPPA-T3000 MS3000 Migration Server Improper Authentication Vulnerability (CNVD-2019-45376)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with network access ...

5.3CVSS6.8AI score0.01078EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.4 views

Siemens SPPA-T3000 MS3000 Migration Server File Upload Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with network access ...

9.8CVSS7.9AI score0.02793EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.6 views

Siemens SPPA-T3000 MS3000 Migration Server Out-of-Bounds Read Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An out-of-bounds read vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...

7.5CVSS6.7AI score0.02502EPSS
Exploits1References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.2 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45418)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...

9.8CVSS8.2AI score0.04926EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.0 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45419)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. Siemens SPPA-T3000 MS3000 Migration Server heap buffer overflow vulnerability. Allows an attacker with network acce...

9.8CVSS8.2AI score0.04926EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.2 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45417)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with loc...

7.8CVSS7.2AI score0.00747EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.5 views

Siemens SPPA-T3000 MS3000 Migration Server Incorrect Access Control Vulnerability (CNVD-2019-45386)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. It allows an attacker with local...

7.8CVSS6.8AI score0.00315EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.4 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...

7.5CVSS7.1AI score0.01241EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.4 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45410)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...

7.5CVSS7.1AI score0.02475EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.4 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability (CNVD-2019-45384)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02475EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.4 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02502EPSS
Exploits1References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.5 views

Siemens SPPA-T3000 MS3000 Migration Server Denial of Service Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with network access ...

7.5CVSS6.7AI score0.015EPSS
Exploits0References1
CNVD
CNVD
added 2019/12/11 12:0 a.m.7 views

Siemens SSPPA-T3000 MS3000 Migration Server Out-of-Bounds Read Vulnerability (CNVD-2019-45371)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An out-of-bounds read vulnerability exists in the Siemens SSPPA-T3000 MS3000 Migration Server. An attacker with...

7.5CVSS6.7AI score0.02475EPSS
Exploits0References1
Rows per page