Lucene search
+L

49 matches found

CNNVD
CNNVD
added 2022/04/27 12:0 a.m.5 views

Miele Benchmark Programming Tool 安全漏洞

Miele Benchmark Programming Tool is a desktop application from Miele Germany. It allows users to easily edit washing machine and tumble dryer programs and machine settings on their Miele Professional devices. A security vulnerability exists in Miele Benchmark Programming Tool versions prior to...

7.3CVSS7.3AI score0.00521EPSS
SaveExploits2References7
ATTACKERKB
ATTACKERKB
added 2022/04/27 12:0 a.m.6 views

CVE-2022-22521

In Miele Benchmark Programming Tool with versions Prior to 1.2.71, executable files manipulated by attackers are unknowingly executed with users privileges. An attacker with low privileges may trick a user with administrative privileges to execute these binaries as admin...

7.3CVSS7.2AI score0.00521EPSS
SaveExploits2References5Affected Software1
OSV
OSV
added 2020/02/24 3:15 p.m.5 views

CVE-2019-20481

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, the Password Change Function does not require knowledge of the old password. This can be exploited in conjunction with CVE-2019-20480...

9.8CVSS6AI score0.00587EPSS
SaveExploits0References1
NVD
NVD
added 2020/02/24 3:15 p.m.27 views

CVE-2019-20481

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, the Password Change Function does not require knowledge of the old password. This can be exploited in conjunction with CVE-2019-20480...

9.8CVSS6.4AI score0.00587EPSS
SaveExploits0References1
NVD
NVD
added 2020/02/24 3:15 p.m.35 views

CVE-2019-20480

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, a malicious website visited by an authenticated admin user or a malicious mail is allowed to make arbitrary changes in the "admin panel" because there is no CSRF protection...

8.8CVSS6.4AI score0.00356EPSS
SaveExploits0References1
OSV
OSV
added 2020/02/24 3:15 p.m.7 views

CVE-2019-20480

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, a malicious website visited by an authenticated admin user or a malicious mail is allowed to make arbitrary changes in the "admin panel" because there is no CSRF protection...

8.8CVSS6.2AI score0.00356EPSS
SaveExploits0References1
Prion
Prion
added 2020/02/24 3:15 p.m.18 views

Cross site request forgery (csrf)

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, a malicious website visited by an authenticated admin user or a malicious mail is allowed to make arbitrary changes in the "admin panel" because there is no CSRF protection...

6.8CVSS9.1AI score0.00356EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2020/02/24 3:15 p.m.16 views

Design/Logic Flaw

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, the Password Change Function does not require knowledge of the old password. This can be exploited in conjunction with CVE-2019-20480...

5CVSS8.6AI score0.00587EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/02/24 2:35 p.m.44 views

CVE-2019-20480

CVE-2019-20480 affects the MIELE XGW 3000 ZigBee Gateway prior to version 2.4.0. The vulnerability is a lack of CSRF protection, allowing an authenticated admin user (or a malicious email) to trigger arbitrary changes in the device’s admin panel by visiting a malicious site. This can enable unaut...

8.8CVSS9AI score0.00356EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/02/24 2:35 p.m.35 views

CVE-2019-20480

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, a malicious website visited by an authenticated admin user or a malicious mail is allowed to make arbitrary changes in the "admin panel" because there is no CSRF protection...

4.6CVSS6.4AI score0.00356EPSS
SaveExploits0References1
CVE
CVE
added 2020/02/24 2:35 p.m.46 views

CVE-2019-20481

The connected Red Hat advisories confirm CVE-2019-20481 affects the Miele XGW 3000 ZigBee Gateway before 2.4.0, where the Password Change Function does not require the old password. This is stated to be exploitable in conjunction with CVE-2019-20480 (CSRF). The combined entries indicate an auth-r...

9.8CVSS8.6AI score0.00587EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/02/24 2:35 p.m.28 views

CVE-2019-20481

In MIELE XGW 3000 ZigBee Gateway before 2.4.0, the Password Change Function does not require knowledge of the old password. This can be exploited in conjunction with CVE-2019-20480...

4.6CVSS6.5AI score0.00587EPSS
SaveExploits0References1
Openbugbounty
Openbugbounty
added 2018/01/25 8:2 p.m.18 views

www4.miele.de XSS vulnerability

Open Bug Bounty ID: OBB-546405 Description| Value ---|--- Affected Website:| www4.miele.de Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1...

6.3AI score
SaveExploits0
ICS
ICS
added 2017/05/18 12:0 a.m.58 views

ICSA-17-138-01_Miele Professional PG 85 Series

CVSS v3 7.3 ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available. Vendor: Miele Professional Equipment: PG 85 Series Vulnerability: Path Traversal UPDATED INFORMATION This advisory is a follow-up to the original alert titled ICS-ALERT-17-089-01 Miele...

7.5CVSS7.8AI score0.1741EPSS
SaveExploits6References2
Openbugbounty
Openbugbounty
added 2017/05/07 5:24 a.m.9 views

libragroup.org XSS vulnerability

Open Bug Bounty ID: OBB-233046 Description| Value ---|--- Affected Website:| libragroup.org Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1...

6.3AI score
SaveExploits0
myhack58
myhack58
added 2017/04/01 12:0 a.m.74 views

“Dishwasher”was traced to a directory traversal vulnerability, an IOT security is getting worse and worse-vulnerability warning-the black bar safety net

Although the IOT the number of devices increases exponentially, but these smart devices security level has not increased, the user still faces a high cyber-attack risk. Miele Miele was founded in Germany one hundred years of home appliance brand, recently one model for PG8528 networked medical...

5CVSS7.6AI score0.1741EPSS
SaveExploits6
CNVD
CNVD
added 2017/03/31 12:0 a.m.8 views

Miele Professional PG 8528 PST10 Directory Traversal Vulnerability

The Miele Professional PG 8528 PST10 is a washing machine sanitizer. A directory traversal vulnerability exists in the Miele Professional PG 8528 PST10. An attacker could exploit the vulnerability to access sensitive information...

7.5CVSS6.8AI score0.1741EPSS
SaveExploits6References1
OpenVAS
OpenVAS
added 2017/03/29 12:0 a.m.28 views

Miele Professional PG 8528 Directory Traversal Vulnerability (Mar 2017)

Miele Professional PG 8528 devices are prone to a directory traversal vulnerability. Copyright C 2017 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This...

7.5CVSS7.5AI score0.1741EPSS
SaveExploits6References4
The Hacker News
The Hacker News
added 2017/03/27 1:38 a.m.38 views

Internet-Connected Medical Washer-Disinfector Found Vulnerable to Hacking

Internet-of-Things devices are turning every industry into the computer industry, making customers think that their lives would be much easier with smart devices. There are, of course, some really good reasons to connect certain devices to the Internet. For example, remotely switching on your A/C...

5CVSS7.7AI score0.1741EPSS
SaveExploits6
seebug.org
seebug.org
added 2017/03/27 12:0 a.m.43 views

Miele Professional PG 8528 - Web Server Directory Traversal(CVE-2017-7240)

Risk Information: Risk Factor: Medium CVSS Base Score: 5.0 CVSS Vector: CVSS2AV:N/AC:L/Au:N/C:P/I:N/A:N CVSS Temporal Vector: CVSS2E:POC/RL:OF/RC:C CVSS Temporal Score: 3.9 Timeline: 2016-11-16 Vulnerability discovered 2016-11-10 Asked for security contact 2016-11-21 Contact with Miele product...

5CVSS7.2AI score0.1741EPSS
SaveExploits6
Rows per page
Query Builder