Rockwell Automation MicroLogix Improper Authentication (CVE-2017-12092)
An exploitable file write vulnerability exists in the memory module functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a file write resulting in a new program being written to the memory module. An attacker can send an unauthenticated...
Rockwell Automation MicroLogix 1100 Controllers Improper Input Validation (CVE-2017-7924)
An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands PCCC packet to the...
Rockwell Automation MicroLogix Improper Authentication (CVE-2017-12090)
An exploitable denial of service vulnerability exists in the processing of snmp-set commands of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted snmp-set request, when sent without associated firmware flashing snmp-set commands, can cause a device power cycle...
Rockwell Automation MicroLogix 1400 Buffer Copy Without Checking Size of Input (CVE-2021-22659)
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...
Rockwell Automation Micro800 and MicroLogix 1400 Channel Accessible By Non-Endpoint (CVE-2021-32926)
When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14467)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14473)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Improper Restriction of Excessive Authentication Attempts (CVE-2017-7898)
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions;...
Rockwell Automation Micrologix Privilege escalation and Denial of Service (CVE-2009-3739)
Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service halt via unknown vectors. This plugin only works with Tenable.ot. Please visit...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14468)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Rockwell Automation MicroLogix Cross-site Scripting (CVE-2015-6488)
Cross-site scripting XSS vulnerability in the web server on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14469)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14466)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Rockwellautomation Micrologix Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...
Rockwellautomation Micrologix Unspecified Vulnerability
An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000...
Rockwellautomation Micrologix Channel Accessible by Non-Endpoint
When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...
CVE-2021-33012
Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...
Denial of service
Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...
CVE-2021-33012
CVE-2021-33012 affects Rockwell Automation MicroLogix 1100 (all versions). A remote, unauthenticated attacker can send specially crafted commands to cause the PLC to fault when switched to RUN mode, yielding a denial-of-service condition. Root cause: Improper Input Validation (CWE-20). As per CIS...
CVE-2021-33012
Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...