Lucene search
+L

97 matches found

NVD
NVD
added 2025/06/24 12:15 p.m.6 views

CVE-2025-39202

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption...

8.3CVSS0.00211EPSS
Exploits0References1
OSV
OSV
added 2025/06/24 12:15 p.m.6 views

CVE-2025-39201

A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service...

6.1CVSS5.8AI score
Exploits0References1
NVD
NVD
added 2025/06/24 12:15 p.m.6 views

CVE-2025-39201

A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service...

6.9CVSS0.00121EPSS
Exploits0References1
OSV
OSV
added 2025/06/24 12:15 p.m.7 views

CVE-2025-39203

A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop...

7.1CVSS5.8AI score0.00202EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/06/24 12:13 p.m.11 views

CVE-2025-39205

A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation...

7.1CVSS0.00177EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/06/24 12:13 p.m.6 views

CVE-2025-39205

A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation...

7.1CVSS7.2AI score0.00177EPSS
Exploits0References1
CVE
CVE
added 2025/06/24 12:13 p.m.24 views

CVE-2025-39205

CVE-2025-39205 affects Hitachi Energy MicroSCADA X SYS600 (IEC 61850). The TLS certificate validation is insufficient, enabling a remote Man-in-the-Middle attack due to improper certificate validation. Public sources (NVD, Red Hat, CISA ICS advisories, CPSIR-style entries) corroborate an TLS vali...

7.1CVSS7.2AI score0.00177EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2025/06/24 12:1 p.m.12 views

CVE-2025-39204

A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user...

8.5CVSS0.00318EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/06/24 12:1 p.m.7 views

CVE-2025-39204

A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user...

8.5CVSS6.7AI score0.00318EPSS
Exploits0References1
CVE
CVE
added 2025/06/24 12:1 p.m.25 views

CVE-2025-39204

The CVE-2025-39204 entry affects Hitachi MicroSCADA X SYS600, specifically a vulnerability in the Web interface where a malformed filtering query can leak file content via the Web UI. Affected component: the Web interface filtering logic; root cause: malformed queries exposing data. Impact: infor...

8.5CVSS6.7AI score0.00318EPSS
Exploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2025/06/24 11:57 a.m.4 views

CVE-2025-39203

A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop...

7.1CVSS7.2AI score0.00202EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/06/24 11:57 a.m.13 views

CVE-2025-39203

A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop...

7.1CVSS0.00202EPSS
Exploits0References1
CVE
CVE
added 2025/06/24 11:57 a.m.33 views

CVE-2025-39203

The CVE-2025-39203 entry concerns the IEC 61850 component of Hitachi Energy’s MicroSCADA X SYS600. The connected documents provide concrete details: a crafted IEC 61850-8 message from an IED or remote system can cause a denial of service, resulting in a disconnection loop in SYS600. The issue is ...

7.1CVSS7.2AI score0.00202EPSS
Exploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2025/06/24 11:51 a.m.5 views

CVE-2025-39202

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption...

8.3CVSS6.7AI score0.00211EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/06/24 11:51 a.m.19 views

CVE-2025-39202

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption...

8.3CVSS0.00211EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/06/24 11:46 a.m.12 views

CVE-2025-39201

A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service...

6.9CVSS0.00121EPSS
Exploits0References1
CVE
CVE
added 2025/06/24 11:46 a.m.22 views

CVE-2025-39201

CVE-2025-39201 refers to vulnerabilities in Hitachi Energy’s MicroSCADA X SYS600 affecting multiple subsystems (mailslot, monitors/logs, TLS certificate validation, and crafted IEC 61850 messages). Public sources (ICS advisories) indicate: a local access requirement can allow a local attacker to ...

6.9CVSS6.9AI score0.00121EPSS
Exploits0References1Affected Software1
CNNVD
CNNVD
added 2025/06/24 12:0 a.m.8 views

Hitachi MicroSCADA X SYS600 安全漏洞

Hitachi MicroSCADA X SYS600 is a Hitachi MicroSCADA X SYS600 data acquisition and monitoring control system mainly used in power systems. A security vulnerability exists in the Hitachi MicroSCADA X SYS600 that originates from insufficient validation of Monitor Pro interface privileges resulting i...

8.3CVSS6.1AI score0.00211EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2025/06/24 12:0 a.m.8 views

PT-2025-26720

Name of the Vulnerable Software and Affected Versions: MicroSCADA X SYS600 affected versions not specified Description: A vulnerability exists in the IEC 61850 protocol implementation, allowing a remote Man-in-the-Middle attack due to missing proper validation of the TLS protocol's certificate...

7.1CVSS5.9AI score0.00177EPSS
Exploits0References7
CNNVD
CNNVD
added 2025/06/24 12:0 a.m.6 views

Hitachi MicroSCADA X SYS600 安全漏洞

Hitachi MicroSCADA X SYS600 is a data acquisition and monitoring control system primarily used in power systems from Hitachi, Japan. A security vulnerability exists in the HITACHI MicroSCADA X SYS600 that stems from an insufficient validation of the TLS protocol certificate leading to a...

7.1CVSS6.4AI score0.00177EPSS
Exploits0References2
Rows per page
Query Builder