103 matches found
Mia Technology MIA-MED Encryption Issue Vulnerability
Mia Technology MIA-MED is a hospital management system from Mia Technology. A cryptographic issue vulnerability exists in Mia Technology MIA-MED versions prior to 1.0.14 that stems from the presence of a corrupt or dangerous cryptographic algorithm that allows signature spoofing via improper...
PT-2024-37201
Name of the Vulnerable Software and Affected Versions: Mia-Med Health Aplication versions prior to 1.0.14 Description: The issue is related to an Improper Restriction of Excessive Authentication Attempts, allowing Interface Manipulation in the Mia-Med Health Aplication. Recommendations: For...
Mia Technology MIA-MED Security Vulnerability
Mia Technology MIA-MED is a hospital management system from Mia Technology. A security vulnerability exists in Mia Technology MIA-MED versions prior to 1.0.14 that stems from an improper restriction of excessive authentication attempts...
CVE-2024-5862: Improper Restriction of Excessive Authentication Attempts
Improper Restriction of Excessive Authentication Attempts vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Interface Manipulation. This issue affects Mia-Med Health Aplication: before 1.0.14...
CVE-2024-3264: Use of a Broken or Risky Cryptographic Algorithm
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation. This issue affects Mia-Med Health Aplication: before 1.0.14...
CVE-2023-6519
Exposure of Data Element to Wrong Session vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable.This issue affects MİA-MED: before 1.0.7...
CVE-2023-6517
Exposure of Sensitive Information Due to Incompatible Policies vulnerability in Mia Technology Inc. MİA-MED allows Collect Data as Provided by Users. This issue affects MİA-MED: before 1.0.7...
CVE-2023-6519
Exposure of Data Element to Wrong Session vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable. This issue affects MİA-MED: before 1.0.7...
CVE-2023-6518
Plaintext Storage of a Password vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable. This issue affects MİA-MED: before 1.0.7...
CVE-2023-6517
Exposure of Sensitive Information Due to Incompatible Policies vulnerability in Mia Technology Inc. MİA-MED allows Collect Data as Provided by Users.This issue affects MİA-MED: before 1.0.7...
CVE-2023-6519
Exposure of Data Element to Wrong Session vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable. This issue affects MİA-MED: before 1.0.7...
CVE-2023-6518
Plaintext Storage of a Password vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable.This issue affects MİA-MED: before 1.0.7...
CVE-2023-6517
Exposure of Sensitive Information Due to Incompatible Policies vulnerability in Mia Technology Inc. MİA-MED allows Collect Data as Provided by Users. This issue affects MİA-MED: before 1.0.7...
Design/Logic Flaw
Exposure of Data Element to Wrong Session vulnerability in Mia Technology Inc. MIA-MED allows Read Sensitive Strings Within an Executable.This issue affects MIA-MED: before 1.0.7...
Spoofing
Plaintext Storage of a Password vulnerability in Mia Technology Inc. MIA-MED allows Read Sensitive Strings Within an Executable.This issue affects MIA-MED: before 1.0.7...
Design/Logic Flaw
Exposure of Sensitive Information Due to Incompatible Policies vulnerability in Mia Technology Inc. MIA-MED allows Collect Data as Provided by Users.This issue affects MIA-MED: before 1.0.7...
CVE-2023-6519 Seeing admin password hash value in Mia Technology's Mia-Med
Exposure of Data Element to Wrong Session vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable. This issue affects MİA-MED: before 1.0.7...
CVE-2023-6519 Seeing admin password hash value in Mia Technology's Mia-Med
Exposure of Data Element to Wrong Session vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable. This issue affects MİA-MED: before 1.0.7...
CVE-2023-6519
CVE-2023-6519 affects Mia Technology Inc.'s MIA-MED prior to version 1.0.7. The issue is described as Exposure of Data Element to Wrong Session, enabling reading of sensitive strings within an executable. Affects MIA-MED before 1.0.7; CVSS 3.1 base score 7.5 (High), network attack vector, no user...
CVE-2023-6518
CVE-2023-6518 : A plaintext password storage flaw in Mia Technology Inc.’s MIA-MED prior to 1.0.7 allows reading sensitive strings from the executable, compromising confidentiality. Affected product: MIA-MED (pre-1.0.7). Root cause: plaintext password storage. Impact: high confidentiality risk; n...