Lucene search
+L

6 matches found

Mageia
Mageia
•added 2024/10/04 5:27 a.m.•54 views

Updated hostapd & wpa_supplicant packages fix security vulnerability

The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...

7.4CVSS7.2AI score0.00716EPSS
SaveExploits0References2
OSV
OSV
•added 2024/05/17 9:15 p.m.•37 views

CVE-2023-52424

The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...

6.7AI score0.00716EPSS
SaveExploits0References6Affected Software1
UbuntuCve
UbuntuCve
•added 2024/05/17 9:15 p.m.•53 views

CVE-2023-52424

The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...

7.4CVSS6.6AI score0.00716EPSS
SaveExploits0References5
CVE
CVE
•added 2024/05/17 8:28 p.m.•137 views

CVE-2023-52424

The IEEE 802.11 standard is vulnerable to an SSID Confusion issue, which can trick victims into connecting to unintended or untrusted networks. This flaw exists because the SSID is not always used to derive the pairwise master key or session keys , and there is no protected exchange of an SSID du...

7.4CVSS6.7AI score0.00716EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2024/05/17 8:28 p.m.•24 views

CVE-2023-52424

The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...

6.8AI score0.00716EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/05/17 12:00 a.m.•3 views

CVE-2023-52424: Missing Critical Step in Authentication

The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...

7.4CVSS5.8AI score0.00716EPSS
SaveExploits0References1
Rows per page
Query Builder