2148 matches found
Trend Micro Apex One 安全漏洞
Trend Micro Apex One is an endpoint protection software from Trend Micro. A security vulnerability exists in Trend Micro Apex One, which stems from the fact that the monitoring engine component of its Apex One service is compiled without using the /SAFESEH memory protection mechanism...
MediaTek 芯片 缓冲区错误漏洞
MediaTek chips are a variety of chips from MediaTek, a Chinese company. A security vulnerability exists in the MediaTek chips, which stems from a logic error found in the mpu that could lead to memory corruption...
CVE-2022-44654
Affected builds of Trend Micro Apex One and Apex One as a Service contain a monitor engine component that is complied without the /SAFESEH memory protection mechanism which helps to monitor for malicious payloads. The affected component's memory protection mechanism has been updated to enhance...
CVE-2022-44654
Affected builds of Trend Micro Apex One and Apex One as a Service contain a monitor engine component that is complied without the /SAFESEH memory protection mechanism which helps to monitor for malicious payloads. The affected component's memory protection mechanism has been updated to enhance...
PT-2022-27283 · Trend Micro · Trend Micro Apex One +1
Name of the Vulnerable Software and Affected Versions: Trend Micro Apex One and Apex One as a Service affected versions not specified Description: The issue concerns a monitor engine component in Trend Micro Apex One and Apex One as a Service that was compiled without the /SAFESEH memory protecti...
PT-2022-19517 · Intel · Fwblockservicesmm
Name of the Vulnerable Software and Affected Versions: FwBlockServiceSmm driver versions prior to 05.21.51.0048 FwBlockServiceSmm driver versions prior to 05.42.23.0066 FwBlockServiceSmm driver versions prior to 05.42.11.0021 FwBlockServiceSmm driver versions prior to 05.44.25.0052...
GSD-2022-1007546 usb: mon: make mmapped memory read only
usb: mon: make mmapped memory read only This is an automated ID intended to aid in discovery of potential security vulnerabilities. The actual impact and attack plausibility have not yet been proven. This ID is fixed in Linux Kernel version v4.19.262 by commit...
CVE-2022-32831
CVE-2022-32831 is an out-of-bounds read issue fixed by improved bounds checking in Apple code. Affected were macOS versions prior to Security Update 2022-005 and macOS Big Sur 11.6.8, Monterey 12.5, and Catalina. Processing a maliciously crafted AppleScript binary may lead to unexpected terminati...
CVE-2022-38406
Adobe InCopy version 17.3 and earlier and 16.4.2 and earlier are affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to bypass mitigations such as ASLR. Exploitation of this issue requires user interactio...
CVE-2022-34262
Adobe Illustrator versions 26.3.1 and earlier and 25.4.6 and earlier are affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to bypass mitigations such as ASLR. Exploitation of this issue requires user...
CVE-2022-20239
remappfnrange' here may map out of size kernel memory for example, may map the kernel area, and because the 'vma-vmpageprot' can also be controlled by userspace, so userspace may map the kernel area to be writable, which is easy to be exploitedProduct: AndroidVersions: Android SoCAndroid ID:...
ASB-A-233972091
'remappfnrange' here may map out of size kernel memory for example, may map the kernel area, and because the 'vma-vmpageprot' can also be controlled by userspace, so userspace may map the kernel area to be writable, which is easy to be exploited...
CVE-2022-30315
Honeywell Experion PKS Safety Manager SM and FSC through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell...
CVE-2022-30315
Honeywell Experion PKS Safety Manager SM and FSC through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell...
CVE-2022-31206
The Omron SYSMAC Nx product family PLCs NJ series, NY series, NX series, and PMAC series through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software which compiles IEC 61131-3 conformant POU code to native machine code for execution...
CVE-2022-29958
JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory...
CVE-2022-29958
JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory...
Design/Logic Flaw
The Omron SYSMAC Nx product family PLCs NJ series, NY series, NX series, and PMAC series through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software which compiles IEC 61131-3 conformant POU code to native machine code for execution...
CVE-2022-31206
The Omron SYSMAC Nx product family PLCs NJ series, NY series, NX series, and PMAC series through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software which compiles IEC 61131-3 conformant POU code to native machine code for execution...
CVE-2022-29958
CVE-2022-29958 affects JTEKT TOYOPUC PLCs up to 2022-04-29, where control logic and projects can be downloaded via unauthenticated CMPLink/TCP without cryptographic authentication. The downloaded code is block-based and executed in the PLC runtime without memory protection, on CPU modules (e.g., ...