Lucene search
+L

694 matches found

NVD
NVD
added 2020/11/02 9:15 p.m.27 views

CVE-2020-5653

Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 Hi...

9.8CVSS9.6AI score0.03209EPSS
SaveExploits0References3
NVD
NVD
added 2020/11/02 9:15 p.m.28 views

CVE-2020-5655

NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...

7.5CVSS8AI score0.02945EPSS
SaveExploits0References3
Prion
Prion
added 2020/11/02 9:15 p.m.19 views

Buffer overflow

Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 Hi...

7.5CVSS9.5AI score0.03209EPSS
SaveExploits0References3
Prion
Prion
added 2020/11/02 9:15 p.m.17 views

Race condition

Uncontrolled resource consumption vulnerability in Ethernet Port on MELSEC iQ-R, Q and L series CPU modules R 00/01/02 CPU firmware versions '20' and earlier, R 04/08/16/32/120 EN CPU firmware versions '52' and earlier, R 08/16/32/120 SFCPU firmware versions '22' and earlier, R 08/16/32/120 PCPU...

5CVSS7.4AI score0.03572EPSS
SaveExploits0References3Affected Software29
Prion
Prion
added 2020/11/02 9:15 p.m.21 views

Design/Logic Flaw

Improper neutralization of argument delimiters in a command 'Argument Injection' vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Modul...

3.3CVSS7.2AI score0.01063EPSS
SaveExploits0References3
Prion
Prion
added 2020/11/02 9:15 p.m.23 views

Session fixation

Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96...

5CVSS7.9AI score0.02736EPSS
SaveExploits0References3
Prion
Prion
added 2020/11/02 9:15 p.m.24 views

Improper access control

Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...

7.5CVSS9.4AI score0.02969EPSS
SaveExploits0References3
Prion
Prion
added 2020/11/02 9:15 p.m.23 views

Design/Logic Flaw

Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...

5CVSS7.9AI score0.0292EPSS
SaveExploits0References3
Prion
Prion
added 2020/11/02 9:15 p.m.21 views

Null pointer dereference

NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...

5CVSS7.9AI score0.02945EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2020/10/30 3:35 a.m.31 views

CVE-2020-5658

Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...

7.5AI score0.0292EPSS
SaveExploits0References3
CVE
CVE
added 2020/10/30 3:35 a.m.57 views

CVE-2020-5658

The CVE-2020-5658 entry concerns a Resource Management Errors vulnerability in the TCP/IP functionality of MELSEC iQ-R series firmware. Affected modules and serial-number guards: EtherNet/IP Network Interface Module RJ71EIP91 (first two digits of serial ≤ 02), PROFINET IO Controller RJ71PN92 (≤ 0...

7.5CVSS7.5AI score0.0292EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2020/10/30 3:35 a.m.57 views

CVE-2020-5657

The CVE-2020-5657 issue affects MELSEC iQ-R firmware and is caused by improper neutralization of argument delimiters in a TCP/IP function. A crafted packet from an adjacent network could cause a denial-of-service condition or stop network functions on affected modules: RJ71EIP91 (EtherNet/IP), RJ...

6.5CVSS6.6AI score0.01063EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2020/10/30 3:35 a.m.31 views

CVE-2020-5657

Improper neutralization of argument delimiters in a command 'Argument Injection' vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Modul...

6.6AI score0.01063EPSS
SaveExploits0References3
CVE
CVE
added 2020/10/30 3:35 a.m.59 views

CVE-2020-5656

CVE-2020-5656 affects Mitsubishi Electric MELSEC iQ-R Series firmware: EtherNet/IP/PROFINET interface modules RJ71EIP91, RJ71PN92, and data/OPC modules RD81DL96, RD81MES96N, RD81OPC96. Root cause: improper access control in the TCP/IP function, enabling a remote unauthenticated attacker to stop n...

9.8CVSS9.3AI score0.02969EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2020/10/30 3:35 a.m.61 views

CVE-2020-5655

CVE-2020-5655 is a NULL pointer dereference vulnerability in the TCP/IP code of MELSEC iQ‑R firmware. A remote, unauthenticated attacker can stop network functions by sending a specially crafted packet. Affected modules and serial-number constraints from connected sources: EtherNet/IP Network Int...

7.5CVSS7.5AI score0.02945EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2020/10/30 3:35 a.m.25 views

CVE-2020-5656

Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...

9.5AI score0.02969EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2020/10/30 3:35 a.m.37 views

CVE-2020-5655

NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...

7.5AI score0.02945EPSS
SaveExploits0References3
CVE
CVE
added 2020/10/30 3:35 a.m.58 views

CVE-2020-5654

CVE-2020-5654 is a session-fixation vulnerability in the TCP/IP function of MELSEC iQ-R series firmware. A remote, unauthenticated attacker can stop the network functions of affected modules by sending a specially crafted packet. Affected MELSEC iQ-R components include EtherNet/IP Network Interfa...

7.5CVSS7.5AI score0.02736EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2020/10/30 3:35 a.m.29 views

CVE-2020-5653

Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 Hi...

9.6AI score0.03209EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2020/10/30 3:35 a.m.30 views

CVE-2020-5654

Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96...

7.5AI score0.02736EPSS
SaveExploits0References3
Rows per page