Lucene search
+L

42 matches found

VulnCheck KEV
VulnCheck KEV
added 2021/11/15 12:0 a.m.6 views

VulnCheck KEV: CVE-2021-24946

The Modern Events Calendar Lite WordPress plugin before 6.1.5 does not sanitise and escape the time parameter before using it in a SQL statement in the mecloadsinglepage AJAX action, available to unauthenticated users, leading to an unauthenticated SQL injection issue...

9.8CVSS7.4AI score0.728EPSS
SaveExploits7References1
OSV
OSV
added 2021/11/09 12:15 p.m.7 views

CVE-2021-31888

A vulnerability has been identified in APOGEE MBC PPC BACnet All versions, APOGEE MBC PPC P2 Ethernet All versions, APOGEE MEC PPC BACnet All versions, APOGEE MEC PPC P2 Ethernet All versions, APOGEE PXC Compact BACnet All versions = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and...

8.8CVSS7.8AI score0.02371EPSS
SaveExploits0References2
NVD
NVD
added 2021/11/09 12:15 p.m.44 views

CVE-2021-31882

A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303. The DHCP client application does not validate the length of the Domain Name Server IP options 0x06 when processing DHCP ACK packets. This may lead to...

7.5CVSS0.01476EPSS
SaveExploits0References6
NVD
NVD
added 2021/11/09 12:15 p.m.33 views

CVE-2021-31890

A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, PLUSCONTROL 1st Gen All versions, SIMOTICS CONNECT 400 All versions V0.5.0.0, SIMOTICS CONNECT 400 All versions V1.0.0.0. The total length of an TCP...

9.1CVSS0.0215EPSS
SaveExploits0References10
Prion
Prion
added 2021/11/09 12:15 p.m.31 views

Design/Logic Flaw

A vulnerability has been identified in APOGEE MBC PPC BACnet All versions, APOGEE MBC PPC P2 Ethernet All versions, APOGEE MEC PPC BACnet All versions, APOGEE MEC PPC P2 Ethernet All versions, APOGEE PXC Compact BACnet All versions = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and...

7.5CVSS9.2AI score0.01451EPSS
SaveExploits0References3Affected Software18
Cvelist
Cvelist
added 2021/11/09 11:32 a.m.44 views

CVE-2021-31888

A vulnerability has been identified in APOGEE MBC PPC BACnet All versions, APOGEE MBC PPC P2 Ethernet All versions, APOGEE MEC PPC BACnet All versions, APOGEE MEC PPC P2 Ethernet All versions, APOGEE PXC Compact BACnet All versions = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and...

9.5AI score0.02371EPSS
SaveExploits0References2
CVE
CVE
added 2021/11/09 11:31 a.m.97 views

CVE-2021-31885

CVE-2021-31885 : TFTP memory buffer reading vulnerability reported in Siemens Nucleus APOGEE/MBC/TALON/TALON-related products (PPC/BACnet, P2 Ethernet, Desigo PXC, PXM, Nucleus NET, etc.) where a malformed TFTP command can read the contents of the TFTP memory buffer. Source documents from the vul...

7.5CVSS8.4AI score0.01197EPSS
SaveExploits0References3Affected Software5
CVE
CVE
added 2021/11/09 11:31 a.m.107 views

CVE-2021-31884

CVE-2021-31884 affects Siemens Nucleus/APOGEE/TALON family (MBC/MEC/PXC/Nucleus) with a DHCP client hostname option handling flaw. The DHCP hostname data is not guaranteed to be NULL-terminated, which can cause out-of-bounds reads/writes and Denial-of-Service. The available connected sources conf...

9.8CVSS9.1AI score0.01451EPSS
SaveExploits0References3Affected Software4
CVE
CVE
added 2021/11/09 11:31 a.m.121 views

CVE-2021-31883

CVE-2021-31883 affects Siemens APOGEE MBC / TALON products (Nucleus RTOS) including APOGEE MBC (PPC/BACnet), APOGEE MEC, APOGEE PXC Compact/Modular, Desigo PXC variants, and Capital VSTAR with Ethernet options. Root cause: DHCP client processing fails to validate the length of Vendor option(s) in...

7.5CVSS7.9AI score0.01477EPSS
SaveExploits0References6Affected Software4
Cvelist
Cvelist
added 2021/11/09 11:31 a.m.39 views

CVE-2021-31883

A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303. When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor options, leading to Denial-of-Service...

7.1CVSS8.7AI score0.01477EPSS
SaveExploits0References6
CVE
CVE
added 2021/11/09 11:31 a.m.104 views

CVE-2021-31881

CVE-2021-31881 involves APOGEE MBC/TALON/Desigo PXC software family (Siemens Nucleus RTOS, BACnet/PPC) where the DHCP client fails to validate the Vendor option length when processing DHCP OFFER, leading to Denial-of-Service. Multiple Tenable OT/Nessus entries corroborate this family of DHCP leng...

7.5CVSS7.9AI score0.01477EPSS
SaveExploits0References6Affected Software4
CVE
CVE
added 2021/11/09 11:31 a.m.171 views

CVE-2021-31345

CVE-2021-31345 affects Siemens Nucleus NET-based products (Capital Embedded AR Classic, CAPITAL VSTAR/PLUSCONTROL) with an unchecked UDP payload length in the IP header. Root cause: UDP payload length is not validated, enabling information leaks and potential denial-of-service depending on the us...

9.1CVSS8.2AI score0.01578EPSS
SaveExploits0References8Affected Software4
CVE
CVE
added 2021/11/09 11:31 a.m.115 views

CVE-2021-31344

CVE-2021-31344 affects Siemens/Nucleus-based devices such as Capital Embedded AR Classic, PLUSCONTROL 1st Gen, and SIMOTICS CONNECT 400 (all versions with certain UDP/ICMP handling). The vulnerability is triggered by ICMP echo packets with fake IP options, enabling ICMP echo replies to arbitrary ...

6.9CVSS7AI score0.01409EPSS
SaveExploits0References10Affected Software5
Positive Technologies
Positive Technologies
added 2021/11/09 12:0 a.m.15 views

PT-2021-6896 · Unknown +1 · Nucleus Source Code +10

Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions prior to V2303 PLUSCONTROL 1st Gen versions all APOGEE MBC versions all APOGEE MEC versions all APOGEE PXC versions all TALON TC versions all Nucleus...

9.4CVSS6.7AI score0.01578EPSS
SaveExploits0References11
Positive Technologies
Positive Technologies
added 2021/11/09 12:0 a.m.33 views

PT-2021-6242 · Mentor Graphics +1 · Nucleus Net +11

Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions prior to V2303 PLUSCONTROL 1st Gen versions all SIMOTICS CONNECT 400 versions prior to V0.5.0.0 APOGEE MBC versions all APOGEE MEC versions all APOGE...

9.4CVSS6.7AI score0.02106EPSS
SaveExploits0References13
Positive Technologies
Positive Technologies
added 2021/11/09 12:0 a.m.13 views

PT-2021-19251 · Siemens +1 · Simotics Connect 400 +12

Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions all prior to V2303 PLUSCONTROL 1st Gen versions all SIMOTICS CONNECT 400 versions all prior to V0.5.0.0 SIMOTICS CONNECT 400 versions all prior to...

6.9CVSS6.8AI score0.01409EPSS
SaveExploits0References12
Positive Technologies
Positive Technologies
added 2021/11/09 12:0 a.m.13 views

PT-2021-19564 · Unknown · Nucleus Readystart V3 +9

Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions prior to V2303 Capital Embedded AR Classic R20-11 versions prior to V2303 APOGEE MBC PPC BACnet all versions APOGEE MBC PPC P2 Ethernet all versions APOGEE MEC PPC BACnet all versions APOGEE MEC PP...

7.5CVSS7AI score0.01477EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
added 2021/11/09 12:0 a.m.11 views

PT-2021-6895 · Mentor Graphics +1 · Nucleus Net +9

Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions prior to V2303 Capital Embedded AR Classic R20-11 versions prior to V2303 PLUSCONTROL 1st Gen versions prior to the fixed version SIMOTICS CONNECT 400 versions prior to V0.5.0.0 SIMOTICS CONNECT 40...

9.4CVSS7.1AI score0.01902EPSS
SaveExploits0References13
NVD
NVD
added 2021/09/14 11:15 a.m.48 views

CVE-2021-27391

A vulnerability has been identified in APOGEE MBC PPC P2 Ethernet All versions = V2.6.3, APOGEE MEC PPC P2 Ethernet All versions = V2.6.3, APOGEE PXC Compact BACnet All versions = V2.8, APOGEE PXC Modular BACnet All versions = V2.8, TALON TC Compact BACnet All versions V3.5.3, TALON TC Modular...

10CVSS0.03369EPSS
SaveExploits0References1
CVE
CVE
added 2021/09/14 10:47 a.m.89 views

CVE-2021-27391

Summary: CVE-2021-27391 affects Siemens APOGEE and TALON devices. The vulnerability is a buffer overflow in the web server caused by improper bounds checking when parsing the Host header in HTTP requests. The issue affects multiple products/versions: APOGEE MBC (PPC) and APOGEE MEC (PPC) with ver...

10CVSS9.7AI score0.03369EPSS
SaveExploits0References1Affected Software1
Rows per page