Lucene search
K

12 matches found

Vulnrichment
Vulnrichment
added 2025/10/20 12:0 a.m.2 views

CVE-2024-55568

An issue was discovered in Samsung Mobile Processor, Wearable Processor, and Modem Exynos 980, 990, 850, 1080, 2100, 1280, 2200, 1330, 1380, 1480, 2400, 9110, W920, W930, W1000, Modem 5123, Modem 5300, Modem 5400. The absence of a NULL check leads to a Denial of Service when an attacker sends...

6.5AI score0.00113EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2025/08/27 12:0 a.m.4 views

Linux Distros Unpatched Vulnerability : CVE-2021-34145

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - The Bluetooth Classic implementation in the Cypress WICED BT stack through 2.9.0 for CYW20735B1 devices does not properly handle the reception of LMPmaxslot wit...

5.3CVSS5.7AI score0.00116EPSS
Exploits0References2
OSV
OSV
added 2024/11/13 5:15 a.m.1 views

CVE-2024-9409

CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network...

7.5CVSS5.8AI score
Exploits0References1
Positive Technologies
Positive Technologies
added 2024/07/10 12:0 a.m.1 views

PT-2024-8671 · Juniper Networks · Junos Evolved +1

Name of the Vulnerable Software and Affected Versions: Junos OS versions prior to 21.2R3-S4 Junos OS versions 21.4 prior to 21.4R2 Junos OS versions 22.2 prior to 22.2R3-S2 Junos OS Evolved versions prior to 21.2R3-S8-EVO Junos OS Evolved versions 21.4 prior to 21.4R2-EVO Description: An Improper...

8.7CVSS7.2AI score0.00324EPSS
Exploits0References8
CNNVD
CNNVD
added 2022/01/04 12:0 a.m.2 views

MediaTek 芯片 安全漏洞

MediaTek chips are a variety of chips from MediaTek, a division of China's MediaTek Mediatek. A security vulnerability exists in the MediaTek chips, which stems from Bluetooth flooding the device with LMPAUrand packets, potentially crashing the application...

6.5CVSS6.5AI score0.00136EPSS
Exploits0References2
OSV
OSV
added 2019/03/28 12:29 a.m.1 views

CVE-2019-1746

A vulnerability in the Cluster Management Protocol CMP processing code in Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, adjacent attacker to trigger a denial of service DoS condition on an affected device. The vulnerability is due to insufficient input validation wh...

6.5CVSS6.9AI score
Exploits0References2
CNVD
CNVD
added 2019/03/28 12:0 a.m.1 views

Cisco IOS and IOS XE CMP Denial of Service Vulnerability

Cisco IOS and IOS XE are a set of operating systems developed by Cisco for its network devices. An input validation vulnerability exists in the Cluster Management Protocol CMP handling code in Cisco IOS and IOS XE. An attacker could exploit this vulnerability by sending malicious CMP management...

7.4CVSS6.9AI score0.00145EPSS
Exploits0References1
CNVD
CNVD
added 2016/08/19 12:0 a.m.3 views

Cisco Adaptive Security Appliance Software Remote Code Execution Vulnerability

The Cisco ASA 5500 Series Adaptive Security Appliances are modular platforms for delivering security and VPN services, providing firewall, IPS, anti-X, and VPN services. A remote code execution vulnerability exists in the SNMP code of the Cisco Adaptive Security Appliance ASA Software. A remote...

8.8CVSS8.4AI score0.90783EPSS
Exploits7References1
NVD
NVD
added 2006/12/23 11:28 a.m.12 views

CVE-2006-6717

The Allied Telesis AT-9000/24 Ethernet switch accepts management packets from arbitrary VLANs, contrary to the documentation, which allows remote attackers to conduct attacks against the switch from unexpected locations...

7.5CVSS6.8AI score0.00911EPSS
Exploits0References5
Cvelist
Cvelist
added 2006/12/23 11:0 a.m.18 views

CVE-2006-6717

The Allied Telesis AT-9000/24 Ethernet switch accepts management packets from arbitrary VLANs, contrary to the documentation, which allows remote attackers to conduct attacks against the switch from unexpected locations...

6.8AI score0.00911EPSS
Exploits0References5
securityvulns
securityvulns
added 2006/11/14 12:0 a.m.43 views

3Com SuperStack 3 switch SNMP information leak

It's possible to get SNMP community string with management packets...

3.8AI score
Exploits0References1Affected Software1
NVD
NVD
added 2006/10/25 11:7 p.m.8 views

CVE-2006-5382

3Com Switch SS3 4400 switches, firmware 5.11, 6.00 and 6.10 and earlier, allow remote attackers to read the SNMP Read-Write Community string and conduct unauthorized actions via unspecified "normally restricted management packets on the device" that cause the community string to be returned...

7.5CVSS6.7AI score0.012EPSS
Exploits0References6
Rows per page
Query Builder