Lucene search
+L

7 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•15 views

EUVD-2020-28614

Malware in sbrugna...

9.8CVSS9.2AI score0.01596EPSS
SaveExploits0References2
NVD
NVD
•added 2021/10/12 3:15 p.m.•46 views

CVE-2021-38178

The software logistics system of SAP NetWeaver AS ABAP and ABAP Platform versions - 700, 701, 702, 710, 730, 731, 740, 750, 751, 752, 753, 754, 755, 756, enables a malicious user to transfer ABAP code artifacts or content, by-passing the established quality gates. By this vulnerability malicious...

8.8CVSS0.01294EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/10/12 12:00 a.m.•2 views

CVE-2021-38178: Undefined Security Weakness

The software logistics system of SAP NetWeaver AS ABAP and ABAP Platform versions - 700, 701, 702, 710, 730, 731, 740, 750, 751, 752, 753, 754, 755, 756, enables a malicious user to transfer ABAP code artifacts or content, by-passing the established quality gates. By this vulnerability malicious...

8.8CVSS6.1AI score0.01294EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2020/04/22 6:15 p.m.•10 views

CVE-2020-7489

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software versions in security notification. The result of this vulnerability, DLL substitution, coul...

7.4AI score0.01596EPSS
SaveExploits0References1
OSV
OSV
•added 2020/03/23 7:15 p.m.•7 views

CVE-2020-7475

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...

9.8CVSS7.4AI score
SaveExploits0References1
Cvelist
Cvelist
•added 2020/03/23 6:56 p.m.•53 views

CVE-2020-7475

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...

9.5AI score0.01581EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/03/23 12:00 a.m.•2 views

CVE-2020-7475: Improper Neutralization of Special Elements in Output Used by a Downstream Component

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...

9.8CVSS8.1AI score0.01581EPSS
SaveExploits0References3
Rows per page
Query Builder