Lucene search
K

8 matches found

BDU FSTEC
BDU FSTEC
added 2024/07/05 12:0 a.m.0 views

The vulnerability of SIMATIC PCS, SIMATIC WinCC Runtime Professional, and SIMATIC WinCC control systems lies in the copying of buffers without checking the size of the input data. This allows a malicious actor to trigger malfunctions during maintenance operations.

The vulnerability of SIMATIC PCS, SIMATIC WinCC Runtime Professional, and SIMATIC WinCC control systems lies in the copying of buffers without checking the size of the input data. Exploiting this vulnerability can allow attackers to cause malfunctions in the system’s operations...

6.2CVSS7.2AI score0.00051EPSS
Exploits0References2Affected Software2
BDU FSTEC
BDU FSTEC
added 2022/08/12 12:0 a.m.0 views

Vulnerabilities of microprogramming software for Siemens STEP 7 programmable logic controllers, systems for manufacturing process control such as Opcenter Execution Discrete, Opcenter Execution Process, Opcenter Execution Foundation, Opcenter Intelligence, Opcenter Quality, SIMATIC IT Production Suite, the system diagnostic tool SIMOCODE ES, the software for parameterizing, diagnosing, and documenting device startup data (SIRIUS Soft Starter ES), technological process control systems like SIMATIC PCS neo, the Opcenter RD&L software platform, and the software for analyzing equipment efficiency and key indicators SIMATIC IT LMS. These vulnerabilities may allow a intruder to trigger malfunctions during maintenance operations due to improper cleaning or resource release.

The vulnerabilities of the microprogramming software for Siemens STEP 7 programmable logic controllers, the systems for managing production processes such as Opcenter Execution Discrete, Opcenter Execution Process, Opcenter Execution Foundation, Opcenter Intelligence, Opcenter Quality, SIMATIC IT...

6.5CVSS0.00498EPSS
Exploits0References2Affected Software7
BDU FSTEC
BDU FSTEC
added 2022/06/01 12:0 a.m.0 views

The vulnerability of the CPU FX5U(C) and FX5UJ modules of MELSEC iQ-F series PLCs, which stems from insufficient input data verification, allows attackers to trigger malfunctions during maintenance operations.

The vulnerability of the CPU FX5UC and FX5UJ modules of the MELSEC iQ-F series is related to insufficient checking of input data. Exploiting this vulnerability can allow an attacker to cause malfunctions in the system...

8.6CVSS0.0032EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2021/06/23 12:0 a.m.2 views

The vulnerability of the microprogrammed software of WAGO Series PFC200 programmable logic controllers, related to unlimited resource distribution, allows a intruder to cause malfunctions during maintenance.

The vulnerability of the microprogrammed software in WAGO Series PFC200 programmable logic controllers is related to the unlimited distribution of resources. Exploiting this vulnerability could allow a remote operator to cause a malfunction in the service operation...

7.8CVSS0.00161EPSS
Exploits0References3Affected Software13
BDU FSTEC
BDU FSTEC
added 2019/04/23 12:0 a.m.1 views

The vulnerability of microprogrammed software in programmable logic controllers from SIMATIC, related to insufficient validation of input data, allows a malicious actor to trigger malfunctions during maintenance operations.

The vulnerability of microprogrammed software in programmable logic controllers from SIMATIC is related to insufficient verification of input data. Exploiting this vulnerability can allow a malicious individual to cause malfunctions in service operations by sending specially crafted packets to po...

7.8CVSS7.2AI score0.05261EPSS
Exploits0References3Affected Software21
BDU FSTEC
BDU FSTEC
added 2017/01/26 12:0 a.m.2 views

Multiple vulnerabilities exist in the embedded programmable logic controller OVEEN PLK110 software, allowing a malicious actor to cause malfunctions during maintenance operations.

Multiple vulnerabilities exist in the embedded programmable logic controller OVEEN PLK110’s software, due to insufficient testing of input data. Exploitation of these vulnerabilities could allow an attacker to trigger malfunctions by repeatedly sending specially crafted requests with randomly...

3.5CVSS5.5AI score
Exploits0Affected Software1
BDU FSTEC
BDU FSTEC
added 2016/07/07 12:0 a.m.1 views

The vulnerability of the microprogramming software of Siemens Simatic S7-1200 programmable logic controllers allows a malicious actor to cause malfunctions during maintenance operations.

The software of the Siemens SIMATIC S7-1200 programmable logic controller contains a vulnerability. When this vulnerability is exploited, a special SNMP packet can be sent to trigger a “failure to service” condition for the device...

7.8CVSS5.5AI score0.00342EPSS
Exploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2016/07/07 12:0 a.m.2 views

The vulnerability of the microprogramming software of Siemens Simatic S7-1200 programmable logic controllers allows a malicious actor to cause malfunctions during maintenance operations.

The software of the programmable logic controller Simatic S7-1200 contains a vulnerability that causes loss of access to the device during the processing of specific TCP/IP packets...

7.8CVSS5.5AI score0.00342EPSS
Exploits1References5Affected Software1
Rows per page
Query Builder