16 matches found
The vulnerability of the software for the Hitachi Energy MicroSCADA X SYS600 system, related to errors in using standard permissions, allows a perpetrator to trigger a maintenance failure.
The vulnerability of the software used in the Hitachi Energy MicroSCADA X SYS600 equipment management system is related to errors in the use of standard permissions. Exploiting this vulnerability could allow an intruder to cause maintenance failures...
The vulnerability of UEFI microprogramming systems of Intel processors allows a hacker to trigger a malfunction during maintenance.
The vulnerability of UEFI microprogramming systems of Intel processors is related to deficiencies in access control. Exploiting this vulnerability can allow an attacker to cause a system failure...
The vulnerability of the microprogramming software for Schneider Electric’s programmable logic controllers (PLC) models M241, M251, M258, and LMC058 is related to errors in processing input data. This vulnerability allows attackers to trigger maintenance failures and compromise the confidentiality, integrity, and accessibility of protected information.
The vulnerability of the microprogrammed software of Schneider Electric’s programmable logic controllers PLC models M241, M251, M258, and LMC058 is related to errors in processing input data. Exploiting this vulnerability can allow an attacker to trigger maintenance failures and compromise the...
The vulnerability of Intel’s microprogrammed chipset and processor software, related to integer overflow, allows attackers to trigger malfunctions during maintenance operations.
The vulnerability of Intel chipset and processor microprogramming software is related to integer overflow. Exploiting this vulnerability can allow a remote attacker to cause system failures...
The vulnerability of Fanuc Series 32i CNC controller’s microprogramming software, related to resource management errors, allows a intruder to cause maintenance failures.
The vulnerability of Fanuc Series 32ii CNC controller’s microprogramming software is related to resource management errors. Exploiting this vulnerability can allow a malicious actor to cause maintenance failures...
The vulnerability in the implementation of the RPC (Remote Procedure Call) protocol of Siemens’ process control systems such as SIMATIC PCS 7, OpenPCS 7, and Siemens’ SCADA system SIMATIC WinCC allows a attacker to trigger maintenance failures.
The vulnerability of the RPC Remote Procedure Call protocol implementation in Siemens SIMATIC PCS 7, OpenPCS 7, and SCADA systems like SIMATIC WinCC is related to errors in pointer assignment. Exploiting this vulnerability can allow an attacker to cause service interruptions remotely...
The vulnerability of the microprogrammed software of the PowerFlex 527 variable frequency converter, related to uncontrolled resource consumption, allows a intruder to trigger a maintenance failure.
The vulnerability of the microprogrammed software of the PowerFlex 527 variable frequency converter is related to uncontrolled resource consumption. Exploiting this vulnerability could allow a malicious actor to cause maintenance failures by sending specially crafted network requests remotely...
The vulnerability of the NEXO-OS operating system in the Bosch Nexo cordless nutrunner and Bosch Nexo special cordless nutrunner tools used in production lines allows a intruder to trigger a service failure or execute arbitrary code.
The vulnerability of the NEXO-OS operating system for tools used in production line maintenance with the Bosch Nexo cordless nutrunner and Bosch Nexo special cordless nutrunner is related to buffer overflow in the stack. Exploiting this vulnerability can allow a malicious actor to trigger...
The vulnerability of the NEXO-OS operating system in the Bosch Nexo cordless nutrunner and Bosch Nexo special cordless nutrunner tools used in production lines allows a intruder to trigger a service failure or execute arbitrary code.
The vulnerability of the NEXO-OS operating system for tools used in production line maintenance with the Bosch Nexo cordless nutrunner and Bosch Nexo special cordless nutrunner is related to buffer overflow in the stack. Exploiting this vulnerability could allow a malicious actor to trigger...
The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to uncontrolled resource consumption, allows a intruder to trigger a service failure.
The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software is related to uncontrolled resource consumption. Exploiting this vulnerability could allow a malicious actor to trigger maintenance failures remotely...
The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert allows a intruder to trigger maintenance failures.
The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert lies in the storage of data beyond the buffer boundaries. Exploiting this vulnerability could allow a malicious actor to trigger service...
The vulnerability of the software and hardware components of SCADA systems such as ABB Relion 611, Relion 615, Relion 620, Relion REF615, Relion RED615, Relion RER620, Relion RER615, Relion REX640, eVD4, REC615, and SMU615 lies in improper initialization of resources, which allows attackers to trigger maintenance-related failures.
The vulnerability of the software and hardware components of SCADA systems such as ABB Relion 611, Relion 615, Relion 620, Relion REF615, Relion RED615, Relion RER620, Relion RER615, Relion REX640, eVD4, REC615, and SMU615 is related to improper initialization of resources. Exploiting this...
The vulnerability of the VXLAN Operation, Administration, and Maintenance (OAM) function of the Cisco NX-OS operating system allows a attacker to trigger a maintenance failure.
The vulnerability of the VXLAN Operation, Administration, and Maintenance OAM function of the Cisco NX-OS operating system is related to errors in processing input data. Exploiting this vulnerability can allow a malicious actor to trigger maintenance failures remotely...
The vulnerability of the microprogrammed software of the modular controller for the automation of transformer substations of Schneider Electric Easergy T300 (HU250) – related to uncontrolled resource consumption – allows a intruder to trigger a maintenance failure.
The vulnerability of the microprogrammed control module software for Schneider Electric Easergy T300 HU250 for transformer substations automation involves an uncontrolled consumption of resources. Exploiting this vulnerability could allow a malicious actor to cause malfunctions in the system due ...
The vulnerability in the implementation of 3D-acceleration functions for hypervisors such as VMware ESXi, VMware Fusion, and Vmware Workstation allows attackers to exploit it to disclose sensitive information or cause system failures during maintenance.
The vulnerability of the 3D-acceleration function implementation in VMware ESXi, VMware Fusion, and Vmware Workstation relates to reading data beyond the buffer boundaries in memory. Exploiting this vulnerability can allow a malicious actor to disclose sensitive information or cause system failur...
The vulnerability of the JunOS operating system in Juniper switches of the QFX5000 and EX4600 series allows a hacker to cause maintenance failures.
The vulnerability of the JunOS operating system in Juniper switches of the QFX5000 and EX4600 series is related to errors in processing input data. Exploiting this vulnerability can allow an attacker to cause service interruptions...