Lucene search
K

19 matches found

BDU FSTEC
BDU FSTEC
added 2025/05/28 12:0 a.m.1 views

The vulnerability of the dcpd service in the microprogramming software of Siemens Scalance LPE9403 allows a hacker to trigger a maintenance failure.

The vulnerability of the dcpd service in Siemens Scalance LPE9403 microprogramming software lies in the reading outside the buffer boundaries. Exploiting this vulnerability can allow a malicious actor to cause a service failure by sending specially crafted malware packages...

4.3CVSS5.7AI score0.00187EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2025/05/05 12:0 a.m.1 views

The vulnerability of the Flexible PIC Concentrator module’s operating system, Juniper Networks Junos OS, allows a hacker to trigger a maintenance failure.

The vulnerability of the Flexible PIC Concentrator FPC module of Juniper Networks’ Junos OS is related to buffer overflow in dynamic memory. Exploiting this vulnerability can allow a malicious actor to trigger a service failure by sending a specially crafted DHCP packet...

7.5CVSS5.8AI score0.00906EPSS
Exploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2025/03/17 12:0 a.m.1 views

The vulnerability of the Vnet/IP SCADA system of Yokogawa CENTUM VP allows a intruder to execute arbitrary code and trigger a maintenance failure.

The vulnerability of the Vnet/IP SCADA system of Yokogawa CENTUM VP is related to a countable loss of significance. Exploiting this vulnerability allows a malicious actor to execute arbitrary commands and cause service failures by sending specially crafted packets...

7.5CVSS5.9AI score0.00003EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2024/07/23 12:0 a.m.1 views

The vulnerability of Siemens SCALANCE industrial switches, related to bypassing authentication through spoofing, allows a intruder to trigger a maintenance failure.

The vulnerability of Siemens SCALANCE industrial switches relates to the ability to bypass authentication through spoofing. Exploiting this vulnerability can allow a malicious actor to trigger a service failure remotely...

6.1CVSS5.4AI score0.00067EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2024/04/10 12:0 a.m.1 views

The vulnerability of the software environment of Siemens Tecnomatix Plant Simulation, related to the manipulation of the zero indicator, allows a perpetrator to trigger a service failure.

The vulnerability of the software environment of Siemens Tecnomatix Plant Simulation relates to the manipulation of the zero indicator. Exploiting this vulnerability can allow attackers to trigger a maintenance failure using specially created SPP files...

5.5CVSS5.8AI score0.0004EPSS
Exploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2024/04/10 12:0 a.m.1 views

The vulnerability of the software environment of Siemens Tecnomatix Plant Simulation, related to the manipulation of the zero indicator, allows a perpetrator to trigger a service failure.

The vulnerability of the software environment of Siemens Tecnomatix Plant Simulation relates to the manipulation of the zero indicator. Exploiting this vulnerability can allow attackers to trigger a maintenance failure using specially created SPP files...

5.5CVSS5.8AI score0.0004EPSS
Exploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2024/02/06 12:0 a.m.1 views

The vulnerability of the NEXO-OS operating system in the Bosch Nexo cordless nutrunner and Bosch Nexo special cordless nutrunner tools used in production lines allows a intruder to trigger a service failure or execute arbitrary code.

The vulnerability of the NEXO-OS operating system for tools used in production line maintenance, such as the Bosch Nexo cordless nutrunner and the Bosch Nexo special cordless nutrunner, exists due to the lack of protective measures for the website structure. Exploiting this vulnerability can allo...

5.3CVSS6.6AI score0.00104EPSS
Exploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/06/09 12:0 a.m.1 views

The vulnerability of the Flexible PIC Concentrator module’s operating system, Juniper Networks Junos OS, allows a hacker to trigger a maintenance failure.

The vulnerability of the Flexible PIC Concentrator FPC module of Juniper Networks’ Junos OS is related to memory release errors. Exploiting this vulnerability could allow a remote attacker to cause service interruptions...

6.5CVSS6.6AI score0.00121EPSS
Exploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/04/13 12:0 a.m.1 views

The vulnerability of NETGEAR GS808E switch’s microprogramming software, related to the lack of protection for service data, allows a intruder to trigger a maintenance failure.

The vulnerability of NETGEAR GS808E switch microprogramming software is related to the lack of protection for service data. Exploiting this vulnerability could allow an intruder to cause a service failure...

3.2CVSS0.00059EPSS
Exploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/03/15 12:0 a.m.1 views

The vulnerability of the Schneider Electric EcoStruxure Control Expert programming tool, related to the execution of operations beyond the buffer boundaries, allows a intruder to trigger a maintenance failure or execute arbitrary code.

The vulnerability of the Schneider Electric EcoStruxure Control Expert programming tool relates to the execution of operations beyond the buffer boundaries. Exploiting this vulnerability could allow an attacker to trigger a maintenance failure or execute arbitrary code by opening a specially...

8.6CVSS0.00418EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2021/01/28 12:0 a.m.1 views

The vulnerability of the microprogramming software of the CloudEngine 1800V switch allows a intruder to trigger a maintenance failure.

The vulnerability of the CloudEngine 1800V microcontroller software is related to resource management errors. Exploiting this vulnerability could allow a malicious actor to trigger a service failure through a specially crafted message...

7.8CVSS0.00182EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2020/10/07 12:0 a.m.1 views

The vulnerability of the Ethernet OAM component of the JunOS operating system, which allows a hacker to trigger a maintenance failure.

The vulnerability of the JunOS operating system’s Ethernet component is related to deficiencies in handling exceptional states. Exploiting this vulnerability can allow a malicious actor to cause service interruptions remotely...

7.8CVSS0.00536EPSS
Exploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2019/09/27 12:0 a.m.0 views

The vulnerability of the Virtual Shell (VSH) service in the NX-OS network operating system allows a hacker to trigger a maintenance failure or cause an emergency shutdown of the application.

The vulnerability of the Virtual Shell VSH service in the NX-OS network operating system is related to uncontrolled resource consumption. Exploiting this vulnerability could allow a malicious actor to cause an application to terminate abnormally or trigger a service failure remotely...

7.7CVSS5.5AI score0.00995EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2018/10/19 12:0 a.m.2 views

The vulnerability of the Microsoft Hyper-V operating system’s network switch allows a attacker to cause a failure in the host operating system’s maintenance.

The vulnerability of the Microsoft Hyper-V operating system’s network switch is due to insufficient validation of input data. Exploiting this vulnerability can allow an attacker to cause a service failure for the host operating system through a specially created payload...

4.7CVSS7.8AI score0.01498EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2018/10/19 12:0 a.m.3 views

The vulnerability of the Microsoft Hyper-V operating system’s network switch allows a attacker to cause a failure in the host operating system’s maintenance.

The vulnerability of the Microsoft Hyper-V operating system’s network switch is due to insufficient validation of input data. Exploiting this vulnerability can allow an attacker to cause a service failure for the host operating system through a specially created payload...

4.7CVSS7.8AI score0.00308EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2018/04/12 12:0 a.m.1 views

The vulnerability in Siemens SIMATIC and OpenPCS 7 industrial equipment, related to insufficient verification of input data, allows a intruder to trigger a service failure.

The vulnerability in Siemens SIMATIC and OpenPCS 7 industrial equipment exists due to insufficient verification of input data. Exploiting this vulnerability can allow a malicious actor to trigger a maintenance failure by sending a specially crafted request through the remote control service of...

7.8CVSS5.5AI score0.00433EPSS
Exploits0References5Affected Software1
BDU FSTEC
BDU FSTEC
added 2015/10/14 12:0 a.m.1 views

The vulnerability of the NX-OS network operating system allows a hacker to induce a maintenance failure.

The vulnerability of the NX-OS network operating system is related to resource management errors. Exploiting this vulnerability could allow a malicious actor, operating remotely, to cause service interruptions by establishing connections with Java applications...

5CVSS0.00918EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2015/10/13 12:0 a.m.2 views

The vulnerability of the NX-OS network operating system allows a hacker to induce a maintenance failure.

The vulnerability of the NX-OS network operating system arises due to buffer overflow. Exploiting this vulnerability can allow an attacker to cause a service failure by sending a specially crafted ARP packet...

6.1CVSS0.00806EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2015/04/28 12:0 a.m.2 views

The vulnerability of the microprogramming software of the Cisco ASA security device allows a remote attacker to induce a maintenance failure.

The vulnerability of the microprogramming software of the Cisco ASA security device in the XML processing module when using Clientless SSL VPN, AnyConnect SSL VPN, or AnyConnect IKEv2 VPN allows a malicious actor to trigger a service failure a malfunction in the VPN operation or a system restart ...

7.8CVSS0.01051EPSS
Exploits0References2
Rows per page
Query Builder