Lucene search
+L

66 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•26 views

EUVD-2019-16387

Malware in sbrugna...

6.5CVSS7.1AI score0.01049EPSS
SaveExploits1References4
EUVD
EUVD
•added 2025/10/07 12:30 a.m.•17 views

EUVD-2013-2701

Malware in sbrugna...

10CVSS5.8AI score0.02105EPSS
SaveExploits0References2
EUVD
EUVD
•added 2025/10/07 12:30 a.m.•15 views

EUVD-2016-9222

Malware in sbrugna...

7.8CVSS7.3AI score0.02162EPSS
SaveExploits2References3
RedhatCVE
RedhatCVE
•added 2025/05/22 5:23 a.m.•25 views

CVE-2019-6833

A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...

6.5CVSS7AI score0.01049EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/05/22 1:14 a.m.•17 views

CVE-2013-2762

The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data...

10CVSS5.9AI score0.02105EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2022/02/09 11:15 p.m.•12 views

CVE-2021-22817

A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...

7.8CVSS7.1AI score0.002EPSS
SaveExploits0References2
osv_cve
osv_cve
•added 2022/02/09 11:15 p.m.•33 views

CVE-2021-22817

A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...

7.8CVSS5.8AI score0.002EPSS
SaveExploits0References1
NVD
NVD
•added 2022/02/09 11:15 p.m.•53 views

CVE-2021-22817

A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...

7.8CVSS0.002EPSS
SaveExploits0References1
Prion
Prion
•added 2022/02/09 11:15 p.m.•38 views

Design/Logic Flaw

A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...

4.6CVSS7.4AI score0.002EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/02/09 10:05 p.m.•50 views

CVE-2021-22817

A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...

7.7AI score0.002EPSS
SaveExploits0References1
CVE
CVE
•added 2022/02/09 10:05 p.m.•112 views

CVE-2021-22817

CVE-2021-22817 affects Schneider Electric Harmony/Magelis iPC Series, Vijeo Designer (pre V6.2 SP11 HotFix 4), and Vijeo Designer Basic (pre V1.2.1). The root cause is a CWE-276 Incorrect Default Permissions that can allow unauthorized access to the base installation directory, enabling local pri...

7.8CVSS7.4AI score0.002EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•8 views

CVE-2021-22817: Incorrect Default Permissions

A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...

7.8CVSS7.3AI score0.002EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2022/02/09 12:00 a.m.•8 views

PT-2022-9287

Name of the Vulnerable Software and Affected Versions Harmony/Magelis iPC Series All Versions Vijeo Designer versions prior to V6.2 SP11 Multiple HotFix 4 Vijeo Designer Basic versions prior to V1.2.1 Description A vulnerability exists that could cause unauthorized access to the base installation...

7.8CVSS0.002EPSS
SaveExploits0References4
ICS
ICS
•added 2020/02/13 12:00 a.m.•93 views

Schneider Electric Magelis HMI Panels

1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: Magelis HMI Panel Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a...

6.5CVSS6.8AI score0.01049EPSS
SaveExploits1References5
NVD
NVD
•added 2019/09/17 8:15 p.m.•33 views

CVE-2019-6833

A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...

6.5CVSS6.5AI score0.01049EPSS
SaveExploits1References2
Prion
Prion
•added 2019/09/17 8:15 p.m.•33 views

Design/Logic Flaw

A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...

4.3CVSS6.5AI score0.01049EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2019/09/17 7:36 p.m.•42 views

CVE-2019-6833

A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...

6.6AI score0.01049EPSS
SaveExploits1References2
CVE
CVE
•added 2019/09/17 7:36 p.m.•139 views

CVE-2019-6833

CVE-2019-6833 affects Schneider Electric Magelis HMI Panels (HMIGTO/HMISTO/XBTGH/HMIGTU/HMIGTUX/HMISCU/HMISTU/XBTGT/XBTGC/HMIGXO/HMIGXU), where a high rate of frames can cause a temporary HMI freeze; after the rate subsides, buffered commands are processed. Affected firmware versions: all listed ...

6.5CVSS6.5AI score0.01049EPSS
SaveExploits1References2Affected Software1
Vulnrichment
Vulnrichment
•added 2019/09/17 7:36 p.m.•9 views

CVE-2019-6833

A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...

6.6AI score0.01049EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/09/17 12:00 a.m.•17 views

CVE-2019-6833: Improper Check for Unusual or Exceptional Conditions

A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...

6.5CVSS6.8AI score0.01049EPSS
SaveExploits1References3
Rows per page
Query Builder