55 matches found
EUVD-2019-16387
Malware in sbrugna...
EUVD-2013-2701
Malware in sbrugna...
EUVD-2016-9222
Malware in sbrugna...
CVE-2019-6833
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...
CVE-2013-2762
The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data...
CVE-2021-22817
A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...
CVE-2021-22817
A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...
Design/Logic Flaw
A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...
CVE-2021-22817
CVE-2021-22817 affects Schneider Electric Harmony/Magelis iPC Series, Vijeo Designer (pre V6.2 SP11 HotFix 4), and Vijeo Designer Basic (pre V1.2.1). The root cause is a CWE-276 Incorrect Default Permissions that can allow unauthorized access to the base installation directory, enabling local pri...
CVE-2021-22817
A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series All Versions, Vijeo Designer All Versions prior to V6.2 SP11 Multiple HotFix 4,...
Schneider Electric Magelis HMI Panels
1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: Magelis HMI Panel Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a...
CVE-2019-6833
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...
Design/Logic Flaw
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...
CVE-2019-6833
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...
CVE-2019-6833
CVE-2019-6833 affects Schneider Electric Magelis HMI Panels (HMIGTO/HMISTO/XBTGH/HMIGTU/HMIGTUX/HMISCU/HMISTU/XBTGT/XBTGC/HMIGXO/HMIGXU), where a high rate of frames can cause a temporary HMI freeze; after the rate subsides, buffered commands are processed. Affected firmware versions: all listed ...
CVE-2019-6833
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU, which could cause a temporary freeze of the HMI when a high rate of frames is receive...
Schneider Electric Magelis SCU HMISCU8A5 Control Panel Detection
Binary data 751184.prm...
Schneider Electric Magelis XBT XBTGT5340 Control Panel Detection
Binary data 751203.prm...
Schneider Electric Magelis GTO HMIGTO2310 Control Panel Detection
Binary data 751192.prm...
Schneider Electric Magelis GTO HMIGTO2300 Control Panel Detection
Binary data 751191.prm...