15 matches found
EUVD-2025-11895
Malicious code in bioql PyPI...
EUVD-2025-11900
Malicious code in bioql PyPI...
CVE-2025-25984
An issue in Macro-video Technologies Co.,Ltd V380E6C1 IP camera HwHsAKPIQpWFXHR 1020302 allows a physically proximate attacker to execute arbitrary code via UART component...
CVE-2025-25985
An issue in Macro-video Technologies Co.,Ltd V380E6C1 IP camera HwHsAKPIQpWFXHR 1020302 allows a physically proximate attacker to execute arbitrary code via the /mnt/mtd/mvconf/wifi.ini and /mnt/mtd/mvconf/userinfo.ini components...
CVE-2025-25985
An issue in Macro-video Technologies Co.,Ltd V380E6C1 IP camera HwHsAKPIQpWFXHR 1020302 allows a physically proximate attacker to execute arbitrary code via the /mnt/mtd/mvconf/wifi.ini and /mnt/mtd/mvconf/userinfo.ini components...
CVE-2025-25985
An issue in Macro-video Technologies Co.,Ltd V380E6C1 IP camera HwHsAKPIQpWFXHR 1020302 allows a physically proximate attacker to execute arbitrary code via the /mnt/mtd/mvconf/wifi.ini and /mnt/mtd/mvconf/userinfo.ini components...
CVE-2025-25983
An issue in Macro-video Technologies Co.,Ltd V380 Pro android application 2.1.44 and V380 Pro android application 2.1.64 allows an attacker to obtain sensitive information via the QE code based sharing component...
CVE-2025-25985
CVE-2025-25985 affects Macro-video Technologies Co.,Ltd V380E6_C1 IP camera (version 1020302). The issue allows a physically proximate attacker to trigger arbitrary code execution via the vulnerable files /mnt/mtd/mvconf/wifi.ini and /mnt/mtd/mvconf/user_info.ini within the device’s filesystem. C...
CVE-2025-25983
CVE-2025-25983 affects Macro-video V380 Pro Android apps 2.1.44 and 2.1.64 through the app’s QE code based sharing component. The issue enables disclosure of sensitive data via the QR-based sharing flow: the QR payload encodes a device id, a key, and an encrypted message; practical analysis shows...
CVE-2025-25984
An issue in Macro-video Technologies Co.,Ltd V380E6C1 IP camera HwHsAKPIQpWFXHR 1020302 allows a physically proximate attacker to execute arbitrary code via UART component...
CVE-2025-25984
An issue in Macro-video Technologies Co.,Ltd V380E6C1 IP camera HwHsAKPIQpWFXHR 1020302 allows a physically proximate attacker to execute arbitrary code via UART component...
PT-2025-17341 · Macro Video Technologies Co. · V380E6 C1 Ip Camera
Name of the Vulnerable Software and Affected Versions: Macro-video Technologies Co.,Ltd V380E6 C1 IP camera version 1020302 Description: An issue in the V380E6 C1 IP camera allows a physically proximate attacker to execute arbitrary code via the /mnt/mtd/mvconf/wifi.ini and /mnt/mtd/mvconf/user...
PT-2025-17340 · Macro Video Technologies Co. · V380E6 C1 Ip Camera
Name of the Vulnerable Software and Affected Versions: Macro-video Technologies Co.,Ltd V380E6 C1 IP camera affected versions not specified Description: The issue allows a physically proximate attacker to execute arbitrary code via the UART component. Recommendations: At the moment, there is no...
CVE-2025-25985
An issue in Macro-video Technologies Co.,Ltd V380E6C1 IP camera HwHsAKPIQpWFXHR 1020302 allows a physically proximate attacker to execute arbitrary code via the /mnt/mtd/mvconf/wifi.ini and /mnt/mtd/mvconf/userinfo.ini components...
CVE-2025-25984
CVE-2025-25984 affects Macro-video Technologies Co.,Ltd V380E6_C1 IP camera (HW: Hw_HsAKPIQp_WF_XHR, 1020302). Connected sources describe a vulnerability enabling a physically proximate attacker to gain arbitrary code execution via the UART debug interface. Exploitation details include obtaining ...