Lucene search
+L

631 matches found

ICS
ICS
added 2025/01/14 12:00 a.m.12 views

Schneider Electric Modicon M340 and BMXNOE0100/0110, BMXNOR0200H (Update B)

RISK EVALUATION Successful exploitation of this vulnerability could cause information disclosure of a restricted web page, modification of a web page and a denial of service when specific web pages are modified and restricted functions are invoked. 2. RECOMMENDED PRACTICES CISA reminds...

8.8CVSS7.4AI score0.00349EPSS
SaveExploits0References11
BDU FSTEC
BDU FSTEC
added 2024/12/09 12:00 a.m.17 views

The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers allows a perpetrator to carry out a “man-in-the-middle” attack.

The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers is related to insufficient verification of input data. Exploiting this vulnerability can allow an attacker to carry out a “man-in-the-middle” attack remotely...

6.5CVSS5.4AI score0.00499EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2024/12/09 12:00 a.m.13 views

The vulnerability of the Diffie-Hellman algorithm in microprogrammed logic controllers (PLCs) from Schneider Electric Modicon M340 CPU BMXP34 allows a attacker to execute a “man-in-the-middle” attack.

The vulnerability of the Diffie-Hellman algorithm in microprogrammed logic controllers PLCs from Schneider Electric Modicon M340 CPU BMXP34 lies in the ability to bypass authentication through spoofing. Exploiting this vulnerability allows a malicious actor to carry out a “man-in-the-middle” atta...

7.6CVSS5.5AI score0.00501EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2024/12/09 12:00 a.m.15 views

The vulnerability of microprogrammed software for Schneider Electric Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the lack of checks for the integrity of messages during transmission over communication channels. This allows attackers to disclose sensitive information or cause malfunctions in the system.

The vulnerability of microprogrammed logic controllers PLCs from Schneider Electric, such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, stems from the lack of checks for the integrity of messages during transmission over communication...

7.6CVSS5.5AI score0.00292EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.10 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2024-8933)

A vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themselves inside the logical network while a valid user uploads or downloads a project...

7.7CVSS5.5AI score0.00501EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.12 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Authentication Bypass By Spoofing (CVE-2024-8935)

A vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is...

7.7CVSS5.5AI score0.00501EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.8 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2024-8938)

Arbitrary code execution can potentially be achieved after a successful Man-In-The Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. This plugin only works with Tenable.ot. Please visit...

9.2CVSS6AI score0.00532EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2024/11/15 12:00 a.m.11 views

The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers (PLCs), such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, allows a attacker to execute a “man-in-the-middle” attack.

The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers PLCs such as Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the execution of operations outside the buffer in memory. Exploiting th...

8.1CVSS6.1AI score0.00586EPSS
SaveExploits0References2Affected Software1
CNNVD
CNNVD
added 2024/11/13 12:00 a.m.7 views

Schneider Electric Modicon M340 输入验证错误漏洞

The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. An input validation error vulnerability exists in the Schneider Electric Modicon M340, which stems from the presence of an improper inpu...

8.3CVSS6.3AI score0.00499EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/11/13 12:00 a.m.14 views

Schneider Electric Modicon M340 缓冲区错误漏洞

The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. The Schneider Electric Modicon M340 suffers from a buffer error vulnerability that originates from improperly restricted memory buffer...

8.3CVSS7.6AI score0.00586EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/11/13 12:00 a.m.11 views

Schneider Electric Modicon M340 安全漏洞

The Schneider Electric Modicon M340 is a medium-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. A security vulnerability exists in the Schneider Electric Modicon M340 that arises from improper implementation of message integrity...

7.5CVSS6.4AI score0.00292EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/11/13 12:00 a.m.10 views

Schneider Electric Modicon M340 安全漏洞

The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. A security vulnerability exists in the Schneider Electric Modicon M340 that stems from the presence of an authentication bypass via...

7.7CVSS6.4AI score0.00501EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2024/11/12 12:00 a.m.12 views

PT-2024-9212 · Schneider Electric · Modicon M340 Cpu Bmxp34

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34 affected versions not specified Description: The issue is related to insufficient input validation in the Modbus protocol implementation of the Schneider Electric Modicon M340 CPU BMXP34 programmable...

8.3CVSS6.9AI score0.00499EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2024/11/12 12:00 a.m.9 views

PT-2024-9214 · Schneider Electric · Schneider Electric Modicon M340 Cpu Bmxp34

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34 affected versions not specified Description: The issue is related to an authentication bypass vulnerability in the Diffie-Hellman algorithm, which can be exploited to conduct a Man-In-The-Middle atta...

7.7CVSS7.3AI score0.00501EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2024/11/12 12:00 a.m.46 views

PT-2024-9213 · Schneider Electric · Modicon Mc80 Bmkc80 +2

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU affected versions not specified Description: A vulnerability exists that could cause a potential arbitrary code execution after a...

9.2CVSS7.7AI score0.00532EPSS
SaveExploits0References9
BDU FSTEC
BDU FSTEC
added 2024/06/24 12:00 a.m.12 views

The vulnerability of the microprogramming software of Schneider Electric’s programmable logic controller Modicon M340 and its network modules, Modicon M340 BMXNOE0100, Modicon M340 BMXNOE0110, stems from the use of files and directories accessible to external parties. This allows attackers to disrupt the device’s firmware updates and cause improper operation of the web server.

The vulnerability of the microprogramming software of Schneider Electric’s programmable logic controller Modicon M340, as well as its network modules Modicon M340 BMXNOE0100 and Modicon M340 BMXNOE0110, stems from the use of files and directories accessible to external parties. Exploiting this...

6.5CVSS5.4AI score0.00351EPSS
SaveExploits0References2
CNVD
CNVD
added 2024/06/18 12:00 a.m.14 views

Schneider Electric Modicon M340 Denial of Service Vulnerability

The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. A denial of service vulnerability exists in the Schneider Electric Modicon M340, which can be exploited by an attacker to prevent a use...

6.5CVSS6.7AI score0.00351EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/06/12 12:00 a.m.8 views

Schneider Electric Modicon M340 安全漏洞

The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. A denial of service vulnerability exists in the Schneider Electric Modicon M340, which can be exploited by an attacker to prevent a use...

6.5CVSS6.6AI score0.00351EPSS
SaveExploits0References2
ICS
ICS
added 2024/06/11 12:00 a.m.10 views

Schneider Electric Modicon M340, BMXNOE0100, and BMXNOE0110 (Update A)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

6.5CVSS6.7AI score0.00351EPSS
SaveExploits0References11
Tenable Nessus
Tenable Nessus
added 2024/04/11 12:00 a.m.16 views

Schneider Electric Modicon M340 GoAhead Webserver Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2015-7937)

Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data. This plugin only works with Tenable.ot. Please visit...

10CVSS6.3AI score0.07351EPSS
SaveExploits1References4
Rows per page
Query Builder