631 matches found
Schneider Electric Modicon M340 and BMXNOE0100/0110, BMXNOR0200H (Update B)
RISK EVALUATION Successful exploitation of this vulnerability could cause information disclosure of a restricted web page, modification of a web page and a denial of service when specific web pages are modified and restricted functions are invoked. 2. RECOMMENDED PRACTICES CISA reminds...
The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers allows a perpetrator to carry out a “man-in-the-middle” attack.
The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers is related to insufficient verification of input data. Exploiting this vulnerability can allow an attacker to carry out a “man-in-the-middle” attack remotely...
The vulnerability of the Diffie-Hellman algorithm in microprogrammed logic controllers (PLCs) from Schneider Electric Modicon M340 CPU BMXP34 allows a attacker to execute a “man-in-the-middle” attack.
The vulnerability of the Diffie-Hellman algorithm in microprogrammed logic controllers PLCs from Schneider Electric Modicon M340 CPU BMXP34 lies in the ability to bypass authentication through spoofing. Exploiting this vulnerability allows a malicious actor to carry out a “man-in-the-middle” atta...
The vulnerability of microprogrammed software for Schneider Electric Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the lack of checks for the integrity of messages during transmission over communication channels. This allows attackers to disclose sensitive information or cause malfunctions in the system.
The vulnerability of microprogrammed logic controllers PLCs from Schneider Electric, such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, stems from the lack of checks for the integrity of messages during transmission over communication...
Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2024-8933)
A vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themselves inside the logical network while a valid user uploads or downloads a project...
Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Authentication Bypass By Spoofing (CVE-2024-8935)
A vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is...
Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2024-8938)
Arbitrary code execution can potentially be achieved after a successful Man-In-The Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. This plugin only works with Tenable.ot. Please visit...
The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers (PLCs), such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, allows a attacker to execute a “man-in-the-middle” attack.
The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers PLCs such as Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the execution of operations outside the buffer in memory. Exploiting th...
Schneider Electric Modicon M340 输入验证错误漏洞
The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. An input validation error vulnerability exists in the Schneider Electric Modicon M340, which stems from the presence of an improper inpu...
Schneider Electric Modicon M340 缓冲区错误漏洞
The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. The Schneider Electric Modicon M340 suffers from a buffer error vulnerability that originates from improperly restricted memory buffer...
Schneider Electric Modicon M340 安全漏洞
The Schneider Electric Modicon M340 is a medium-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. A security vulnerability exists in the Schneider Electric Modicon M340 that arises from improper implementation of message integrity...
Schneider Electric Modicon M340 安全漏洞
The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. A security vulnerability exists in the Schneider Electric Modicon M340 that stems from the presence of an authentication bypass via...
PT-2024-9212 · Schneider Electric · Modicon M340 Cpu Bmxp34
Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34 affected versions not specified Description: The issue is related to insufficient input validation in the Modbus protocol implementation of the Schneider Electric Modicon M340 CPU BMXP34 programmable...
PT-2024-9214 · Schneider Electric · Schneider Electric Modicon M340 Cpu Bmxp34
Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34 affected versions not specified Description: The issue is related to an authentication bypass vulnerability in the Diffie-Hellman algorithm, which can be exploited to conduct a Man-In-The-Middle atta...
PT-2024-9213 · Schneider Electric · Modicon Mc80 Bmkc80 +2
Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU affected versions not specified Description: A vulnerability exists that could cause a potential arbitrary code execution after a...
The vulnerability of the microprogramming software of Schneider Electric’s programmable logic controller Modicon M340 and its network modules, Modicon M340 BMXNOE0100, Modicon M340 BMXNOE0110, stems from the use of files and directories accessible to external parties. This allows attackers to disrupt the device’s firmware updates and cause improper operation of the web server.
The vulnerability of the microprogramming software of Schneider Electric’s programmable logic controller Modicon M340, as well as its network modules Modicon M340 BMXNOE0100 and Modicon M340 BMXNOE0110, stems from the use of files and directories accessible to external parties. Exploiting this...
Schneider Electric Modicon M340 Denial of Service Vulnerability
The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. A denial of service vulnerability exists in the Schneider Electric Modicon M340, which can be exploited by an attacker to prevent a use...
Schneider Electric Modicon M340 安全漏洞
The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. A denial of service vulnerability exists in the Schneider Electric Modicon M340, which can be exploited by an attacker to prevent a use...
Schneider Electric Modicon M340, BMXNOE0100, and BMXNOE0110 (Update A)
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Schneider Electric Modicon M340 GoAhead Webserver Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2015-7937)
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data. This plugin only works with Tenable.ot. Please visit...