13 matches found
EUVD-2025-7765
Malicious code in bioql PyPI...
EUVD-2025-14669
Malicious code in bioql PyPI...
EUVD-2025-7767
Malicious code in bioql PyPI...
EUVD-2025-14672
Malicious code in bioql PyPI...
EUVD-2023-31185
Malicious code in bioql PyPI...
Siemens SCALANCE LPE9403 Stack-Based Buffer Overflow (CVE-2025-40579)
A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions V4.0 HF0. Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non- privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition...
Siemens SCALANCE LPE9403 Out-of-Bounds Read (CVE-2025-40577)
A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions. Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcp...
Siemens SCALANCE LPE9403 Information Disclosure Vulnerability
Siemens SCALANCE LPE9403 is a local processing engine for industrial field data processing from Siemens. It is used to capture, collect and pre-process industrial field data. An information disclosure vulnerability exists in the Siemens SCALANCE LPE9403 6GK5998-3GS00-2AC2, which can be exploited ...
CVE-2023-27409
A vulnerability has been identified in SCALANCE LPE9403 All versions V2.1. A path traversal vulnerability was found in the deviceinfo binary via the mac parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read the contents of any file...
CVE-2025-40572
A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions V4.0 HF0. Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to access sensitive information stored on the device...
CVE-2025-40575
CVE-2025-40575 affects Siemens SCALANCE LPE9403 devices (all versions
CVE-2025-40572
CVE-2025-40572 affects Siemens SCALANCE LPE9403 (6GK5998-3GS00-2AC2). All versions below V4.0 HF0 are affected by an information-disclosure vulnerability caused by incorrect permission assignment to critical resources. A non-privileged local attacker could access sensitive information stored on t...
CVE-2025-27394
A vulnerability has been identified in SCALANCE LPE9403 6GK5998-3GS00-2AC2 All versions V4.0. Affected devices do not properly sanitize user input when creating new SNMP users. This could allow an authenticated highly-privileged remote attacker to execute arbitrary code on the device...