7434 matches found
Acronis DeviceLock DLP 代码问题漏洞
Acronis DeviceLock DLP is a terminal security protection system developed by the Swiss company Acronis. It is designed to control access to peripherals and prevent data breaches. Versions of Acronis DeviceLock DLP prior to 9.0.15051.93227 contained code vulnerabilities, specifically an EXE...
Acronis DeviceLock DLP 安全漏洞
Acronis DeviceLock DLP is a terminal security system developed by the Swiss company Acronis. It is designed to control access to peripherals and prevent data breaches. Versions of Acronis DeviceLock DLP prior to 9.0.15051.93227 contained security vulnerabilities. These vulnerabilities stemmed fro...
Linux Distros Unpatched Vulnerability : CVE-2026-45990
"The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - In the Linux kernel, the following vulnerability has been resolved: slub: fix data loss and overflow in krealloc Commit 2cd8231796b5 mm/slub: allow to set node...
PT-2026-45983
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2019-25721
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25724
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2021-4479 Dräger Atlan A350 1.00 <= 1.01 DoS via Medibus Interface
Dräger Atlan A350 versions 1.00 up to and including 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can transmit malformed data to overload...
CVE-2021-4479
Dräger Atlan A350 software versions 1.00 through 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can transmit malformed data to overload th...
CVE-2019-25724
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25724
The CVE-2019-25724 entry describes a network-based Denial of Service impacting Dräger Infinity M300 patient-worn monitors running VG2.x and earlier. The underlying issue allows an attacker with access to the hospital network or Infinity Network to repeatedly trigger device reboots, driving the de...
CVE-2019-25722
The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...
EUVD-2019-20157
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25721
CVE-2019-25721 affects Dräger Infinity M300 patient-worn monitors with software VG2.3.1 and earlier. The issue is a network‑based denial-of-service vulnerability that lets network-adjacent attackers repeatedly trigger device reboots by sending malicious requests over the Infinity Network, forcing...
CVE-2026-48134
When the DLP is active, the UserCheck Web Portal contains an input-handling issue in the UserChoice flow. Under specific conditions, an attacker who can access the UserCheck Ask page could attempt to manipulate the Security Gateway's stored DLP/UserCheck incident information. This could lead to...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
PT-2026-45739
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
Azure Linux 3.0 Security Update: CBL-Mariner Releases (CVE-2026-39828)
The version of CBL-Mariner Releases installed on the remote Azure Linux 3.0 host is prior to tested version. It is, therefore, affected by a vulnerability as referenced in the CVE-2026-39828 advisory. - When an SSH server authentication callback returned PartialSuccessError with non-nil...
CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...
Sequence of Processor Instructions Leads to Unexpected Behavior
Overview admidio/admidio is a free open source user management system for websites of organizations and groups. Affected versions of this package are vulnerable to Sequence of Processor Instructions Leads to Unexpected Behavior through the fielddelete process. An attacker can permanently remove...
GHSA-XW54-C3MX-9PM3 Admidio: Any logged-in user can delete inventory fields via `mode=field_delete` — incomplete fix of #2024
Summary Commit d37ca6b27b9674238e58491cf7ba292e66898f15 "Delete item not check admin rights 2024", 2026-04-12 added a missing isAdministratorInventory gate to case 'itemdelete': in modules/inventory.php. The same fix was not applied to the sibling case 'fielddelete': handler, which destroys an...