2113 matches found
CVE-2023-45370
An issue was discovered in the SportsTeams extension for MediaWiki before 1.35.12, 1.36.x through 1.39.x before 1.39.5, and 1.40.x before 1.40.1. SportsTeams: Special:SportsManagerLogo and Special:SportsTeamsManagerLogo do not check for the sportsteamsmanager user right, and thus an attacker may ...
Online ID Generator 1.0 - Remote Code Execution Vulnerability
Title: Online ID Generator 1.0 - Remote Code Execution RCE Author: nu11secur1ty Vendor: https://www.youtube.com/watch?v=JdB9po5DTc Software: https://www.sourcecodester.com/sites/default/files/download/oretnom23/idgenerator0.zip Reference: https://portswigger.net/web-security/sql-injection...
PT-2023-8949 · Mediawiki +2 · Mediawiki Sportsteams Extension +2
Name of the Vulnerable Software and Affected Versions: MediaWiki SportsTeams extension versions prior to 1.35.12 MediaWiki SportsTeams extension versions 1.36.x through 1.39.x before 1.39.5 MediaWiki SportsTeams extension versions 1.40.x before 1.40.1 Description: An issue was discovered in the...
Nagios XI Custom Logo XSS
The vulnerability of the Custom Logo component of the Nagios XI monitoring tool is related to the lack of measures taken to protect the SQL query structure when processing the alt-text field. Exploiting this vulnerability allows a malicious actor to perform cross-site scripting attacks remotely...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25234)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions UDF in a password protected way. This...
Siemens LOGO! Web Server Buffer Copy Without Checking Size of Input (CVE-2020-7593)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants V1.81.01 - V1.81.03, LOGO! 8 BM incl. SIPLUS variants V1.82.01, LOGO! 8 BM incl. SIPLUS variants V1.82.02. A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacke...
Siemens LOGO! 8 BM Plaintext Storage of a Password (CVE-2019-10921)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated...
Siemens LOGO! 8 BM Improper Handling of Exceptional Conditions (CVE-2020-25236)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The control logic CL the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the...
Siemens LOGO! 8 BM Missing Authentication For Critical Function (CVE-2019-10919)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25233)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. This plugin only works with Tenable.ot. Please visit...
Siemens LOGO! 8 BM Insufficiently Protected Credentials (CVE-2020-25235)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins. This plugin on...
Siemens LOGO! CMR and SIMATIC RTU 3000 Incorrect Calculation of Buffer Size (CVE-2020-36475)
An issue was discovered in Mbed TLS before 2.25.0 and before 2.16.9 LTS and before 2.7.18 LTS. The calculations performed by mbedtlsmpiexpmod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie- Hellman key pairs. This plugin only works...
Siemens LOGO! 8 BM Missing Authentication For Critical Function (CVE-2020-25228)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access...
Siemens LOGO! 8 BM Use of a Broken or Risky Cryptographic Algorithm (CVE-2020-25230)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Due to the usage of an outdated cipher mode on port 10005/tcp, an attacker could extract the encryption key from a captured communication with the device. This plugin only works with Tenable.ot. Please visi...
Siemens LOGO! 8 BM Devices Improper Validation of Specified Index, Position, or Offset in Input (CVE-2022-36363)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory. This plugin only...
Siemens LOGO! Channel Accessible By Non-Endpoint (CVE-2017-12735)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. An attacker who performs a Man-in- the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. This plugin only works with Tenable.ot. Please visit...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25229)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any...
Siemens LOGO! 8 BM Devices Buffer Copy Without Checking Size of Input (CVE-2022-36361)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. Th...
Siemens LOGO! 8 BM Improper Handling of Extra Values (CVE-2019-10920)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...
Siemens LOGO! 8 BM Devices Improper Input Validation (CVE-2022-36362)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be...