Lucene search
+L

164 matches found

CNVD
CNVD
added 2018/05/04 12:00 a.m.5 views

PLCWinNT software suffers from a memory leak vulnerability

CoDeSys is a complete development environment for programmable logic control PLCs, in which simulation functions can be implemented by configuring the PLCWinNT software. A memory leak vulnerability exists in the PLCWinNT software that corresponds to the V2 version of CoDeSys. An attacker can...

8.1AI score
SaveExploits0
CNVD
CNVD
added 2018/04/12 12:00 a.m.10 views

Denial of Service Vulnerability in Tengen Controls T920 PLCs

T-920 Programmable Logic Controller PLC is a product in the T9 series Programmable Logic Controller PLC series of China TengControl Technology TENGCONTROL TECHNOLOGY. The product is widely used in tobacco, petrochemical, water and other important industrial control site. A denial of service...

6.8AI score
SaveExploits0
ATTACKERKB
ATTACKERKB
added 2018/04/03 1:29 p.m.5 views

CVE-2018-8836

Wago 750 Series PLCs with firmware version 10 and prior include a remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port...

5.3CVSS5.5AI score0.03404EPSS
SaveExploits0References4Affected Software1
NVD
NVD
added 2017/06/30 3:29 a.m.29 views

CVE-2017-7898

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions;...

9.8CVSS9.6AI score0.04894EPSS
SaveExploits0References2
Prion
Prion
added 2017/06/30 3:29 a.m.30 views

Default credentials

A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version...

5CVSS9.4AI score0.02694EPSS
SaveExploits0References2Affected Software20
Prion
Prion
added 2017/06/30 3:29 a.m.23 views

Input validation

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions;...

5CVSS9.4AI score0.04894EPSS
SaveExploits0References2Affected Software20
CVE
CVE
added 2017/06/30 2:35 a.m.100 views

CVE-2017-7902

CVE-2017-7902 affects Rockwell Automation Allen‑Bradley MicroLogix 1100 (1763-L16Axx, 16.00 and earlier) and MicroLogix 1400 (1766-L32Axx, 16.00 and earlier). The issue is nonce reuse in encryption, enabling an attacker to capture and replay a valid request until the nonce changes, potentially co...

9.8CVSS9.1AI score0.02145EPSS
SaveExploits0References2Affected Software8
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.37 views

CVE-2017-7898

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions;...

9.6AI score0.04894EPSS
SaveExploits0References2
CVE
CVE
added 2017/06/30 2:35 a.m.114 views

CVE-2017-7899

CVE-2017-7899 affects Rockwell Automation Allen-Bradley MicroLogix 1100 (1763-L16Axx, DWD) and MicroLogix 1400 (1766-L32Axx, BWAA, etc.) PLCs. The root issue is Information Exposure: user credentials are sent to the web server via HTTP GET requests, enabling potential unauthorized retrieval. Conn...

9.8CVSS9.2AI score0.04021EPSS
SaveExploits0References2Affected Software8
CNVD
CNVD
added 2017/06/05 12:00 a.m.7 views

Information Disclosure Vulnerability in Multiple Rockwell Automation Products

Rockwell Automation Allen-Bradley MicroLogix 1100 1763-L16AWA Series A and others are programmable logic controller PLC products from Rockwell Automation. An information disclosure vulnerability exists in multiple Rockwell Automation products. An attacker could exploit this vulnerability to recov...

9.8CVSS6.4AI score0.04021EPSS
SaveExploits0References1
CNVD
CNVD
added 2017/06/05 12:00 a.m.11 views

Unspecified Vulnerability in Multiple Rockwell Automation Products (CNVD-2017-08713)

Rockwell Automation Allen-Bradley MicroLogix 1100 1763-L16AWA Series A and others are programmable logic controller PLC products from Rockwell Automation. A security vulnerability exists in several Rockwell Automation products. An attacker could exploit the vulnerability to capture and respond to...

9.8CVSS6.9AI score0.02145EPSS
SaveExploits0References1
The Hacker News
The Hacker News
added 2017/02/16 10:14 p.m.13 views

This Ransomware Malware Could Poison Your Water Supply If Not Paid

Ransomware has been around for a few years, but in last two years, it has become an albatross around everyone's neck, targeting businesses, hospitals, financial institutions and personal computers worldwide and extorting millions of dollars. Ransomware is a type of malware that infects computers...

7.1AI score
SaveExploits0
CNVD
CNVD
added 2016/12/16 12:00 a.m.50 views

Heap Buffer Overflow Vulnerability in Multiple Delta Electronics Products

Delta Electronics WPLSoft and others are software control platforms used by Delta Electronics to edit the Delta DVP series of programmable logic controllers PLCs. A heap buffer overflow vulnerability exists in multiple Delta Electronics products. An attacker could exploit this vulnerability to...

7.8CVSS7.8AI score0.02319EPSS
SaveExploits0References1
CNVD
CNVD
added 2016/11/10 12:00 a.m.68 views

Phoenix Contact ILC Security Bypass Vulnerability

Phoenix Contact ProConOs and MultiProg are programmable logic controllers PLCs for use in industrial PCs from the Phoenix Contact group. A security bypass vulnerability exists in the Phoenix Contact ILC PLCs, which can be exploited by an unauthenticated attacker to access read and write PLC...

7.5CVSS7AI score0.14286EPSS
SaveExploits4References1
ThreatPost
ThreatPost
added 2016/08/05 4:49 p.m.64 views

PLC Blaster Worm Targets Industrial Control PLCs

LAS VEGAS – Security researchers at Black Hat USA described a proof-of-concept worm that targets weaknesses within automated industrial control systems used to manage critical infrastructure and manufacturing. The worm, according to OpenSource Security, has the capability to autonomously search f...

6.4CVSS1.6AI score0.02132EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2015/12/29 12:00 a.m.18 views

The vulnerability of microprogrammed software in programmable logic controllers PCD allows a intruder to gain administrator privileges.

The vulnerability of PCD programmable logic controllers’ microprogramming software exists due to the rigid encoding of registration data. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain administrator privileges through an FTP session...

10CVSS7.7AI score0.02449EPSS
SaveExploits0References4Affected Software10
BDU FSTEC
BDU FSTEC
added 2015/11/20 12:00 a.m.14 views

Vulnerability of microprogrammed software for Micrologix 1100 and 1400 programmable logic controllers, allowing a intruder to execute arbitrary code

The vulnerability of the microprogrammed logic controllers Micrologix 1100 and 1400 is caused by buffer overflow on the stack. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...

10CVSS6.3AI score0.07022EPSS
SaveExploits0References2
ThreatPost
ThreatPost
added 2015/02/04 10:30 a.m.13 views

Siemens ICS Switches Hit With Buffer Overflow, Authentication Bugs

There are a number of serious vulnerabilities in the Siemens Ruggedcom WIN switches, including a remotely exploitable buffer overflow and a flaw that could allow an attacker to take actions on the device without authentication. The vulnerabilities affect several models of the Ruggedcom WIN...

2.5AI score
SaveExploits0References2
ThreatPost
ThreatPost
added 2012/10/29 1:12 p.m.17 views

DHS Warns ICS, SCADA Owners About Increase in Malicious Activity

An alert from the Department of Homeland Security late last week urges private- and public-sector industrial control system ICS owners to be proactive in auditing the security, particularly, authentication controls of their systems. The alert is in response to a growing concern over the number of...

0.2AI score
SaveExploits0References6
ThreatPost
ThreatPost
added 2011/08/08 2:44 p.m.27 views

Dillon Beresford Talked Siemens Vulnerabilities

NSS researcher Dillon Beresford continued his research into the security of SCADA and industrial control systems with a talk on vulnerabilities in Siemens Step 7 programmable logic controllers. Read more: Black Hat: Remote DOS, Backdoor, Easter Egg Among Newly Discovered Siemens Holes...

2.8AI score
SaveExploits0References1
Rows per page
Query Builder