Lucene search
K

7 matches found

CNNVD
CNNVD
added 2026/03/10 12:0 a.m.5 views

Schneider Electric多款产品 跨站脚本漏洞

Schneider Electric Modicon M258 is a product of the French company Schneider Electric. Schneider Electric Modicon M258 is a programmable automation controller. Schneider Electric Modicon M241 is a programmable logic controller. Schneider Electric Modicon M251 is also a programmable logic...

5.1CVSS6AI score0.00225EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.7 views

EUVD-2019-16374

Malware in sbrugna...

8.2CVSS8.1AI score0.0124EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2024/12/11 12:0 a.m.3 views

The vulnerability of the microprogramming software for Schneider Electric’s programmable logic controllers (PLC) models M241, M251, M258, and LMC058 is related to errors in processing input data. This vulnerability allows attackers to trigger maintenance failures and compromise the confidentiality, integrity, and accessibility of protected information.

The vulnerability of the microprogrammed software of Schneider Electric’s programmable logic controllers PLC models M241, M251, M258, and LMC058 is related to errors in processing input data. Exploiting this vulnerability can allow an attacker to trigger maintenance failures and compromise the...

10CVSS5.5AI score0.00629EPSS
Exploits0References2
Prion
Prion
added 2019/05/22 8:29 p.m.23 views

Authentication flaw

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration IP address, network mask and gateway IP address when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC...

6.4CVSS8.1AI score0.0124EPSS
Exploits0References1
CVE
CVE
added 2019/05/22 7:40 p.m.84 views

CVE-2019-6820

CVE-2019-6820 describes a CWE-306 vulnerability (Missing Authentication for a Critical Function) that could allow modification of device IP configuration (IP address, netmask, gateway) when a specific Ethernet frame is received on multiple Schneider Electric Modicon/drive products. Affected produ...

8.2CVSS8.1AI score0.0124EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2019/05/22 7:40 p.m.40 views

CVE-2019-6820

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration IP address, network mask and gateway IP address when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC...

8.2AI score0.0124EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2019/05/14 12:0 a.m.7 views

PT-2019-2282

Name of the Vulnerable Software and Affected Versions Modicon M100 versions all Modicon M200 versions all Modicon M221 versions all ATV IMC drive controller versions all Modicon M241 versions all Modicon M251 versions all Modicon M258 versions all Modicon LMC058 versions all Modicon LMC078 versio...

8.2CVSS7.3AI score0.0124EPSS
Exploits0References8
Rows per page