165 matches found
CVE-2020-11607
An issue was discovered on Samsung mobile devices with P9.0 and Q10.0 software. Notification exposure occurs in Lockdown mode because of the Edge Lighting application. The Samsung ID is SVE-2020-16680 April 2020...
CVE-2020-11607
An issue was discovered on Samsung mobile devices with P9.0 and Q10.0 software. Notification exposure occurs in Lockdown mode because of the Edge Lighting application. The Samsung ID is SVE-2020-16680 April 2020...
CVE-2020-11607
CVE-2020-11607 concerns Samsung mobile devices running P(9.0)/Q(10.0). The issue is a notification exposure in Lockdown mode caused by the Edge Lighting application, enabling potential information disclosure. Affected component: Edge Lighting on affected Samsung firmware. Root cause: not explicit...
CVE-2020-11607
An issue was discovered on Samsung mobile devices with P9.0 and Q10.0 software. Notification exposure occurs in Lockdown mode because of the Edge Lighting application. The Samsung ID is SVE-2020-16680 April 2020...
Forrester: Keeping Smart Cities Safe From Hacks
SAN FRANCISCO – Municipalities today are dealing with an unanticipated number of cyberthreats, Merritt Maxim, an analyst at Forrester, said last week at the RSA Conference 2020. Local and state governments are increasingly being targeted by ransomware attacks, phishing emails and business email...
ENTTEC Lighting Controllers
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: ENTTEC Equipment: Datagate MK2, Storm 24, Pixelator Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could reboot this...
ENTTEC Lighting Controllers
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: ENTTEC Equipment: Datagate MK2, Storm 24, Pixelator Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could reboot this...
JVN#99810718: Multiple vulnerabilities in Toshiba Lighting & Technology Corporation Home gateway
Home gateway provided by Toshiba Lighting & Technology Corporation contains multiple vulnerabilities listed below. Improper access control CWE-284 - CVE-2018-16197 Version| Vector| Score ---|---|--- CVSS v3| CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L| Base Score: 6.3 CVSS v2|...
DEBIAN-CVE-2018-19628
In Wireshark 2.6.0 to 2.6.4, the ZigBee ZCL dissector could crash. This was addressed in epan/dissectors/packet-zbee-zcl-lighting.c by preventing a divide-by-zero error...
Design/Logic Flaw
In Wireshark 2.6.0 to 2.6.4, the ZigBee ZCL dissector could crash. This was addressed in epan/dissectors/packet-zbee-zcl-lighting.c by preventing a divide-by-zero error...
CVE-2018-19628
In Wireshark 2.6.0 to 2.6.4, the ZigBee ZCL dissector could crash. This was addressed in epan/dissectors/packet-zbee-zcl-lighting.c by preventing a divide-by-zero error...
lightingempire.com.au XSS vulnerability
Open Bug Bounty ID: OBB-663377 Description| Value ---|--- Affected Website:| lightingempire.com.au Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1...
CVE-2018-11681
Default and unremovable support credentials user:nwk password:nwk2 allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a...
PT-2018-10746 · Lutron · Lutron Radiora 2
Name of the Vulnerable Software and Affected Versions: Lutron RadioRA 2 versions Revision M through Revision Y Description: The issue allows attackers to gain total super user control of an IoT device through a TELNET session. Default and unremovable support credentials are used, with the usernam...
capitallightingfixture.com XSS vulnerability
Open Bug Bounty ID: OBB-583211 Description| Value ---|--- Affected Website:| capitallightingfixture.com Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1...
goldenlighting.com XSS vulnerability
Vulnerable URL: http://www.goldenlighting.com/app/site/query/getcustomermessage.nl/c.1029593/n.1/.f?=Welcome+to+IS+Custom+Uniforms%22%3E%3Csvg/onload=prompt/OPENBUGBOUNTY/%3E Details: Description| Value ---|--- Patched:| No Latest check for patch:| 19.01.2018 Vulnerability type:| XSS Vulnerabilit...
SQL Injection Vulnerability in City Lighting Wireless Control System of China Electronics Technology Group Corporation
China Electronics Technology Group Corporation CETC is a state-owned large-scale high-tech enterprise group established on the basis of electronic research institutes and high-tech enterprises directly under the former Ministry of Information Industry. A SQL injection vulnerability exists in the...
CVE-2017-0707
A elevation of privilege vulnerability in the HTC led driver. Product: Android. Versions: Android kernel. Android ID: A-36088467...
OSRAM SYLVANIA Osram Lightify Home Network Command Replay Vulnerability
OSRAM SYLVANIA Osram Lightify Home is a set of open IoT platforms for automated control of lighting devices from OSRAM Germany. A security vulnerability exists in OSRAM SYLVANIA Osram Lightify Home versions 2016-07-26 and earlier. An attacker could use the vulnerability to capture and recover...
OSRAM SYLVANIA Osram Lightify Pro Network Command Replay Vulnerability
OSRAM SYLVANIA Osram Lightify Pro is an open IoT platform for automated control of lighting devices from OSRAM Germany. A security vulnerability exists in OSRAM SYLVANIA Osram Lightify Pro 2016-07-26 and prior versions. An attacker can exploit the vulnerability to obtain and re-execute used...